NEC Univerge SV8100 System Hardware Manual

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
NECIC-AP-001
Issue 2.0

Advertisement

Table of Contents
loading

Summary of Contents for NEC Univerge SV8100

  • Page 1 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn NECIC-AP-001 Issue 2.0...
  • Page 2 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn...
  • Page 3 NEC Infrontia shall not be liable for any errors or omissions. In no event shall NEC Infrontia be liable for any incidental or consequential damages in connection with the use of this manual. This document contains proprietary information that is protected by copyright.
  • Page 4: Table Of Contents

    CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Regulatory Chapter 1; Introduction to SV8100 ................. ECTION ENERAL NFORMATION ..................ECTION QUIPMENT Chapter 2; SV8100 System Specifications ................. ECTION ENERAL NFORMATION ..............ECTION YSTEM LOCK IAGRAM ............. ECTION AXIMUM YSTEM APACITIES 3.1 S...
  • Page 5 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Chapter 3; Installing the SV8100 Chassis ..............3-1 ECTION ENERAL NFORMATION ...............3-1 ECTION NSTALLING HASSIS 2.1 W 19” C ................ 3-2 OUNT THE HASSIS 2.1.1 CHS2U C ........3-3 HASSIS OUNT NSTALLATION 2.2 F...
  • Page 6 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 4.1 CHS2U C ................... 3-55 HASSIS 4.1.1 R ............... 3-55 EMOVE OOLING 4.1.2 I ................. 3-57 NSTALL OOLING Chapter 4; Installing the SV8100 Blades ..............4-1 ECTION ENERAL NFORMATION 1.1 S ..................... 4-1 OCATIONS .................4-3...
  • Page 7 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 3.2.1 D ..................4-24 ESCRIPTION 3.2.2 I ..................4-26 NSTALLATION 3.3 PZ-VM21 (V )............ 4-27 OICE AUGHTER OARD 3.3.1 D ..................4-27 ESCRIPTION 3.3.2 I ..................4-28 NSTALLATION 3.3.3 S ................4-29...
  • Page 8 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 5.1 CD-4COTA (4 L )............4-56 TART NTERFACE 5.1.1 D ..................4-56 ESCRIPTION 5.1.2 I ..................4-58 NSTALLATION 5.1.3 LED I ................4-58 NDICATIONS 5.1.4 C ..................4-59 ONNECTORS 5.2 PZ-4COTE (4 L ) ......
  • Page 9 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 6.1.2 I ..................4-88 NSTALLATION 6.1.3 LED I ................4-89 NDICATIONS 6.1.3.1 A LED - G .............. 4-89 CTIVE REEN 6.1.3.2 B LED - R ..............4-90 6.1.3.3 A LED - R ) ......
  • Page 10 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 7.3 W MDF ..........4-104 IRING ETWEEN THE HASSIS AND THE 7.3.1 C ................4-104 HASSIS ABLES 7.3.2 O ................. 4-108 UTSIDE INES Chapter 5; Installing DT300/DT700 Series (DTL/ITL) Digital and IP Multiline Terminals ..............5-1...
  • Page 11 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 4.5.3 C IP T ONFIGURING THE ELEPHONE FOR THE ORRECT UMBER ..................5-32 4.6 I ...... 5-34 NSTALLING THE IRECTORY ARD ON THE ULTILINE ERMINAL 4.7 R ......5-35 EMOVAL AND...
  • Page 12 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 5.2.7.2 M WM-L UNIT5-73 OUNT ULTILINE ERMINAL ON LATE USING 5.2.8 DSS WM-L UNIT ................5-77 5.2.8.1 M DCL-60-1 C DSS WM-L UNIT 5-77 OUNT ONSOLE ON ALL USING 5.2.8.2 M...
  • Page 13 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 .................... 6-12 ECTION 4.1 I ................6-12 NSTALLING A ...............6-16 ECTION XTERNAL AGING 5.1 E .................... 6-16 XTERNAL 5.2 I ............6-16 NSTALLING AN XTERNAL YSTEM ......6-18 ECTION XTERNAL AGING AND ELAYS 6.1 E...
  • Page 14 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 10.5.1 I PSA-L A ............6-44 NSTALLING THE DAPTER 10.5.2 U PSA-L A .............. 6-51 SING THE DAPTER 11 P ............6-52 ECTION OWER AILURE ELEPHONES 11.1 P ..................6-52 OWER AILURE 11.2 C...
  • Page 15 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100...
  • Page 16 Bluetooth® Cordless Handset Lithium-ion Table R-1 Battery Types and Quantities for Chassis and Blades The UNIVERGE SV8100 CD-CP00 provides memory backup for approximately three years. The Lithium battery should be replaced every two years. IMPORTANT SAFEGUARDS FOR BATTERY DISPOSAL DO NOT PLACE USED BATTERIES IN YOUR REGULAR TRASH! THE PRODUCT YOU PURCHASED CONTAINS LITHIUM, NICKEL-CADMIUM OR SEALED LEAD BATTERIES.
  • Page 17 Contact your local waste management officials for other information regarding the environmentally sound collection, recycling and disposal of the battery contained in this product. The packaging for the UNIVERGE SV8100 system contains the following labels regarding proper disposal. Regulatory...
  • Page 18 Declaration of conformityHereby, “NEC Infrontia”, declares that the SV8100 is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. Electromagnetic Compatibility...
  • Page 19 This product uses Lithium batteries. Do not use any other type. For an overview of the location of batteries used in these systems, the battery replacement or removal instructions please refer to the UNIVERGE SV8100 System Hardware Manual. Regulatory...
  • Page 20: Chapter1; Introduction To Sv8100

    CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Chapter1; Introduction to SV8100 SECTION 1 GENERAL INFORMATION The SV8100 is a full-featured IP based communications system providing a rich feature set of existing system, with pure Voice over IP (VoIP) communications, across corporate Local and Wide Area Networks (LAN and WAN).
  • Page 21 UNIVERGE SV8100 (via TCP/IP) SP310 Softphone Figure 1-1 Simplified SV8100 System Connectivity Highlights of the UNIVERGE SV8100 are as follows:  Pure IP System capable TDM configuration The SV8100 supports both pure IP switching (peer-to-peer connections) and Time Division Switching. The pure IP switching is provided for communications between DT700 series telephones and for CCIS / Remote Unit connections with other SV8100.
  • Page 22 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100  Powerful CPU Blade with Built-in Functionalities The CPU blade of SV8100 is a heart of pure IP connections and TDM-based connections. The CPU blade employs a 32 bit microprocessor. With this processing power and DSP technology, it integrates the following functions on one board.
  • Page 23 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100  Universal Blade Slot (19” Chassis) A 19” Chassis is used for legacy line/trunk blades. One 19” Chassis provides six universal slots and one expansion slot. Also, the universal slots can be used for special application blades without complicated limitation.
  • Page 24: Section 2 Equipment List

    CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 SECTION 2 EQUIPMENT LIST The following tables list all equipment for the SV8100 systems. Table 1-1 Chassis Equipment List Equipment Name Equipment Description Remarks <Attached items> - AC Power Cable - Blank Slot Cover CHS2U 19”...
  • Page 25 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Table 1-4 Blade Equipment List Equipment Abbreviations Equipment Description Remarks Name Main Processor Blade including main CD-CP00 software Bus Unit for System Expansion (for Main PZ-BS10 BUS0 Chassis) Bus Unit for System Expansion (for...
  • Page 26 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Table 1-5 Optional Equipment List Equipment Name Equipment Description Remarks 2 ports External Paging / Doorphone / Audio IP1WW-2PGDAD Adapter Analog Terminal Adapter for Digital Terminal IP1E-1SLTAD Port DP-D-1A Doorphone Box...
  • Page 27 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Table 1-8 IP Multi Terminal (DT700 Series) Equipment List Equipment Name Equipment Description Remarks Value IP 12-button Telephone with Power ITL-2E-1( ) (BK) TEL Failure Adapter ITL-6DE-1( ) (BK) TEL Value IP 6-button Display Telephone...
  • Page 28 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Table 1-9 DT300/DT700 Series Optional Equipment List Equipment Name Equipment Description Remarks Analog Terminal Adapter with Ringer (DT300 APR-L( ) UNIT Only) ADA-L( ) UNIT Recording Jack Adapter ILPA-R( ) UNIT...
  • Page 29 Panel (Wood-SLCD)-L UNIT LCD (320C TEL) Color Side Panel for all terminal (terminal Panel( Logo-Base)-L UNIT base only) <wood color with NEC Logo> Panel (Clear-Base)-L UNIT Color Side Panel for 2E/6DE TEL Color Side Panel for Value Telephone LCD Panel (Clear-VLCD)-L UNIT...
  • Page 30 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Table 1-9 DT300/DT700 Series Optional Equipment List (Continued VAL DIRECTORY CARD Directory Card Holder for Value Telephone UNIT(L) ECO DIRECTORY CARD Directory Card Holder for Economy Telephone UNIT(L) Table 1-10 License List...
  • Page 31 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Table 1-10 License List (Continued) Equipment Name Equipment Description Remarks LKS-UMS-PORT2 LITE-LIC UMS Lite Mail port (2 ports) license LKS-UMS-PORT4 LITE-LIC UMS Lite Mail port (4 ports) license LKS-UMS-PORT8 LITE-LIC UMS Lite Mail port (8 ports) license...
