Download Print this page

Honeywell ADEMCO 4100SM Installation And Setup Manual page 3

Serial interface module

Advertisement

NOTES:
1.
If Earth Ground Fault Sensing is enabled in the control
panel you may get an earth ground fault indication if
you use a printer (or PC) which has a 3 prong grounded
power cord.
2.
The 4100SM is supplied with a 10-foot RS-232 cable. A
longer cable or extension cable can be used if the
4100SM and the printer are separated by more than 10
feet, but the total cable length should be less than 50
feet.
3.
Most printers either ignore the CTS, DSR and CD
signals, or require them to be high (i.e., 3-15VDC as
measured on RS-232 DB25 connector pins 5, 6, & 8
respectively with respect to ground pin 7). The 4100SM
Module sets these pins high. If the printer being used
will not operate with these pins high, then clip the blue
(CTS), white (DSR) or red (CD) jumpers on the 4100SM
module to set the corresponding signal floating.
Important pins on the RS-232 cable are pin 3 (data out),
pin 7 (ground), and pin 20 (DTR - ready).
1
2
3
4
5
6
7
NU
4100SM JUMPERS
(CUT TO SET RESPECTIVE SIGNAL FLOATING)
COLOR
FUNCTION
PIN #
RED
CD
BLUE
CTS
WHITE
DSR
Figure 4. Printer Connections for VISTA-BP and FA1660C
Control Panels
1
2
3
4
5
6
7
4100SM JUMPERS
(CUT TO SET RESPECTIVE SIGNAL FLOATING)
COLOR
FUNCTION
PIN #
RED
CD
8
BLUE
CTS
5
WHITE
DSR
6
Figure 5. Printer Connections for VISTA-FBP, FA1670C
and FA1700C Control Panels
8
9
J8 CONNECTOR
4142TR CABLE (SUPPLIED WITH 4100SM)
4100SM SERIAL MODULE
To TB6 Aux. Power (+)
8
+ PWR
(25mA current draw)
To TB7 Aux. Power (-)
7
- (GND)
6
RXD
5
not used
4
not used
3
TXD
2
not used
1
DTR
RED
BLUE
WHITE
USE GENDER CHANGER
3M
Cable
(NOT SUPPLIED) WITH
Supplied with
4100SM IF PRINTER HAS
4100SM
DB25 MALE CONNECTOR
SERIAL PRINTER
SET FOR: 8 DATA BITS
8
EVEN PARITY
5
STOP BIT
6
300/1200 BAUD
8
9
J2 CONNECTOR
4142TR CABLE (SUPPLIED WITH 4100SM)
4100SM SERIAL MODULE
To TB11 Aux. Power (+)
8
+ PWR
(25mA current draw)
7
- (GND)
To TB12 Aux. Power (-)
6
RXD
5
not used
4
not used
3
TXD
2
not used
1
DTR
RED
BLUE
USE GENDER CHANGER
3M
Cable
(NOT SUPPLIED) WITH
Supplied with
4100SM IF PRINTER HAS
4100SM
DB25 MALE CONNECTOR
SERIAL PRINTER
SET FOR: 8 DATA BITS
EVEN PARITY
STOP BIT
300/1200 BAUD
Home/Facility Automation Connections
The 4100SM can be used to connect the control panel to 3rd
party Home/Facility Automation hardware and software.
The 4100SM connects to the control panel's circuit board via
the supplied 4142TR voltage trigger cable. As shown in
Figures 6 and 7, terminals 3, 6, 7, and 8 on the 4100SM are
used.
NOTES:
1.
The distance between the 4100SM and the control panel
cannot exceed the length of the 4142TR Trigger Cable.
2.
The maximum distance between the 4100SM and the
3rd party Home/Facility Automation hardware is 50'. If
shielded wire, wire in conduit, or Cat 5 unshielded is
used, the maximum distance is 25'.
CONTROL PANEL
J8 CONNECTOR
Figure 6. Home/Facility Automation Connections for
CONTROL PANEL
J2 CONNECTOR
WHITE
Figure 7. Home/Facility Automation Connections for
VISTA-FBP, FA1670C and FA1700C Control Panels
-3 -
4142TR CABLE (SUPPLIED WITH 4100SM)
BLACK
GROUND
BLUE
GROUND
BROWN
OUT 6
GREEN
OUT 5
RED
GROUND
YELLOW
IN 3
GREY
VIOLET
IN2
PRINTER DTR
(ZONE 9)
AUX GND.
AUX PWR.
VISTA-BP and FA1660C Control Panels
4142TR CABLE (SUPPLIED WITH 4100SM)
VIOLET
GREY
YELLOW
WHITE
RED
GREEN
BROWN
BLUE
BLACK
AUX GND.
AUX PWR.
4100SM
SERIAL
MODULE
8
+ PWR
- (GND)
7
6
RXD
5
NOT USED
4
NOT USED
3
TXD
2
NOT USED
1
DTR
RED
BLUE
WHITE
TO
AUTOMATION
EQUIPMENT
(RS232 INTERFACE)
4100SM-013-V1
4100SM
SERIAL
MODULE
8
+ PWR
- (GND)
7
RXD
6
5
NOT USED
4
NOT USED
TXD
3
2
NOT USED
1
DTR
RED
BLUE
WHITE
TO
AUTOMATION
EQUIPMENT
(RS232 INTERFACE)
4100SM-015-V1

Advertisement

loading