Fujitsu ETERNUS DX100 S4 Basic Operation Manual

Fujitsu ETERNUS DX100 S4 Basic Operation Manual

Hybrid
Hide thumbs Also See for ETERNUS DX100 S4:
Table of Contents

Advertisement

P3AM-7662-09ENZ0
FUJITSU Storage
ETERNUS DX100 S4/DX200 S4,
ETERNUS DX100 S3/DX200 S3
Hybrid Storage Systems
Operation Guide (Basic)

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu ETERNUS DX100 S4

  • Page 1 P3AM-7662-09ENZ0 FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic)
  • Page 2 This page is intentionally left blank.
  • Page 3: About This Manual

    Preface Fujitsu would like to thank you for purchasing the FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 (hereinafter collectively referred to as ETERNUS DX). The ETERNUS DX is designed to be connected to Fujitsu servers (Fujitsu SPARC Servers, PRIMEQUEST, or PRI- MERGY) or non-Fujitsu servers.
  • Page 4: Naming Conventions

    2008 R2 for Itanium-Based Systems ® ® Microsoft Windows Server 2008 HPC Edition ® ® Microsoft Windows Server 2008 R2 HPC Edition FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 5: Symbols Used In This Manual

    FUJITSU Storage ETERNUS DX200 S4, "ETERNUS DX100 S3" refers to the FUJITSU Storage ETERNUS DX100 S3, and "ETERNUS DX200 S3" refers to the FUJITSU Storage ETERNUS DX200 S3. "ETERNUS DX" refers to the ETERNUS DX100 S4, the ETERNUS DX200 S4, the ETERNUS DX100 S3, and the •...
  • Page 6 The black "Must Do..." circle indicates actions that must be taken. The required ac- tion is both illustrated inside the black disk and written above it (e.g. Unplug). FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED...
  • Page 7 - Do not use alcohol or other solvents to clean the ETERNUS storage system. Warning layout ribbon FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 8: Table Of Contents

    2.1.3 Powering On ...............................55 2.1.4 Powering Off ...............................56 2.2 Using the FUNCTION Button ......................58 Chapter 3 Storage System Monitoring FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 9 Chapter 6 Maintenance 6.1 Periodic Backup.......................... 110 6.2 Maintenance Service ........................110 6.2.1 Maintenance Support Period ..........................110 6.2.2 Replacing Batteries............................110 FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 10 6.2.3 Related Service ..............................111 Chapter 7 Troubleshooting 7.1 Check List ........................... 112 7.2 Required Information for Inquiries ..................... 120 FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 11 I/O Module (High-density Drive Enclosure) ....................45 Figure 1.45 Fan Expander Module ..........................46 Figure 1.46 Power Supply Unit (High-density Drive Enclosure) ...................47 FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 12 OFF Position (Marked "¡") of the PSU Switch of a Power Supply Unit ............54 Figure 3.1 ETERNUS Web GUI Screen .........................60 Figure 3.2 Event Notification ............................63 Figure 3.3 Audit Log..............................63 FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 13 Volume Formatting Time (Disk) .......................64 Table 4.2 Rebuild Process Time (Disk) ........................65 Table 4.3 Copyback Process Time (Disk) ........................65 FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 14: Chapter 1 Component Names And Led Names

    An operation panel and drives are installed in the front of the controller enclosure. Controllers and power supply units are installed in the rear. Note that the shape of the controllers is different in the ETERNUS DX100 S4/DX200 S4 and the ETERNUS DX100 S3/DX200 S3.
  • Page 15: Rear

    Controller (CM#0) Cover Remove this when installing an additional controller (optional). Power supply unit (PSU#0) Power supply unit (PSU#1) FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 16: Figure 1.4 Rear View Of A Controller Enclosure (When Two Controllers Are Installed)

