Simple P/P Software; Overview; Restrictions On Use - Sony MVS-6000 User Manual

Multi format switcher system with ccp-9000 series center control panel
Hide thumbs Also See for MVS-6000:
Table of Contents

Advertisement

Simple P/P Software

Overview

By installing the BZS-6250 Simple P/P Software in the MVS-6000 Switcher
Processor, you can use a separate program/preset function without using the M/
E hardware.
Getting access to the software
To use the Simple P/P Software, you are required to enter an install key which
validates the software. (If the software has been factory installed, the install key
is not required.)
For the method of obtaining an install key, contact your Sony representative.
On that occasion, you may be required to submit the unique device ID of the
switcher you are using. You can check the unique device ID in the Install menu
of the switcher. For details of operating procedures, see "Installation and
Device Setup (Install/Unit Config Menu)" in Chapter 18 (Volume 3).

Restrictions on Use

Since this software is a simple version of the program/preset function, there are
some restrictions on use. The following lists the points at which operation is
different from a normal program/preset function. For details of the normal
operations, set the relevant sections of this manual.
Restrictions on using a downstream key
• DSK3 and DSK4 cannot be used.
For the key priority, set priority 1 or priority 2.
• The following downstream key types cannot be used.
– Chroma key
– Color vector key
– Key wipe pattern key
• When using a matte as the key fill for a downstream key, a mix color cannot
be used.
• It is not possible to modify a downstream key edge. The edge blink also
cannot be used.
• For a downstream key, mask cannot be used.
357

Simple P/P Software

Advertisement

Table of Contents
loading

Table of Contents