Summary of Contents for iHealth BP5

  • Page 1: Table Of Contents

    CARE AND MAINTENANCE Wireless Blood Pressure Monitor (BP5) WARRANTY INFORMATION EXPLANATION OF SYMBOLS OWNER’S MANUAL IMPORTANT INFORMATION REQUIRED BY THE FCC Table of Contents OTHER STANDARDS AND COMPLIANCES ELECTROMAGNETIC COMPATIBILITY INFORMATION INTRODUCTION PACKAGE CONTENTS INTENDED USE BLOOD PRESSURE CLASSIFICATION FOR ADULTS...
  • Page 2: Owner's Manual

    INTRODUCTION BLOOD PRESSURE CLASSIFICATION FOR ADULTS Thank you for selecting the iHealth Wireless Blood Pressure Monitor. The iHealth Wireless Blood The World Health Organization (WHO) has created the following guide for assessing high blood Pressure Monitor is a fully automatic arm cuff blood pressure monitor that uses the oscillometric pressure (without regard to age or gender).
  • Page 3: Parts And Display Indicators

    4 device to detect the Bluetooth signal. iPhone 3GS • Each subsequent time you use the monitor "Not Connected" will be displayed next to “BP5 iPad (3rd generation) xxxxxx” in the Bluetooth Menu. Tap to re-establish the connection. iPad 2 iPad Note: Please repeat step 1 when you switch an iOS device.
  • Page 4: Measurement Procedures

    MEASUREMENT PROCEDURES Body Posture Sitting During Measurement Apply the Cuff 1/2”(1-2cm) a. Be seated with your feet flat on the floor without crossing your legs. a. Pull the cuff end through the metal loop, positioning it outward b. Place your hand palm-side up in front of you on a flat surface such as a desk or table. (away from your body).
  • Page 5: Specifications

    “START/STOP” button. The status indicator light will be green and the monitor will begin measure- Battery: 1*3.7V Li-ion 400mAh ment. If measured successfully, the measurement will be stored in the iHealth Wireless Blood 10. Measurement range: Pressure Monitor and the status indicator light will flash green. The reading is not visible until the Cuff pressure: 0-300 mmHg next iOS connection.
  • Page 6: General Safety And Precautions

    11. Accuracy: This Wireless Blood Pressure Monitor is designed for adults and should never be used on Pressure: ±3 mmHg infants, young children, pregnant or pre-eclamptic patients. Consult your physician before Pulse rate: ±5% use on children. 4. Do not use this product in a moving vehicle as this may result in inaccurate measurements. 12.
  • Page 7: Battery Handling And Usage

    60601-1 and IEC 60601-1-2/EN 60601-1-2 is suitable for this monitor, such as Note: The battery has limited charge cycles and may eventually need to replaced by an iHealth ASP5-05010002JU (input: 100-240V, 50/60Hz, 200mA; output: DC 5V, 1.0A). Please note service provider.
  • Page 8: Troubleshooting

    Please see GENERAL SAFETY AND your warranty and possibly damage your unit. PRECAUTIONS. 11. Cuff replacement should only be performed by a qualified iHealth technician. To do otherwise No response Incorrect operation or strong electromagnetic Press the START/STOP button about 10 seconds to reset will possibly damage your unit.
  • Page 9: Warranty Information

    WARRANTY INFORMATION Symbol for "SERIAL NUMBER" The iHealth Wireless Blood Pressure Monitor is warranted to be free from defects in materials and workmanship within one year from the date of purchase when used in accordance with the provided instructions. The warranty extends only to the end user. We will, at our option, repair Symbol for "KEEP DRY"...
  • Page 10: Important Information Required By The Fcc

    Part 15 of the FCC Rules. These limits are designed to provide reasonable protection and any use of such marks by iHealth Lab Inc. is under license. Other trademarks and trade names are those of their respective owners.
  • Page 11: Other Standards And Compliances

    OTHER STANDARDS AND COMPLIANCES ELECTROMAGNETIC COMPATIBILITY INFORMATION The Wireless Blood Pressure Monitor corresponds to the following standards: Table 1 IEC 60601-1:2006 (Medical electrical equipment – Part 1: General requirements for safety); For all ME EQUIPMENT and ME SYSTEMS IEC 60601-1-2:2007 (Medical electrical equipment – Part 1: General requirements for safety; Guidance and manufacture’s declaration - electromagnetic emissions Collateral Standard-Electromagnetic compatibility - Requirements and tests);...
  • Page 12 IEC 61000-4-5 line(s) line(s) commercial or hospital environment. used no closer to any part of the BP5, including cables, than the ± 2 kV line(s) to earth ± 2 kV line(s) to earth recommended separation distance calculated from the <5 % U...
  • Page 13 0.23 location in which the BP5 is used exceeds the applicable RF compliance level above, the BP5 should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocating the BP5.