    Figure 1.4 Rear View of a Controller Enclosure (When Two Controllers Are Installed) Controller (CM#0) Controller (CM#1) Power supply unit (PSU#0) Power supply unit (PSU#1) FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 17: Components (Front)

    The installation location of the controller enclosure is identified (blinks blue) according to the instruction that is issued from ETERNUS Web GUI or ETERNUS CLI. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 18 *1: When the READY LED and the FAULT LED are both on at the same time, an error has occurred while the Unified configuration is starting up. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED...
  • Page 19: Figure 1.6 2.5" Drives

    Figure 1.9 Drive Slot Numbers (3.5" Type Controller Enclosure) Slot#8 Slot#9 Slot#10 Slot#11 Slot#4 Slot#5 Slot#6 Slot#7 Slot#0 Slot#1 Slot#2 Slot#3 FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 20: Eternus Dx100 S4/Dx200 S4 Components (Rear)

    Two types of host interfaces, which are shown in Figure 1.10, can be installed in the controller. Table 1.3 shows the status and meanings of each LED. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 21: Figure 1.10 Controller (Eternus Dx100 S4/Dx200 S4)

    IDENTIFY/BBU FAULT LED CA#0 FAULT LED DI (OUT) LINK/FAULT LED 10. READY/FAULT LED 11. CA#1 FAULT LED 12. MASTER LED FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 22: Table 1.3 Status And Meanings Of Each Led (Controller)

    There are seven types of host interfaces: FC 16Gbit/s, FC 8Gbit/s, iSCSI 10Gbit/s, iSCSI 1Gbit/s, SAS 12Gbit/s, Ethernet 10Gbit/s, and Ethernet 1Gbit/s. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED...
  • Page 23: Figure 1.11 Fc Interface (Installed In A Controller)

    Host interface port (CA#0, Port#0) Host interface port (CA#0, Port#1) Host interface (CA#1) Host interface port (CA#1, Port#0) Host interface port (CA#1, Port#1) FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 24: Figure 1.13 Host Interface For Fc Cable Connections (Equipped With Sfp+ Modules In All Ports And Installed In The Controllers)

    Host interface port (CA#0, Port#0) Host interface port (CA#0, Port#1) Host interface (CA#1) Host interface port (CA#1, Port#0) Host interface port (CA#1, Port#1) FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 25: Figure 1.15 Iscsi 10Gbit/S (10Gbase-T) Interface, Iscsi 1Gbit/S Interface (Installed In A Controller)

    Host interface port (CA#0, Port#0) Host interface port (CA#0, Port#1) Host interface (CA#1) Host interface port (CA#1, Port#0) Host interface port (CA#1, Port#1) FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 26: Figure 1.17 Ethernet 1Gbit/S Interface (Installed In A Controller)

    Host interface port (CA#1, Port#0) Host interface port (CA#1, Port#1) Host interface port (CA#1, Port#2) 10. Host interface port (CA#1, Port#3) FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 27: Eternus Dx100 S3/Dx200 S3 Components (Rear)

    The controller contains a CPU, cache memory, System Capacitor Unit (SCU), host interfaces, drive interface (DI) ports, and LAN ports. The controller controls all operations in the ETERNUS DX. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED...
  • Page 28: Figure 1.19 Controller (Eternus Dx100 S3/Dx200 S3)

    Install host interfaces. For details, refer to "■ Host Interfaces" (page 29). IDENTIFY/SCU READY LED CA#0 FAULT LED DI (OUT) LINK/FAULT LED 10. READY/FAULT LED FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 29: Table 1.5 Status And Meanings Of Each Led (Controller)

    There are eight types of host interfaces: FC 16Gbit/s, FC 8Gbit/s, iSCSI 10Gbit/s, iSCSI 1Gbit/s, FCoE, SAS 6Gbit/s, Ethernet 10Gbit/s, and Ethernet 1Gbit/s. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED...
  • Page 30: Figure 1.20 Fc Interface (Installed In A Controller)

