NOTE: If Navigator 2 cannot access the AMS 2100/2300 array, the array
may be turned off or there may be a network failure between Navigator 2
and the array.
4. If you received an email about the failure or used SNMP to detect the
failure, check that the hardware serial number in the email/SNMP
matches the one on The AMS 2100/2300 array (see
page
5. Check the status column of the system that matches the hardware serial
number checked in the previous step.
Normal = The AMS 2100/2300 array is operating normally. The
fault may have occurred between the array and the host. See "A
failure other than an array failure occurs" in
and Solutions, on page
Navigator 2 cannot access the AMS 2100/2300 array. The MAIN
SW switch may be set to the OFF position or a network failure may
have occurred between the host and the array. See "Navigator 2
cannot communicate with the array" in
Solutions, on page
6. From the Arrays area shown in
of the array. When the next screen appears, click either Alerts &
Events in the Array List window or Check for Errors in the Common
Array Tasks area. In the Alert Parts tab, check for the failed part, such
as a disk drive (see
If a disk drive is shown, replace the drive. See
in chapter 9.
If the AMS 2100/2300 array is shown, the array is faulty and
should be replaced.
If neither appears in the failure list window, a software failure may
have occurred. See
1:Problems and Solutions, on page
8–12
8-11).
8-2.
Figure
An unidentified failure has occurred
Figure 8-4: Example of the Failure Parts List Tab
Troubleshooting
Hitachi AMS 2100/2300 Storage System Hardware Guide
8-2.
Table 8-1:Problems and
Figure 8-3 on page
8-4).
8-2.
Figure 8-3 on
Table 8-1:Problems
8-11, click the name
Adding a disk drive
in
Table 8-