GE M60 UR Series Instruction Manual page 519

Motor protection system
Table of Contents

Advertisement

APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 38 of 66)
ADDR
REGISTER NAME
81CC
Reserved Register T8
EGD Fast Production Status (Read Only Non-Volatile)
83E0
EGD Fast Producer Exchange 1 Signature
83E1
EGD Fast Producer Exchange 1 Configuration Time
83E3
EGD Fast Producer Exchange 1 Size
EGD Slow Production Status (Read Only Non-Volatile) (2 Modules)
83F0
EGD Slow Producer Exchange 1 Signature
83F1
EGD Slow Producer Exchange 1 Configuration Time
83F3
EGD Slow Producer Exchange 1 Size
83F4
...Repeated for module number 2
EGD Fast Production (Read/Write Setting)
8400
EGD Fast Producer Exchange 1 Function
8401
EGD Fast Producer Exchange 1 Destination
8403
EGD Fast Producer Exchange 1 Data Rate
8404
EGD Fast Producer Exchange 1 Data Item 1 (20 items)
8418
Reserved (80 items)
EGD Slow Production (Read/Write Setting) (2 Modules)
8468
EGD Slow Producer Exchange 1 Function
8469
EGD Fast Producer Exchange 1 Destination
846B
EGD Slow Producer Exchange 1 Data Rate
846C
EGD Slow Producer Exchange 1 Data Item 1 (50 items)
846E
Reserved (50 items)
84D0
...Repeated for EGD Exchange 2
Breaker Failure (Read/Write Grouped Setting) (4 or 6 Modules)
8600
Breaker Failure 1 Function
8601
Breaker Failure 1 Mode
8602
Breaker Failure 1 Source
8603
Breaker Failure 1 Amp Supervision
8604
Breaker Failure 1 Use Seal-In
8605
Breaker Failure 1 Three Pole Initiate
8607
Breaker Failure 1 Block
8609
Breaker Failure 1 Phase Amp Supv Pickup
860A
Breaker Failure 1 Neutral Amp Supv Pickup
860B
Breaker Failure 1 Use Timer 1
860C
Breaker Failure 1 Timer 1 Pickup
860D
Breaker Failure 1 Use Timer 2
860E
Breaker Failure 1 Timer 2 Pickup
860F
Breaker Failure 1 Use Timer 3
8610
Breaker Failure 1 Timer 3 Pickup
8611
Breaker Failure 1 Breaker Status 1 Phase A/3P
8613
Breaker Failure 1 Breaker Status 2 Phase A/3P
8615
Breaker Failure 1 Breaker Test On
8617
Breaker Failure 1 Phase Amp Hiset Pickup
8618
Breaker Failure 1 Neutral Amp Hiset Pickup
8619
Breaker Failure 1 Phase Amp Loset Pickup
861A
Breaker Failure 1 Neutral Amp Loset Pickup
861B
Breaker Failure 1 Loset Time
861C
Breaker Failure 1 Trip Dropout Delay
861D
Breaker Failure 1 Target
861E
Breaker Failure 1 Events
861F
Breaker Failure 1 Phase A Initiate
8621
Breaker Failure 1 Phase B Initiate
8623
Breaker Failure 1 Phase C Initiate
8625
Breaker Failure 1 Breaker Status 1 Phase B
GE Multilin
RANGE
0 to 4294967295
0 to 65535
0 to 4294967295
0 to 65535
0 to 65535
0 to 4294967295
0 to 65535
0 to 1
0 to 4294967295
50 to 1000
0 to 65535
---
0 to 1
0 to 4294967295
500 to 1000
0 to 65535
---
0 to 1
0 to 1
0 to 5
0 to 1
0 to 1
0 to 4294967295
0 to 4294967295
0.001 to 30
0.001 to 30
0 to 1
0 to 65.535
0 to 1
0 to 65.535
0 to 1
0 to 65.535
0 to 4294967295
0 to 4294967295
0 to 4294967295
0.001 to 30
0.001 to 30
0.001 to 30
0.001 to 30
0 to 65.535
0 to 65.535
0 to 2
0 to 1
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
M60 Motor Protection System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F003
---
1
F001
---
---
F003
---
1
F001
---
1
F001
---
---
F003
---
1
F001
---
1
F102
---
1
F003
ms
50
F001
---
1
F001
---
---
F001
---
1
F102
---
1
F003
ms
50
F001
---
1
F001
---
---
F001
---
1
F102
---
1
F157
---
1
F167
---
1
F126
---
1
F126
---
1
F300
---
1
F300
pu
0.001
F001
pu
0.001
F001
---
1
F126
s
0.001
F001
---
1
F126
s
0.001
F001
---
1
F126
s
0.001
F001
---
1
F300
---
1
F300
---
1
F300
pu
0.001
F001
pu
0.001
F001
pu
0.001
F001
pu
0.001
F001
s
0.001
F001
s
0.001
F001
---
1
F109
---
1
F102
---
1
F300
---
1
F300
---
1
F300
---
1
F300
DEFAULT
0
0
0
0
B
0
0
0
0 (Disabled)
0
1000
0
0
0 (Disabled)
0
1000
0
0
0 (Disabled)
0 (3-Pole)
0 (SRC 1)
1 (Yes)
1 (Yes)
0
0
1050
1050
1 (Yes)
0
1 (Yes)
0
1 (Yes)
0
0
0
0
1050
1050
1050
1050
0
0
0 (Self-reset)
0 (Disabled)
0
0
0
0
B-45

Advertisement

Table of Contents
loading

Table of Contents