  • Page 32: Chapter2; Sv8100 System Specifications

    CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Chapter2; SV8100 System Specifications SECTION 1 GENERAL INFORMATION This chapter provides detailed specifications for the SV8100 system technician. The technician should review this information carefully before installing the system. SECTION 2 SYSTEM BLOCK DIAGRAM...
  • Page 33 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Table 2-1 List of Abbreviations (Continued) Abbreviation Description Central Office Trunk (Loop and Ground Start Interface) Expansion Loop and Ground Start Interface Blade on COT COTDB Central Processing Unit Direct Inward Dialing...
  • Page 34 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Table 2-1 List of Abbreviations (Continued) Abbreviation Description Property Management System Primary Rate Interface Primary Rate Interface Blade Personal Station PSTN Adapter (analog) Packet Voice Application Router Blade SERIAL Serial Port (on CPU)
  • Page 35 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 2-1 SV8100 System Block Diagram SV8100 System Specifications...
  • Page 36: Section 3 Maximum System Capacities

    CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 SECTION 3 MAXIMUM SYSTEM CAPACITIES The CHS2U is a compact 19” chassis that has six universal slots, one expansion slot and one MPS7101 (power supply unit). When the CD-CP00 is installed in the first CHS2U, it is referred to as the Controlling Chassis.
  • Page 37: System Configulation - Sv8100

    CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 System Configuration – SV8100 The SV8100 19” chassis provides 111 total ports (80 digital terminals) and can be expanded, using three additional 19” chassis, for a maximum of 444 ports (368 digital terminals).
  • Page 38 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Table 2-3 Maximum System Capacities – Chassis shows the maximum number of chassis and related equipment that can be installed in a system. Table 2-3 Maximum System Capacities – Chassis 19”...
  • Page 39 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Table 2-4 SV8100 Maximum System Capacities – Blades 19” 19” 19” Chassis Chassis Chassis Hardware with without Networked Comments Chassis Number of Slot(s) for Interface 5 Slots 6 Slots 23 Slots...
  • Page 40 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Table 2-4 SV8100 Maximum System Capacities – Blades(continued) 19” 19” 19” Chassis Chassis Chassis Hardware with without Networked Comments Chassis Number of Slot(s) for Interface 5 Slots 6 Slots 23 Slots...
  • Page 41 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Table 2-5 Daughter Board Combinations shows each blade and associated daughter board combinations. The daughter boards that can be mounted on specific blades are indicated by a checkmark. For example, the CD-4COTA can have a PZ-4COTE daughter board mounted.
  • Page 42 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 SECTION 4 POWER-BASED CALUCULATOR CHART The UNIVERGE SV8100 system uses two types of power factors. For a single chassis chart refer to Table 2-6 Board Power Factor. For the maximum number of specific blades per package, see Table 2-7 Maximum Number of Package Installed.
  • Page 43 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Table 2-8 Terminal Power Factor Terminal Power Factor Total =< 80 Item Power Factor DTL-24D-1( ) TEL DTL-8LD-1( ) TEL BHA-L UNIT ADA-L UNIT APR-L UNIT APR UNIT BCH-L (BK) UNIT...
  • Page 44 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Table 2-10 IEEE802.af Class Specifications IEEE802.3af Minimum Maximum Class 4 Class 3 6.49W 12.95W Class 2 3.84W 6.49W Class 1 0.44W 3.84W Class 0 0.44W 12.95W System Hardware Manual 2-13...
  • Page 45: Section 5 System Requirement And Specification

    CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 SECTION 5 SYSTEM REQUIREMENT AND SPECIFICATION Cabling This section provides cabling requirements and specifications for various equipment used in the SV8100 system. Figure 2-3 Connecting the DLC Using Twisted 2-Pair Cable...
  • Page 46 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Table 2-11 DT300 Series Loop Resistance and Cable Length By Twisted 1-Pair Cable Terminal or Adapter (without AC Adapter) 24 AWG DTL-2E-1( ) (BK) TEL DTL-6DE-1( ) (BK) TEL DTL-8LD-1( ) (BK)TEL...
  • Page 47 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Table 2-13 Dterm Series i or Dterm IP Terminal Loop Resistance and Cable Length Maximum Maximum By Twisted By Twisted By Twisted By Twisted Loop Loop 1-Pair Cable 2-Pair Cable 1-Pair Cable...
  • Page 48: Power Requirements

    CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Power Requirements A dedicated 100VAC/120VAC/220VAC/230-240VAC 50/60 Hz circuit located within seven feet of the chassis is required. A separate dedicated outlet for each chassis should be installed Double Pole/Neutral Fusing (Power supply fuses are located at both the L and N side) 5.2.1...
  • Page 49: Power Supply Consumption

    CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100  A dedicated outlet, separately fused and grounded for each chassis should be installed. Double Pole/Neutral Fusing (Power supply fuses are located at both the L and N side) 5.2.2 Power Supply Consumption...
  • Page 50: Outside Line Type

     Outside Line Type The following outside lines can be used with the UNIVERGE SV8100 system.  4-wire, E&M Tie Lines (Type I or V, Dial Pulse, or DTMF)  Digital Trunk T1/FT1/E1 (Loop Start, Ground Start, Tie Line (E&M), or DID Signaling) ...
  • Page 51: Transmission, Network And Control Specifications

    Network Time Division Multiplexing (TDM) allows transmission of data and voice simultaneously over one communications medium. The specifications that the UNIVERGE SV8100 system uses for switching, clock, data bus, and timeframe are shown below.  TDM Switching: PCM (A-Law)  TDM Clock: 2.048 MHz ...
  • Page 52: Dialing Specifications

    DTMF signaling includes push button or Touchtone dialing. When a key on a telephone is pushed, two tones (one high frequency and one low frequency) are provided. In the UNIVERGE SV8100 system, the following DTMF specifications are used.  Frequencies: Two sinusoidal frequencies are provided, one from the high frequency group and one from the low frequency group.
  • Page 53: External Equipment Connection

    CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 5.6.3 External Equipment Connection  Door Phone or TV Door Phone  External Speaker via amplifier  External music source for MOH and BGM  Tape recorder for voice recording via IP1WW-2PGDAD ...
  • Page 54: Battery Backup

    CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Battery Backup The UNIVERGE SV8100 system has battery backup functions for system backup and for memory backup. 5.7.1 System Backup (Optional) During a power failure, the system can be backed up using the CHS2U BATT MTG KIT for a backup time of 10 minutes or one of the CHS LARGE BATT SETs for a backup time ranging from 45~180 minutes.
  • Page 55 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Weights and Dimensions Table 2-18 SV8100 Weights and Dimensions shows the shipping weight, height, width and depth of each SV8100 digital multiline terminal, IP multiline terminal, Dterm, Series i multiline terminal, chassis, assorted blades and adapters.
  • Page 56 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Table 2-18 SV8100 Weights and Dimensions (Continued) Shipping Unit Height Width Depth Weight CD-8LCA 6.46 oz 0.98 in 9.45 in 7.68 in (0.183 kg) (25 mm) (240 mm) (195 mm) PZ-8LCE 3.70 oz...
  • Page 57 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Table 2-18 SV8100 Weights and Dimensions (Continued) Shipping Unit Height Width Depth Weight Digital Multiline Terminal DTL-2E-1( ) (BK) TEL 35.27 oz 4.41 in 7.05 in 8.86 in (1.0 kg) (112 mm)
  • Page 58 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Table 2-18 SV8100 Weights and Dimensions (Continued) Shipping Unit Height Width Depth Weight Optional 8LK-L (BK) UNIT 7.05 oz 1.77 in 1.15 in 8.82 in 8LK-L (WH) UNIT (0.2 kg) (45 mm) (29.3 mm)
  • Page 59 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 - - NOTES - - SV8100 System Specifications 2-28...
  • Page 60 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Chapter3; Installing the SV8100 Chassis SECTION 1 GENERAL INFORMATION This chapter contains information to help the technician install the chassis for the SV8100 system. The technician should be familiar with this section before installing any equipment.
  • Page 61 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Universal Slot for Legacy Line/Trunk blades and Application blades (six slots). When used as controlling chassis, the CD-CP00 is mounted in Slot1 (shown) Slot for PZ-BS10/PZ-BS11 blade –Connection with CHS2U chassis...
  • Page 62  Due to chassis weight, NEC recommends only a single CHS2U chassis per wall mount. Figure 3-3 Wall Mount Spacing Guide (19” Chassis) 2. Mark and drill the six holes required for a wall installation.
  • Page 63 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 4. Using six screws, secure the two wall mount brackets to the wall. Refer to Figure 3-4 Install Wall Mount Brackets with Screws for screw location. Figure 3-4 Install Wall Mount Brackets with Screws 5.
  • Page 64 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 3-5 Install Wall Mount Brackets with Screws System Hardware Manual...
  • Page 65 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 6. Align the metal fitting with the upper wall mount bracket. The lower metal fitting rests against the lower wall mount bracket. Secure the metal fitting and upper wall mount bracket with a single screw (see Figure 3-6 Secure Metal Fitting to Upper Wall Mount Bracket with a Screw).
  • Page 66 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 3-7 Secure Metal Fitting to Lower Wall Mount Bracket with Screws 8. Attach the supplied cable support bracket to either end of the lower wall mount bracket with a single screw (refer to...
  • Page 67 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 3-8 Attach Cable Support Bracket with Screw 9. The cable support bracket can be installed any of the four corners of the 19” chassis (refer to Figure 3-9 Attach Cable Support Bracket with Screw).
  • Page 68 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 3-9 Attach Cable Support Bracket with Screw 10. Connect the ground wire to all chassis. Refer to 2.5.5 Install 19” Chassis Grounding on page 3-33 for complete details on grounding the system.
  • Page 69 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Floor Mounting the 19” Chassis The CHS2U controlling and expansion chassis can be mounted on the floor using the CHS BASE UNIT and the CHS2U JOINT BRACKET KIT. 2.2.1 CHS2U Chassis Installation 1.
  • Page 70 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 3-11 Secure CHS BASE UNIT with Anchor Bolts 4. Install the five rubber feet to the bottom of the chassis. Figure 3-12 Install Rubber Feet 5. Position the chassis on top of the CHS BASE UNIT.
  • Page 71 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 3-13 Install CHS2U JOINT BRACKET KIT 7. Connect the ground wire to all chassis. Refer to 2.5.5 Install 19” Chassis Grounding on page 3-33 for complete details on grounding the system.
