32Z07617.book 46 ページ 2012年7月31日 火曜日 午後3時21分
Before storing the unit for an extended period:
1.Be sure the storage area is free of excessive humidity and dust.
2.Drain the fuel.
Gasoline is extremely flammable and is explosive under certain 
conditions. Perform this task in a well ventilated area with the engine
stopped. Do not smoke or allow flames or sparks in the area during
this procedure.
a. Unscrew the fuel filler cap and
remove the fuel filter.
b. Drain all gasoline from the fuel tank
into an approved gasoline container.
We recommend using a commercially
available gasoline hand pump. Do not
use an electric pump.
c. Turn the engine switch to the ON position, and loosen the 
carburetor drain screw and drain the gasoline from the carburetor
into a suitable container.
d. With the drain screw loosened remove the spark plug cap, and pull
the starter grip 3 to 4 times to drain the gasoline from the fuel
pump.
e. Turn the engine switch to the OFF position, and tighten the drain
screw securely.
f. Reinstall the spark plug cap on the spark plug securely.