    Host interface port (CA#0, Port#0) Host interface port (CA#0, Port#1) Host interface (CA#1) Host interface port (CA#1, Port#0) Host interface port (CA#1, Port#1) FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 31: Figure 1.22 Host Interface For Copper Twinax Cable Connection (Installed In A Controller)

    Host interface port (CA#0, Port#0) Host interface port (CA#0, Port#1) Host interface (CA#1) Host interface port (CA#1, Port#0) Host interface port (CA#1, Port#1) FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 32: Figure 1.24 Sas Interface (Installed In A Controller)

    Host interface port (CA#1, Port#0) Host interface port (CA#1, Port#1) Host interface port (CA#1, Port#2) 10. Host interface port (CA#1, Port#3) FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 33: Figure 1.26 Power Supply Unit (Controller Enclosure)

    FAN FAIL The power supply unit or the fan in the power supply unit is in er- (amber) ror status. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 34: 2.5"/3.5" Type Drive Enclosures

    ■ 3.5" Type Figure 1.28 Front View of a 3.5" Type Drive Enclosure Operation panel 3.5" drive Flange cover FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 35: Rear

    Figure 1.30 Rear View of a Drive Enclosure (When Two I/O Modules Are Installed) I/O module (IOM#0) I/O module (IOM#1) Power supply unit (PSU#0) Power supply unit (PSU#1) FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 36: Components (Front)

    FAULT The drive enclosure is in error status. (amber) POWER DC power is supplied to the drive enclosure. (green) FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 37: Figure 1.32 2.5" Drives

    Figure 1.32 2.5" Drives DRIVE READY LED DRIVE FAULT LED Figure 1.33 Drive Slot Numbers (2.5" Type Drive Enclosure) FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 38: Figure 1.34 3.5" Drives

    The LED light up operation was performed from the ETERNUS • CLI command line in order to identify the drive location. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 39: Components (Rear)

    The ports to connect the cables are indicated. This occurs while a (blinks amber) drive enclosure is being added. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 40: Figure 1.37 Power Supply Unit (2.5"/3.5" Type Drive Enclosure)

    FAN FAIL The power supply unit or the fan in the power supply unit is in er- (amber) ror status. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 41: High-Density Drive Enclosure

    This section provides the names of the components in the rear of a high-density drive enclosure. Figure 1.39 Rear View of a High-density Drive Enclosure FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED...
  • Page 42: Components (Front)

    FAULT The drive enclosure is in error status. (amber) POWER DC power is supplied to the drive enclosure. (green) FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 43: Figure 1.41 Disk Activity Panel (Dap)

    The LED light up operation was performed from the ETERNUS • CLI command line in order to identify the drive location. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 44: Components (Internal)

    Figure 1.42 Drives for High-density Drive Enclosures Figure 1.43 Drive Slot Numbers for High-density Drive Enclosures Rear Front FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 45: Components (Rear)

    The ports to connect the cables are indicated. This occurs while a (blinks amber) drive enclosure is being added. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 46: Figure 1.45 Fan Expander Module

    The installation location of the fan expander module is identified (blinks blue) according to the instruction that is issued from ETERNUS Web GUI or ETERNUS CLI. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 47: Figure 1.46 Power Supply Unit (High-Density Drive Enclosure)

    FAN FAIL The power supply unit or the fan in the power supply unit is in er- (amber) ror status. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 48: Power Distribution Units (For Regions Other Than The Emeia, North American, Central American, And Caribbean Regions)

    This is a socket (IEC60320 C14) for incoming power supply. This socket is used to connect a power cord (AC input cable). FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED...
  • Page 49: Power Distribution Units (2U)

    This is a socket (IEC60320 C13) for outgoing power supply. This socket is used to connect a power cord (AC output cable). FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED...
  • Page 50: Chapter 2 Basic Operation