  • Page 72 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 1. Install the five rubber feet to the bottom of each chassis. Figure 3-14 Install Rubber Feet 2. Using supplied screws in the CHS2U JOINT BRACKET KIT, attach metal brackets to both ends of the 19” chassis and the CHS BASE UNIT.
  • Page 73 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 3. Connect the ground wire to all chassis. Refer to 2.5.5 Install 19” Chassis Grounding on page 3-33 for complete details on grounding the system. 4. Refer to 2.5 Installing the 19” Chassis on page 3-21...
  • Page 74 Figure 3-18 Secure Stand Mount to Floor with Screws on page 3-16). To prevent possible damage to the 19” chassis due to falling, NEC recommends screws be installed in the stand mount brackets as soon as possible. System Hardware Manual 3-15...
  • Page 75 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 3-18 Secure Stand Mount to Floor with Screws 4. Connect the ground wire to all chassis. Refer to 2.5.5 Install 19” Chassis Grounding on page 3-33 for complete details on grounding the system.
  • Page 76 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 1. Install the five rubber feet to the bottom of each chassis. Figure 3-19 Attach Rubber Feet to CHS2U Chassis 2. Each additional chassis will require CHS2U STAND KIT (EXT) to be...
  • Page 77 3-18). To prevent possible damage to the 19” chassis due to falling, NEC recommends screws be installed in the stand mount brackets as soon as possible. 5. Connect the ground wire to all chassis. Refer to 2.5.5 Install 19”...
  • Page 78 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Rack Mounting the 19” Chassis A single or multiple chassis can be rack mounted. Controlling and Expansion chassis can be racked mounted by stacking them horizontally.. 1. The 19” chassis requires two rack mount brackets per chassis for mounting.
  • Page 79 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Repeat for additional chassis mounting. Figure 3-23 Rack Mount Bracket Installed 19”CHS2U 4. Carefully slide the chassis into desired location in the rack. Make sure the hooks on the mounting bracket are inserted into the back of the chassis, securing it in place.
  • Page 80 Inspect the equipment for any physical damage. If you are not sure about the function of a component, review the associated information within this manual. Contact your authorized NEC Sales Representative if you have additional questions. Note that the chassis does not initially contain any blades.
  • Page 81 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 2.5.3 Installing the 19” Controlling Chassis 1. Ensure the chassis is powered down. Do not remove or install this blade with the power on. 2. Align the CD-CP00 blade with the Slot 1 Guides of the Controlling Chassis.
  • Page 82 The EXIFU cable connects the Controlling Chassis and its PZ-BS10 interface to the second, third, and fourth PZ-BS11 interface. Use only the CAT 5 cables provided by NEC to make the connections between the Controlling and Expansion Chassis. The PZ-BS10 provides: ...
  • Page 83 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 2.5.4.1 Connector Pin-Out on the PZ-BS10/PZ-BS11 RJ-61 Cable Connector PZ-BS10 – CN2, CN3, CN4 PZ-BS11 – CN3 Pin No. Connection HW_UP(+) HW_UP(-) HW_DWN(+) FS(+) FS(-) HW_DWN(-) CK8M(+) CK8M(-) Table 3-1 PZ-BS10/PZ-BS11 Connector Pin-Out 2.5.4.2 Install the PZ-BS10 Expansion Base Blade in the CHS2U...
  • Page 84 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 From the left side of the chassis, pull cover outward to expose the expansion bay. Figure 3-29 Open Base Chassis Cover 4. Pull the cover toward you to remove. Cover must be removed prior to installation of PZ-BS10 blade.
  • Page 85 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 3-31 PZ-BS10 Components 6. Slide the PZ-BS10 blade into the chassis until resistance (back plane) is felt. Figure 3-32 PZ-BS10 Blade in Expansion Bay 7. Gently push until the blade seats and install the supplied retaining screw.
  • Page 86 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 8. Align the door tabs with hinges and reattach the cover. Figure 3-33 PZ-BS10 Blade Installed 9. Close the PZ-BS10 cover. Figure 3-34 PZ-BS10 Installed (Cover Closed) 2.5.4.3 Install the PZ-BS11 Expansion Blade in the CHS2U Expansion Chassis .For the Expansion Chassis to function, the PZ-BS10 blade...
