Universal hot surface ignition module
Table of Contents

Advertisement

TERMINAL CROSS
REFERENCE
S8910U
50E/F47
GND(BURNER)
GND
24V (GND)
TR
VALVE (GND)
MV (NEXT TO TR)
24V
TH
VALVE
MV
L2
L1
4
L
HSI
HSI
IGN
4
SENSE
FP
BURNER
GROUND
MV
COMBINATION
GAS CONTROL
MV
1
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
MAKE SURE L1 AND L2 ARE NOT REVERSED.
2
ALTERNATE LIMIT CONTROLLER LOCATION.
3
REMOVE JUMPER QUICK-CONNECT FROM S8910U. CUT WIRE AT CIRCUIT BOARD AND DISCARD.
4
USE ADAPTER PLUG WITH BLACK AND ORANGE WIRES (SUPPLIED).
5
CUT 3/16 IN. QUICK-CONNECT OFF WIRE AND REPLACE WITH 1/4 IN. QUICK-CONNECT (SUPPLIED).
CUT 3/16 IN. QUICK-CONNECT OFF WIRE AND REPLACE WITH 3/16 IN. QUICK-CONNECT (SUPPLIED).
6
Fig. 3. Typical hookup when S8910U replaces White-Rodgers 50E/F47.
S8910U UNIVERSAL HOT SURFACE IGNITION MODULE
S8910U HOT SURFACE IGNITER CONTROL
5
6
THERMOSTAT OR
2
CONTROLLER
9
FLAME
SENSOR
3
4
ORANGE
BLACK
4
ADAPTER
LIMIT
CONTROLLER
HOT
SURFACE
IGNITER
L1
(HOT)
L2
1
M8528B
69-0845—2