Sira Approved Version - GE Masoneilan 4700P Maintenance Manual

Pneumatic and electropneumatic positioners
Table of Contents

Advertisement

SIRA Approved Version

Installation must be in accordance with current applicable country codes and manufacturer's in-
structions.
Maximum pressure 150 PSI.
Intrinsically
Safe
WARNING
For flameproof (Ex d protection concept):
The marking of the equipment shall include the following:
For intrinsically safe (Ex ia protection concept):
38 | =GE Oil & Gas
Installation must be in accordance with current editions of applicable
country codes, Figure 15 on page 42, and manufacturer's instruc-
tions. Housing protection rating IP 66.
Do not open when energized. Do not open when an explosive gas
atmosphere is present. Use cables rated to 5 °C above ambient.
Sira 02ATEX1274
II 2GD
Ex d IIC T6 Gb
Ex d IIC T5 Gb
Ex d IIC T4 Gb
Ex t IIIC T90 ° Db
Sira 02ATEX2277X
II 1GD
Ex ia IIC T4 Ga
Ex ia IIC T6 Ga
T
= -40 °C to +55 °C
a
T
= -40 °C to +70 °C
a
T
= -40 °C to +85 °C
a
T
= -40 °C to +55 °C
a
T
= -40 °C to +80 °C, P
a
T
= -40 °C to +55 °C, P
a
© 2015 General Electric Company. All rights reserved
= 1.1 W
i
= 0.33 W
i
.