2. FUNCTION SETTINGS

2-4. List of memory switch settings

Note: Regarding the term "work clamp" in the table
Normally the intermittent presser foot is lifted and dropped at the same time the work clamp is lifted and dropped.
However, the intermittent presser foot can be set not to operate by means of settings such as the setting for memory
switch No. 54.
Setting
No.
value
Work clamp lift timing after sewing is completed
001
OFF
ON
Integrated-type work clamp drop operation
0
002
1
2
Sewing start speed
OFF
100
ON
Single-stitch test feed
OFF
200
ON
Production counter display
300
OFF
ON
User programs
400
OFF
ON
Cycle programs
401
OFF
ON
Maximum reduction ratio (mm display) (*2)
402
OFF
ON
Split mode selection
0
403
1
2
*1
The position of the work clamp stopper must be set. (Refer to the Instruction Manual.)
*2
The mm display may differ slightly from the actual sewing size.
5
Lifts at the final stitch position.
Lifts after moving to the sewing start position.
Work clamp dropping in 1 step
Work clamp dropping in two steps (*1)
Do not use this setting.
The sewing speed for the first 1 to 5 stitches is set by memory switch numbers 151
to 155.
1st stitch at 400 rpm, 2nd stitch at 400 rpm, 3rd stitch at 600 rpm, 4th stitch at 900
rpm, 5th stitch at 2,000 rpm
Test feed starts when the start switch is depressed, and it continues automatically
until the final stitch.
Test feeding
・ Is carried out one stitch at a time each time the work clamp switch is
depressed
・ Is carried out continuously while the start switch is depressed
・ Is carried out one stitch at a time when the pulley is turned by hand
Lower thread counter display
Production counter display
Disabled
User program mode is enabled.
Disabled
When sewing user programs, the set programs are sewn in numeric order.
Displayed as %.
Displayed as mm.
Continuous split (split menu is disabled before split detection)
Continuous split (split menu is always enabled)
Independent split
Setting item
BAS-342G
Default
value
ON
0
OFF
OFF
OFF
OFF
OFF
OFF
0