Transmitter Type and Model
Draft Range
STD110
Differential Pressure
STD125
STD120, STD130, STD170
STD904, STD924, STD930,
STD974
Gauge Pressure
STG140, STG170, STG180
STG14L, STG17L, STG18L,
STG19L
STG14T
STG93P
STG944, STG974
STG90L, STG94L, STG97L,
STG99L
STG98L,
~
Transmitter Type
Draft Range
Differential Pressure
Gauge Pressure
Absolute Pressure
3 of 4
Exhibit A –Additions to Table 4
Ambient Temperature
°C
-40 to 70
-40 to 85
-40 to 85
-40 to 85
-40 to 85
-40 to 85
-40 to 85
-15 to 65
-40 to 85
-40 to 85
~
Exhibit B –Additions to Table 5
Upper Range Limit (URL)
10 inches H
O (25 mbar)
2
400 inches H
O (1 bar)
2
100 psi (7 bar)
3000 psi (210 bar)
100 psi (7 bar)
300 psi (21 bar)
500 psi (35 bar)
3000 psi (210 bar)
6000 psi (415 bar)
10000 psi (690 bar)
780 mmHg Absolute
(1 bar)
500 psia (35 bar)
34-ST-99-12 Addendum
Process Interface Temperature
°F
-40 to 158
-40 to 70
-40 to 185
-40 to 85
-40 to 185
-40 to 125
-40 to 185
-40 to 125
-40 to 185
-40 to 125
-40 to 185
-40 to 110
-40 to 185
-40 to 150 †
5 to 149
-15 to 95 ††
-40 to 185
-40 to 125
-40 to 185
-40 to 110
~
Maximum Working
Pressure Rating
50 psi (3.5 bar)
3000 psi (210 bar)
3000 psi (210 bar)
3000 psi (210 bar)
100 psi (7 bar)
300 psi (215 bar)
500 psi (35 bar)
3000 psi (210 bar)
6000 psi (415 bar)
10000 psi (690 bar)
780 mmHg Absolute
(1 bar)
500 psia (35 bar)
°C
°F
-40 to 158
-40 to 185
-40 to 257
-40 to 257
-40 to 257
-40 to 230
-40 to 302 †
5 to 203 ††
-40 to 257
-40 to 230
~
~
Overpressure Rating
50 psi (3.5 bar)
(No overpressure
protection is provided)
3000 psi (210 bar)
3000 psi (210 bar)
3000 psi (210 bar)
150 psi (10.3 bar)
450 psi (31 bar)
750 psi (52 bar)
4500 psi (310 bar)
9000 psi (620 bar)
15000 psi (1034 bar)
Full vacuum to 1550
mmHg Absolute (2 bar)
750 psia (52 bar)