Download Print this page

Specifications - Honeywell DT8016MF4 DUAL TEC Installation Instructions Manual

Motion sensor

Advertisement

SPECIFICATIONS

Range: 16 m x 22 m
Power: 9.0 - 15 VDC; 9 mA typical, 14 mA maximum, 12 VDC;
AC Ripple: 3 V peak-to-peak at nominal 12 VDC
Alarm Relay: Energized Form A; 30 mA, 25 VDC, 22 Ohms
resistance maximum. Alarm Relay Duration: 3 seconds
Trouble Relay: Energized Form B; (NC) 30 mA, 25 VDC; 22 Ohms
resistance maximum
Tampers: Cover; (NC with cover installed) Form A;
30 mA, 25 VDC; Magnetic Field
Microwave Frequencies: DT8016MF4 - 10.525 GHz
DT8016MF5 - 10.587 GHz
RFI Immunity: 15 V/m, 80 MHz – 2.7 GHz
PIR White Light Immunity: 10,000 Lux typical
Fluorescent light filter: 50 Hz / 60 Hz.
Operating Temperature: -10° to 55° C
Relative Humidity: 5 to 95%; non-condensing
Temperature Compensation: Advanced Dual Slope
Dimensions: 11.6 cm H x 7.0 cm W x 4.3 cm D
Weight: 135 g / 5 oz (net weight)
ACCESSORIES
SMB-10
Swivel Mount Bracket
(P/N 0-000-110-01)
SMB-10C
Swivel Mount Ceiling Bracket
(P/N 0-000-111-01)
SMB-10T
Swivel Mount Bracket w/Tamper
(P/N 0-000-155-01)
Note : The accessories are not covered by certifications.
APPROVAL LISTINGS
Note: In EN 50131-2-4 compliant installations, mount the sensor at 2.3m,
enable look down, set the microwave sensitivity to maximum and lock
the sensor housing with the cover lock (see "[EN]" where noted in
Steps 1-4).
IMPORTANT: The sensor should be tested at least once each year.
NF&A2P 2 boucliers (référentiel NF324-H58) et
conforme aux normes EN50131-2-4 et
RTC50131-2-4; IP30 IK04
DT8016MF4 – N° de certificat: 2821420017
DT8016MF5 – N° de certificat: 2821420018
Organisme de certification:
CNPP Cert. : www.cnpp.com et
AFNOR Cert.: www.marque-nf.com
Honeywell Security Group - BP1219
1198 avenue du docteur Maurice Donat
Sophia Antipolis
06254 Mougins Cedex.
TEL: +33.4.92.94.29.50
FAX: +33.4.92.94.29.60
Corrente norminale: 12 =
Corrente massima
assorbita: 14 mA
LARMKLASS 2
- 5 -
EN50131-2-4:2008, Security Grade 2,
Environmental Class II.
Suitable for connection to an EN 60950 Class
II Limited Power Source.
DT8016MF4
INCERT B-893-0014
DT8016MF5
PD6662:2010

Advertisement

loading

This manual is also suitable for:

Dt8016mf5 dual tec