Filler Card
Filler cards are designed to occupy empty multiservice and AIC-I slots in the Cisco ONS 15454 (Slots 1-6, 9,
and 12 - 17). The filler card cannot operate in the XC slots (Slots 8 and 10) or TCC slots (7 and 11). When
installed, the filler card aids in maintaining proper air flow and EMI requirements.
Note: There are two types of filler cards, a detectable version (Cisco P/N 15454-FILLER) and a
non-detectable version (Cisco P/N 15454-BLANK). The detectable card has the label FILLER on the
faceplate. The non-detectable card has no faceplate label. In Software Release 6.0 and greater, the former
card is detectable through CTC when installed in the ONS 15454 shelf.
Figure 1-36 shows the faceplate of the detectable filler card. The filler cards have no card-level LED
indicators.
Figure 1-36: Detectable Filler Card Faceplate
Table 1-24: Pin Association for Alarm Output Pins
N.C.
42
COM_11
43
NO_11
44
N.C.
45
COM_13
46
NO_13
47
N.C.
48
COM_15
49
NO_15
50
N.C.
51
NO_0
52
COM_10
N.C.
NO_12
COM_12
N.C.
NO_14
COM_14
N.C.
N.C.
GND1
GND2
47