Programming the Lyric Gateway (Continued)
Programming the
Programming the
Programming the
Enrolling
Enroll
Enroll
Enroll
ing
ing Wireless Sensors
ing
Wireless Sensors
Wireless Sensors
Wireless Sensors
The Lyric Gateway supports 5800 series and SiX™ Series wireless sensors that can be enrolled via AlarmNet
360. An overview of the programming fields and options, as viewed via the AlarmNet 360 App is provided
below. Refer to the Lyric Gateway Installation and Reference Guide for additional information.
Add Sensor
1
Zone number
*
3
RF 5800
2
Sensor Type
3
4
Serial #
*
Enter Serial Number
5
Loop # / Service
1
6
Device Type
Window
7
Response Type
Perimeter
Arm Night
8
9
Alarm Report
10
Enter Zone Descriptor
Description 1
11
Description 2
Enter Zone Descriptor
12
Supervision
RF Supervised
Standard
13
Chime
Save
Enrolling
Enroll
ing Key fobs (
Key fobs (Wireless
Wireless Key
Enroll
Enroll
ing
ing
Key fobs (
Key fobs (
Wireless
Wireless
The Lyric
Gateway
supports 5800 series and SiX Series wireless key fobs that can be enrolled via AlarmNet 360.
Add new Keyfob
1
Type
5800
2
No. of Keys
4 Button Key
User Name
*
- - Select User - -
3
4
Serial #
*
5
Available Starting Zones
131
Learn Keyfob
6
7
Serial #
Button 1
8
9
Zone number
131
10
Loop Number
3
11
Button Action
Arm Away
Save
Enrolling Wireless Keypads
Enrolling Wireless Keypads
Enrolling Wireless Keypads
Enrolling Wireless Keypads
The Lyric Gateway supports Lyric Keypads. Up to 8 wireless keypads can be enrolled via AlarmNet 360.
Add Keypad
1
Zone number
850
SiX Keypad
TM
2
Keypad Type
3
Serial # / MAC
*
Learn Keypad
4
5
Version
SA : 0
Enter Zone Descriptor
6
Description 1
7
Description 2
Enter Zone Descriptor
Supervision Interval
8
60Min
Save
Deleting Wireless
Deleting Wireless Sensors
Deleting Wireless
Deleting Wireless
Sensors
Sensors
Sensors, Keys and K
Refer to Deleting Wireless Sensors, Keys and Keypads in the Lyric Gateway Installation and Reference Guide.
Lyric Gateway (Continued)
Lyric Gateway (Continued)
Lyric Gateway (Continued)
Learn Sensor
2
3
4
Save and Add Another
Keys s s s ) ) ) )
Key
Key
Save and Add Another
Save and Add Another
, Keys and K
, Keys and Keypads
, Keys and K
eypads
eypads
eypads
Index
Index
Index
Index
Field
Field
Field
Field
1
Zone Number *
Select Zone Number to Enroll OR Enroll the
next available Zone Number
2
Sensor Type
Select RF 5800 OR SiX
3
Learn Sensor
Enroll the Sensor via RF Learning
4
Serial # *
Manually Enter the Device Serial Number
5
Loop # /
Select Loops 1-4 for RF 5800 devices OR
Service
SiX = Reed, External
6
Device Type
Select from the Device Type from the available
options (Refer to the Device/ Response Type
Matrix for a list of available Device Types)
7
Response Type
Select from the available Response Type
options. The Response Types are dependent
upon the Device Type selected. (Refer to the
Device/ Response Type Matrix for a list of
available Response Types)
8
Night Stay
Enable or Disable Night Stay mode
(Displayed if Device Type Motion Sensor or
Other is selected. Requires selection of Interior
Follower or Interior With Delay Response Type)
9
Alarm Report
Enable or Disable Alarm Report option
10
Description 1
Enter a Zone descriptor
11
Description 2
Enter a Zone descriptor
12
Supervision
Select RF Supervised or RF Unsupervised
13
Chime
Select a Chime sound from the available
options. (Refer to the Chime Table for a list of
available Chime sounds)
Index
Index
Index
Index
Field
Field
Field
Field
1
Type
Select Type of Keyfob 5800 OR SiX
2
No. of Keys
Select Keyfob (1 Button Key, 2 Button Key, 4, , , ,
6 Button Key, 8 Button Key)
3
User Name *
Select a User from the programmed list
4
Serial # *
Manually Enter the Keyfob Serial Number
5
Available
Select a Keyfob Zone from the available zone
Starting Zones
list
6
Learn Keyfob
Enroll the Key Fob via RF Learning
7
Serial #
Manually Enter the Device Serial Number
8
Button
Variable depending upon Keyfob Type
selected
9
Zone number
Next available zone is displayed
10
Loop Number
Variable depending upon Keyfob Type
selected (Loop 1 -4)
11
Button Action
Program the button action
Index
Index
Index
Index
Field
Field
Field
Field
1
Zone Number
Next available Keypad Zone Number is
displayed. This field is not programmable.
2
Keypad Type
Keypad Type is displayed. This field is not
programmable.
3
Serial # / MAC *
Manually Enter the Keypad Serial / MAC
Number
4
Learn Keypad
Enroll the Keypad via RF Learning
5
Version
Displays Keypad Software version
6
Description 1
Enter a Zone descriptor
7
Description 2
Enter a Zone descriptor
8
Supervision
Supervision Time Interval is not
Interval
programmable.
- 3 -
Description
Description
Description
Description
Description
Description
Description
Description
Description
Description
Description
Description

Advertisement

loading

This manual is also suitable for:

Lyric lcp300-lc