    Figure 2.1 ON Position (Marked "|") of the Main Line Switches on a 1U Power Distribution Unit Main line switch FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED...
  • Page 51: Figure 2.2 On Position (Marked "|") Of The Main Line Switches On A 2U Power Distribution Unit

    Figure 2.3 OFF Position (Marked "¡") of the Main Line Switches on a 1U Power Distribution Unit Main line switch FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED...
  • Page 52: Figure 2.4 Off Position (Marked "¡") Of The Main Line Switches On A 2U Power Distribution Unit

    (marked "¡"), turn it back to ON (marked "|") after the POWER LED of the power supply unit has turned off completely. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED...
  • Page 53: Switching On And Off The Psu Switch On The Power Supply Unit

    • high speed for 30 seconds. Drive enclosure Controller enclosure Power supply unit (PSU#0) Power supply unit (PSU#1) POWER FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 54: Figure 2.6 Off Position (Marked "¡") Of The Psu Switch Of A Power Supply Unit

    Power supply unit (PSU#0) Power supply unit (PSU#1) Check that the POWER LED of the power supply unit is off. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 55: Powering On

    This section explains how to use the Power switch to turn on the ETERNUS DX. For other procedures, refer to the related manuals. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED...
  • Page 56: Powering Off

    The following methods can be used to turn off the power by linking with the server. Via the power synchronized unit • Use the power synchronized unit to turn off the ETERNUS DX. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 57 When a power synchronized unit is connected, the power of the ETERNUS DX is automatically turned on because the power synchronization function is activated. To turn off the ETERNUS DX100 S4/DX200 S4, use the Power switch, a power synchronized unit, ETERNUS •...
  • Page 58: Using The Function Button

    Use the pin to push down the FUNCTION button for three seconds. The ETERNUS DX is in maintenance status when the MAINTENANCE LED is green. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED...
  • Page 59 The MAINTENANCE LED turns off, which indicates that the ETERNUS DX is no longer in maintenance sta- tus. Attach the flange cover. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 60: Chapter 3 Storage System Monitoring

    The status of the ETERNUS DX and the usage status of RAID groups, TPPs, and SDPs can be checked in the Overview screen of ETERNUS Web GUI. Figure 3.1 ETERNUS Web GUI Screen Table 3.1 shows the general status. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 61: Displaying Status Via Eternus Cli

    An abnormality is detected and access from the host cannot be received. Subsystem Down The ETERNUS DX cannot be used. Change Assigned CM CM hot expansion recovery is required. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 62: Event Notification

    Remote Support The information for errors that occur in the ETERNUS DX is notified to the remote support center. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 63: Audit Log

    Process time Setting change ↓ Process details Logout Process result etc. Audit log System administrator Syslog server ETERNUS DX FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 64: Chapter 4 Process Time (Estimated)

    *1: The value shows the time required for volume formatting when the volume capacity is 100GB and there is no server I/O. The time that is required depends on the type and configuration of the disk. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED...
  • Page 65: Rebuild/Copyback Process Time

    *1: The value shows the copyback process time when the volume capacity is 100GB and there is no server I/O. The time that is required depends on the type and configuration of the disk. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED...
  • Page 66 Note that RAID group performance (throughput) may be reduced when a rebuild, copyback, or redundant copy is being performed in the target RAID group. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED...
  • Page 67: Chapter 5 Component Expansion/Function Enhancement

    5.1.1 Installable Drives For installable drives, refer to "Product List". FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 68: Drive Handling Instructions

    Failure to discharge static electricity may cause failure in the ETERNUS DX. Leave the drive in its package until ready to install it. • FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 69: Additional Drive Installation Procedure

