Review The Installation; Frequent Cycling; Water Or Steam Cleaning - Honeywell S8910U Installation Instructions And Safety Information

Universal hot surface ignition module
Table of Contents

Advertisement

Model
Selection
Numbers
S8910U
Specifications
S89C1004
S89C1012
S89C1046
S89C1087
S89C1103
S89D1002
S89G1005
S89G1013
S89G1021
S89G1047
S89H1003
S89H1011
S89H1029
S89J1008
S890C1007
S890D1006
S890G1003
S890G1011
S890G1029
S890G1037
S890H1002
S890H1010
S890H1028
a
The S8910U and the original control lockout times are different. The S8910U lockout time is within the design tolerance
lockout time of the original control.
b
The lockout time of the S8910U is shorter than the original control. Be sure to observe the appliance operation under a
variety of input conditions to assure reliable operation.

REVIEW THE INSTALLATION

WARNING
FIRE OR EXPLOSION HAZARD.
CAN CAUSE PROPERTY DAMAGE,
SEVERE INJURY, OR DEATH.
Follow these warnings exactly:
1. Review the installation as outlined in this
section.
2. Plan for frequent maintenance as described in
the Maintenance section.
When hot surface ignition systems are used on central
heating equipment in barns, greenhouses, and commercial
properties and on heating appliances such as commercial
cookers, agricultural equipment, industrial heating
equipment and pool heaters, heavy demands are made on
the controls. Special steps can be required to prevent
nuisance shutdowns and control failure due to frequent
cycling, severe environmental conditions related to
Table 3. Honeywell Control to Honeywell S8910U Cross Reference.
S8910U
Remove
Local (L) or
Black
Remote (R)
Tab
Jumper
A
B
C
D
C
No
C
No
A
No
C
No
A
No
C
Yes
B
No
D
No
D
No
D
No
B
Yes
D
Yes
D
Yes
C
No
C
No
C
Yes
B
No
D
No
D
No
D
No
B
Yes
D
Yes
D
Yes
S8910U UNIVERSAL HOT SURFACE IGNITION MODULE
Lockout
Time
Sensing
(sec)
4
Local or
Remote
7
a
L
6
a
L
6
L
4
a
L
6
L
4
a
R
6
L
4
a
L
6
b
L
11
a
L
6
R
4
a
R
6
b
R
11
a
L
6
a
L
6
a
R
6
L
4
a
L
6
b
L
11
a
L
6
R
4
a
R
6
b
R
11
moisture, corrosive chemicals, dust or excessive heat.
These applications require Honeywell Home and Building
Control Engineering review; contact your Honeywell Sales
Representative for assistance.
Review the following conditions that can apply to your
specific installation and take the precautionary steps
suggested.

Frequent Cycling

These controls are designed for use on appliances that
typically cycle only three to four times an hour during the
heating season. In year-round applications with greater
cycling rates, the control can wear out more quickly.
Perform a monthly checkout.

Water or Steam Cleaning

If a module or gas control gets wet, replace it. If the
appliance is likely to be cleaned with water or steam, cover
the controls and wiring to protect from water or steam flow.
5
Ignition
PrePurge
Warmup
Trials
(sec)
1
32
3
1
3
1
0
1
0
1
0
1
0
1
0
1
0
3
0
3
0
3
0
3
0
3
0
3
0
3
0
1
0
1
30
1
30
3
30
3
30
3
30
3
30
3
30
3
30
3
30
Igniter
Between
Trial Purge
(sec)
(sec)
34
NA
96
NA
96
34
NA
34
NA
34
NA
34
NA
34
NA
34
NA
34
30
34
30
34
30
34
30
34
30
34
30
34
30
34
NA
34
NA
34
NA
34
30
34
30
34
30
34
30
34
30
34
30
34
30
69-0845—2