Specifications S4565Ad, Bd, Cd, Dd, Pd, Qd, Rd, Sd, Td "2000" Series - Honeywell S4565 Production Handbook

Ignition controls for combined valve and ignition system
Hide thumbs Also See for S4565:
Table of Contents

Advertisement

SPECIFICATIONS
Model
Suffix AD:
atmospheric, direct burner ignition
Suffix BD:
as AD but with flame relay output
Suffix CD:
fan assisted, direct burner ignition
Suffix DD:
as CD but with flame relay output
Suffix PD:
as AD except volatile lock-out
Suffix QD:
as BD except volatile lock-out
Suffix RD:
as CD except volatile lock-out
Suffix SD:
ignition circuit and rectifier only
Suffix TD:
as DD except volatile lock-out
Supply voltage
230 ... 240 Vac, 50/60 Hz
Power consumption
4 VA
Humidity
90% RH max. at 40°C
Ambient temperature
-15 ... 60°C
Electrical rating (see also note 13.)
Alarm:
230 ... 240 Vac, 50/60 Hz,
output max 1mA (e.g. neon light with
internal resistor > 150 kΩ)
Fan:
230 ... 240 Vac, 50/60 Hz,
max 1 A, max cos ϕ > 0.6
Hour counter:
230 ... 240 Vac, 50/60 Hz,
max 1 A, cos ϕ > 0.6
Flame relay contact: 230 ... 240 Vac, 50/60 Hz,
max 1 A, cos ϕ > 0.6
Flame opto coupler: +5 V, 10 kΩ
Electrical connection
High voltage spark: 2.8 mm spade terminal
optional:
4 mm round terminal in spark to ground
application
Flame sensing:
4.8 mm spade terminal
PCB connectors:
Molex 3003 series suitable for
Molex 3001 female cable connector
S4565AD, BD, CD, DD, PD, QD, RD, SD, TD "2000" SERIES
Housing (degree of protection)
See:
accessories for degree of protection page 7..
replacement parts and accessories page 66..
Timing (depending on O.S. number)
Self check time (T
):
c
Waiting time (T
):
w
Safety time (T
):
s
Extended spark ignition time:
Flame sensing
Min flame current:
for optional phase independent systems:0.5 µA
for phase dependent systems: 0.9 µA
Response time on:
Response time off (T
FR
Ignition
Spark voltage:
Spark energy:
Repetition rate:
Max. spark gap:
Length flame sensing cable
1 m max.
Length ignition cable
0.5 m max.
Length of wiring for external components
1 m max.
Remark
Optional integrated flame relay available with safe separation
or opto coupler with safe separation.
N.C. contact of flame relay has no safe separation.
WARNING
Opto coupler interface needs a debounce time > 20
ms in order to prevent noise caused by transients on
mains.
25
0 ... 2 s
0 ... 30 s
3.5 ... 55 s
0 ... T
s
(depending on elaps of safety time)
> 0.2 s
):
< 1 s
(optionally other values available)
> 12 kV at 40 pF load
(depending on O.S. number)
3 ... 15 µAs
2.5 ... 60 Hz
(depending on O.S. number)
3.5 mm
EN2R-9031 0402R15-NE