Connect remaining wires.
Depress the tabs to put the
wires into the inner holes of the
corresponding terminals on the
UWP (one wire per terminal) until it is
firmly in place.
Gently tug on the wires to verify
they are secure.
Tip: If you need to release a wire
again, push down the corresponding
terminal tab on the side of the UWP.
NOTE: Alternate wiring options are
shown on pages 11-12.
13
Confirm wiring matches snapshot.
Please confirm wiring matches terminals from the photo you took in Step 5.
14
Mount the UWP and close the door.
Mount the UWP using the provided screws. Install all three screws for a secure
fit on your wall. Close the door after you're finished.