Figure 11-4 Viewing All Alarms Reported For Current Session; Table 11-7 History Column Description - Cisco ONS 15600 Reference Manual

Hide thumbs Also See for ONS 15600:
Table of Contents

Advertisement

11.2.5 History Window
Figure 11-4
Table 11-7
Table 11-7
Column
Num
Ref
Date
Object
Sev
Eqpt Type
ST
Description
Port
Cond
Slot
SA
Cisco ONS 15600 Reference Manual, R6.0
11-8
Viewing All Alarms Reported for Current Session
describes the information in the History window.
History Column Description
Information Recorded
An incrementing count of alarm or condition messages. (The column is hidden by
default; to view it, right-click a column and choose Show Column > Num.)
The reference number assigned to the alarm or condition. (The column is hidden by
default; to view it, right-click a column and choose Show Column > Ref.)
Date and time of the alarm
TL1 AID for the alarmed object
Severity level: CR, MJ, MN, NA, NR
Card type in this slot (only displays in network view and node view)
Status: R, C, T
Description of the condition
Port where the condition occurred
Condition name
Slot where the condition occurred (only displays in network view and node view)
When checked, indicates a service-affecting alarm