    Do Not • Do not install drives that are for use in other devices. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 70 Keep the removed dummy drive units in a safe place where they will not be lost. Install the new drive. Press the catch on the drive lock lever to unlock it. Catch Lock lever FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 71 In the [Drives] screen of [Component] on the ETERNUS Web GUI screen, check that the added drives have been recognized. Set up RAID groups, volumes, hot spares, and host affinity settings, as required. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 72 Insert the drive all the way into the slot, making sure that it is firmly seated and that the lock lever is still left open. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED...
  • Page 73 ETERNUS DX are in normal status. Wear a wrist strap or touch a metal part to discharge the human body's natural static electricity. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED...
  • Page 74 Remove the four M5 screws that are used to fasten the high-density drive enclosure in the rack pillar. (Rack pillar: rear) M5 screws (Rack pillar: front) M5 screws FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 75 Push the two catches on the top board in the direction of the arrows to unlock them. Catch FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 76 Pull the catch on the lock lever of the dummy drive unit to unlock the lock lever, and then open the lock lever upward. Pull up the dummy drive unit in a straight direction. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 77 Insert the drive all the way into the slot, making sure that it is firmly seated and that the lock lever is still left open. Hold the drive with both hands to protect against jarring. • FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 78 In the [Drives] screen of [Component] on the ETERNUS Web GUI screen, check that the added drives have been recognized. Set up RAID groups, volumes, hot spares, and host affinity settings, as required. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 79: Installing Additional Drive Enclosures

    To avoid this, allow the packed drive enclosure sufficient time in the warmer place (one hour for each 15°C of temperature difference) to adapt to the new tempera- ture. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 80 Do not stack the drive enclosures. • Do not knock or drop the drive enclosure on hard objects. • FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 81: Additional Drive Enclosure Installation Procedure

    To disconnect the mini SAS HD cables between enclosures, hold the tab and then pull out the connector. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED...
  • Page 82 Display the [Add Drive Enclosure] screen. In the [Storage] screen of [Component], click [Add Drive Enclosure] in [Action]. The [Add Drive Enclosure] screen appears. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 83 A screen that shows which DE-ID the additional drive enclosure is to be connected to, the type of drive enclosure that is to be added, and the procedure to add the drive enclosure is displayed. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED...
  • Page 84 Rack rail (right) The M5 screw positions for the rack rails are determined by the drive enclosure base line. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 85 Failure to do so may cause injury. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED...
  • Page 86 Upper right rear side of the drive enclosure DE_No. label The DE_No. labels are supplied with the ETERNUS DX. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 87 "Left" is on the exterior [Right] Rack rail (right) "Right" is on the exterior (Rack pillar: front) (Rack pillar: rear) FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 88 (Rack pillar: front) The M4 screw positions for the rack rails are determined by the high-density drive enclo- sure base line. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 89 High-density drive enclosure Front [Left] [Right] 7th hole 7th hole (M5 screw) (M5 screw) High-density drive enclosure base line Rack rail FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 90 Install the high-density drive enclosure in the rack. For safety and stability, use a lifter to install or remove high-density drive enclosures in the rack. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 91 After placing the arm in the bracket, firmly attach the arm with the pin. Cable management arm FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 92 The connectors on the cable with the "l" symbol are connected to the DI (IN) ports on the added • drive enclosure. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 93 Connect the power cord plugs to the power inlets of the power supply units. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED...
  • Page 94 Configuration of IOM#0 in the drive enclosure that is to be added and the power supply units in the system is performed. When the configuration process is complete, the [Disable IOM#1] screen appears. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 95 In the IOM#1 disconnection screen, click the [Next>>] button. The process to disconnect IOM#1 starts. When the disconnection process is complete, the [Detach Cable] screen appears. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 96 Drive enclosure 1 Remove from here Controller 1 Controller enclosure Click the [Next >>] button. The [Connect Cable] screen appears. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 97 Drive enclosure 1 Connect here Controller enclosure Controller 1 Click the [Next >>] button. The [Enable IOM#1] screen appears. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 98 (OUT) port blink on and off. Drive enclosure 2 (drive enclosure Connect that is to be added) here Connect here Drive enclosure 1 FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 99 Step 1 Step Install the drives. For details on drive installation, refer to "5.1.3 Additional Drive Installation Procedure" (page 69). FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 100: Installing Long Wave Sfp+ Modules (16Gbit/S)

