1.TROUBLESHOOTING FOR THE HARDWARE
3
Close the cover under the receiving tray.
4
Close the covers of the finisher and the Hole Punch Unit (when it is installed) first, and connect
the finisher to the equipment.
Move the finisher slowly placing your hands on the positions shown in the figure.
Be careful not to let your fingers be caught between the finisher and the equipment.
This could injure you.
 Bridge unit
Do not touch the metal parts or motors of the bridge unit.
You could be burned or the shock could cause an injury to your hand.
Remove the misfed paper from the bridge unit after clearing all the other misfeeds.
You must remove other misfed paper from the equipment before clearing paper from the bridge unit. Pulling the
bridge unit off the equipment without removing the misfed paper may cause the paper to be torn and left inside the
equipment.
1
Close the Accessory Tray when it is installed.
44 Clearing a Paper Misfeed