Attaching An Ethernet Oam Profile To An Interface - Cisco NCS 5500 Series Configuration Manual

Interface and hardware component configuration
Hide thumbs Also See for NCS 5500 Series:
Table of Contents

Advertisement

Configuring Ethernet OAM
Command or Action
Step 26
action session-down {disable | efd |
error-disable-interface | log}
Example:
RP/0/RP0/CPU0:router(config-eoam)# action
session-down efd
Step 27
action session-up { disable | log }
Example:
RP/0/RP0/CPU0:router(config-eoam)# action
session-up disable
Step 28
action uni-directional link-fault {disable | efd |
error-disable-interface | log}
Step 29
action wiring-conflict {disable | efd |
error-disable-interface | log}
Example:
RP/0/RP0/CPU0:router(config-eoam)# action
session-down efd
Step 30
uni-directional link-fault detection
Example:
RP/0/RP0/CPU0:router(config-eoam)#
uni-directional link-fault detection
Step 31
commit
Example:
RP/0/RP0/CPU0:router(config-if)# commit
Step 32
end
Example:
RP/0/RP0/CPU0:router(config-if)# end

Attaching an Ethernet OAM Profile to an Interface

Perform these steps to attach an Ethernet OAM profile to an interface:
Interface and Hardware Component Configuration Guide for Cisco NCS 5500 Series Routers, IOS XR Release 6.1.x
Purpose
Specifies the action that is taken on an interface when an Ethernet
OAM session goes down.
Specifies that no action is taken on an interface when an Ethernet
OAM session is established. The default action is to create a syslog
entry.
Specifies the action that is taken on an interface when a link-fault
notification is received from the remote Ethernet OAM peer. The
default action is to create a syslog entry.
Note
In Cisco IOS XR Release 4.x, this command replaces the
action link-fault command.
Specifies the action that is taken on an interface when a wiring-conflict
event occurs. The default is to put the interface into error-disable
state.
Enables detection of a local, unidirectional link fault and sends
notification of that fault to an Ethernet OAM peer.
Saves the configuration changes to the running configuration file and
remains within the configuration session.
Ends the configuration session and exits to the EXEC mode.
Configuring Ethernet Link OAM
43

Advertisement

Table of Contents
loading

Table of Contents