Cisco ASR 9000 Series Configuring page 27

Configuring channelized sonet/sdh
Hide thumbs Also See for ASR 9000 Series:
Table of Contents

Advertisement

Configuring Channelized SONET/SDH on the Cisco ASR 9000 Series Router
Command or Action
Step 3
clock source {internal | line}
Example:
RP/0/RSP0/CPU0:router(config-sonet)#
clock source internal
Step 4
framing sdh
Example:
RP/0/RSP0/CPU0:router(config-sonet)#
framing sdh
Step 5
au number
Example:
RP/0/RSP0/CPU0:router(config-sonet)# au 1
Step 6
mode mode
Example:
RP/0/RSP0/CPU0:router(config-auPath)#
mode c11-t1
Step 7
root
Example:
RP/0/RSP0/CPU0:router(config-auPath)#
root
Step 8
controller t1 interface-path-id
Example:
RP/0/RSP0/CPU0:router(config)# controller
T1 0/1/1/0/0/0/0
Step 9
channel-group number
Example:
RP/0/RSP0/CPU0:router(config-t1)#
channel-group 0
OL-26061-03
Cisco ASR 9000 Aggregation Services Router Interfaces and Hardware Component Configuration Guide
Purpose
Configures the SONET port transmit clock source, where the
internal keyword sets the internal clock and the line keyword sets
the clock recovered from the line.
Use the line keyword whenever clocking is derived from the
network. Use the internal keyword when two routers are
connected back to back or over fiber for which no clocking is
available.
line is the default keyword.
Internal clocking is required for SRP interfaces.
Note
Configures the controller framing for Synchronous Digital
Hierarchy (SDH) framing.
SONET framing (sonet) is the default.
Specifies the administrative unit (AU) group and enters AU path
configuration mode. For AU-3, the valid range is:
1 to 3—1-Port Channelized OC-3/STM-1 SPA
1 to 12—2-Port Channelized OC-12c/DS0 SPA
The au command does not specify the AU type. It specifies
Note
the number of the AU group for the AU type that you want
to configure. The range for the AU command varies based
on whether you are configuring AU-3 or AU-4.
Sets the mode of interface at the AU level. AU-3 paths can be
mapped to c11-t1 or c12-e1 on supported SPAs.
Exits to global configuration mode.
Enters T1 controller configuration submode and specifies the T1
controller name and interface-path-id with the
rack/slot/module/port/auNum/t1Num notation.
Sets the channel-group number to which time slots are assigned.
The range is from 1 to 28.
How to Configure Channelized SONET/SDH