    To avoid this, allow the packed SFP+ modules sufficient time in the warmer place (one hour for each 15°C of temperature difference) to adapt to the new tempera- ture. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 101: Long Wave Sfp+ Modules (16Gbit/S) Installation Procedure

    Turn off the ETERNUS DX. Refer to "2.1.4 Powering Off" (page 56) for details on how to turn off the ETERNUS DX. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 102 Connect the FC cable that is disconnected in Step Connect the FC cable connector to the FC port on the Long wave SFP+ module (16Gbit/s). FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 103: Adding Servers

    Enter the name of the RAID group that is to be registered and select "Automatic" or "Manual" for "Create Mode". When "Automatic" is selected, the settings for "Automatic Setting" are displayed. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 104: Volume Creation

    The volume is created and the registration completion screen appears. Click the [Done] button. The screen display returns to the [Volumes] screen. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 105: Connection Setup

    A confirmation screen appears. Click the [OK] button. The host group is added and the registration completion screen appears. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 106 The CA port group is created and the setting completion screen appears. Click the [Done] button. The screen display returns to the [CA Port Group] screen. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 107 The LUN group is added and the setting completion screen appears. Click the [Done] button. The screen display returns to the [LUN Group] screen. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 108 A confirmation screen appears. Click the [OK] button. The host affinity is created and the registration completion screen appears. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 109 Chapter 5 Component Expansion/Function Enhancement Adding Servers Click the [Done] button. The screen display returns to the [Connectivity] screen. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 110: Chapter 6 Maintenance

    6.2.2 Replacing Batteries The batteries of the ETERNUS DX100 S4/DX200 S4 are expendable components that need to be replaced peri- odically. Batteries can be replaced during regular maintenance free of charge. For customers without a maintenance contract, replacement requests (payment required) must be made.
  • Page 111: Related Service

    If a possible error that may occur is detected or an error occurs when remote support service is used, the con- tents of events are automatically sent to the remote support center and notified to the user. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED...
  • Page 112: Check List

    If the Power Resume function is enabled, the ETERNUS DX turns on automatically after the power is re- stored. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 113 SAS HD cable between enclosures. When a mini SAS HD cable between enclosures is not connected FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 114 Protection (Shield) function works and how to check whether it is running, refer to "Design Guide (Basic)". If the problem persists, contact your maintenance engineer. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 115 Note that the settings (network environment settings and firewall settings) for all of the LAN ports are initialized after the following procedure is performed. Remove the flange cover of the controller enclosure. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 116 NUS DX does not respond to SNMP access. Check whether each service can connect to the ETERNUS DX. If it cannot connect, contact your maintenance engineer. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 117 Check the points that are shown below. When the cause is not identified, contact your maintenance engi- neer. Check the battery status of the ETERNUS DX100 S4/DX200 S4 by using ETERNUS Web GUI. If the battery • charge rate is low or if the replacement time for a battery has passed, the performance of the ETERNUS DX degrades because the operational state of the cache is changed to Write Through mode.
  • Page 118 After completing the settings, confirm that access from the server is available. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 119 Set the SAS address, host affinity, and other settings of the new SAS card by referring to the information recorded in Step After completing the settings, confirm that access from the server is available. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED P3AM-7662-09ENZ0...
  • Page 120: Required Information For Inquiries

    ETERNUS Web GUI. For details on obtaining the log/dump information, refer to "Web GUI User's Guide (Settings)". FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2017 FUJITSU LIMITED...
  • Page 121 However, Fujitsu shall assume no responsibility for any operational problems as the result of errors, omissions, or the use of information in this manual. Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information •...

This manual is also suitable for:

Eternus dx200 s4Eternus dx100 s3Eternus dx200 s3

Table of Contents