Programming Notes
This quick start guide provides suggested programming steps only. Please customize to fit individual applications and refer to
manuals for more detail.
V32FB-9 Panel Programming
• Address the keypad
– Press 1 & 3 at keypad power up
– Set to address 01
• Enter panel programming:
– Enter 5140 800
• Default the panel
– Enter *97 followed by 1
• Program the panel – Direct Entry
– *00, enter installer code
– *17, enter 0 or 1 as required
– *19, set to 0 or 1 as required
– *32, enter dialer account number
– *33, enter C/S telephone number for dialer
– *34, enter secondary C/S telephone number if used
– *45, enter 1
– *47, enter 1
– *56, enter 00
– *58, enter 1,1,1,1,1,1 as required
– *77, enter 0 or as required
– *79, enter 1,1,1,1,1,1,1,1 as required
– *80, enter 1,1,1 as required
– *83, set test report time as needed
– *90, enter secondary account number if used
– Enter *94 to go to 100's
– 1*26, program macros if used
– 1*70, enter 1,1,1,1,1,1 to enable event buffer
– Enter *94 to go to 200's
– Enter *94 to go to 300's
– 3*00, enter 0 or 1 as required
– 3*01, enter 0 or 1 as required
– 3*12,
– 3*13, enter 0 or 1 as required
– 3*14, enter 0 or 1 as required
– 3*15, enter 0 or 1 as required
– 3*16, program delay for zone type 17 & 18 if used
– 3*18, enter 0 or 1 as required
– 3*50, enter 1,1,1 if zone types 16, 17 & 18 are used
• Program the panel – Menu Mode
– Enter #93 for menu mode
– Program zones as required
– Program report code
• Zone groups 001, 800 and 970
• Program system group 1 (AC, battery, test, etc.).
See page 23 of programming guide
– Device programming
• Program address 03 as type 06
– Quit menu mode
• Exit programming
L/V32iGSMKTF/D April 2010
iGSMCN Programming
The iGSMCN can be configured three different ways based
on the application:
1. Internet as active (GSM and Dialer optional)
2. Internet as passive (GSM or Dialer needed as second path)
3. GSM and Dialer (in cases where Internet is not present)
Use LEDs to find a location with good signal strength.
Connect a Cat5 cable from router to RJ45 connector on the
transmitter.
The iGSMCN must be registered with AlarmNet.
Test the system.
V32/iGSMKT Quick Start Guide
2

Advertisement

loading