AP-7161 Access Point Installation Guide
Parameter
Nominal Output Voltage
Operating Temperature
Storage Temperature
PoE Interface Connections
Input (Data In) Ethernet 10/100/1000Base T
Output (DATA PWR OUT) Ethernet 10/100/1000Base T, +55 VDC
Power cable
Installing the PoE Unit
When making connecting the PoE unit to the AP-7161 GE1/POE port, a properly rated RJ45 connector is required. Tighten the
connectors to create a weatherproof seal.
To connect the PoE unit to the access point:
Connect the DATA IN jack to the GE1/POE connector.
1•
Connect the PoE unit to a 100-240 VAC outlet.
2.
To mount the PoE Unit:
Mount the unit as required for an AP-7161 pole or wall mount installation.
1•
Connect the earth ground cable to the unit and properly connect the cable to an external ground.
2.
-40 to -55 degrees C / -40 to 131 degrees F for 30 Watts
-40 to -65 degrees C / -40 to 149 degrees F for 15.4 Watts
-20 to 85 degrees C / -40 to -185 degrees F
Port
Description
54 to 57 VDC
RJ45 female socket
RJ45 female socket
with DC voltage on wire pairs 1-2, 3-6, 4-5 and 7-8.
Pre-installed 5m power cable with main plug.
Connector