  • Page 87 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 2. Locate the door positioned on the left end (expansion bay) of the Expansion Chassis. Figure 3-35 PZ-BS11 Expansion Bay in Expansion Chassis From the left side of the chassis, pull cover outward to expose the expansion bay.
  • Page 88 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 4. Pull the cover toward you to remove.. Cover must be removed to install PZ-BS11 blade. 5. Align the PZ-BS11 blade with the guides located within the expansion bay. Figure 3-37 PZ-BS11 Blade Guides 6.
  • Page 89 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 8. Align the door tabs with hinges and reattach the cover. Figure 3-39 PZ-BS11 Blade Installed 9. Close the PZ-BS11 blade cover. Figure 3-40 PZ-BS11 Blade Installed (Cover Closed) Installing the SV8100 Chassis...
  • Page 90 Figure 3-41 PZ-BS11 Blade Installed (Cover Closed) Ensure Controlling and Expansion chassis are powered down. Using the NEC provided CAT5 straight-through cable(s), attach one end to each Expansion Chassis CN2 connector on the PZ-BS11 blade (see Figure 3-42 System Expansion Cabling on page 3-32.
  • Page 91 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 3-42 System Expansion cabling 3. Repeat for additional Expansion Chassis. Installing the SV8100 Chassis 3-32...
  • Page 92 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 2.5.5 Install 19” Chassis Grounding From the factory, the SG, ETH and PBXG grounds are located inside the chassis and are connected to the FG ground (frame ground) on the back of the chassis.
  • Page 93 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 3-44 19” Chassis Grounding Lug (Multiple-Chassis) 2.5.7 Install AC Power Cords 1. Locate the supplied AC power cord and attach to the AC Inlet located on the back of the Controlling Chassis.
  • Page 94 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 2.5.8 Install AC Power Cords on Multiple-Chassis (Optional) Locate the supplied AC power cords and attach to the AC Inlets located on the back of the Controlling and Expansion Chassis. AC Power Cord to AC Inlets Figure 3-46 Install 19”...
  • Page 95 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 SECTION 3 BATTERY CONNECTION There are two types of battery connection to provide battery life in the event of a power failure, the internal battery and an external battery with CHS LARGE BATT BOX.
  • Page 96 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Remove access panel containing the fan. Refer to Figure 3-48 Removing Access Panel and Figure 3-49 Access Panel Removed. Figure 3-48 Removing Access Panel Figure 3-49 Access Panel Removed System Hardware Manual...
  • Page 97 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Using tie wraps, secure CHS2U BATT CABLE INT in cable guide bracket (refer Figure 3-50 Installing Cable Guide). Figure 3-50 Installing Cable Guide With supplied screw, install cable guide in chassis (refer to...
  • Page 98 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 7. Install two 2.3 AH-12V batteries (locally procured) into the CHS2U BATT MTG KIT (refer to Figure 3-52 Installing Two Batteries). The first battery must be installed on the left side, then slid to the right due to an installation tab on the mounting kit.
  • Page 99 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Connect the provided battery cables to the batteries (refer to Figure 3-53 Installing Battery Cable). Figure 3-53 Installing Battery Cable 10. Connect CHS2U BATT CABLE INT to battery connector (refer to...
  • Page 100 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 11. Install CHS2U BATT MTG KIT into CHS2U chassis and tighten the retaining screws (see Figure 3-55 Installing Battery Tray into CHS2U Chassis). Figure 3-55 Installing Battery Tray into CHS2U Chassis 12.
  • Page 101 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 3.2 Installing the External Batteries An optional (locally procured), external battery source can be used to provide power in the event of a power failure. CHS LARGE BATT BOX (Backup time = Three Hours for 30 Terminals)
  • Page 102 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 3-57 Floor Mount Spacing Guide Mark and drill the four holes required for installing the CHS BASE UNIT. Align bolt holes in CHS BASE UNIT (see Figure 3-57 Floor Mount...
  • Page 103 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 3-58 Installing the CHS LARGE BATT BOX using the CHS2U JOINT BRACKET KIT Secure the CHS LARGE BATT BOX to the CHS BASE UNIT using the CHS2U JOINT BRACKET KIT. Refer to...
  • Page 104 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 3. Remove two screws from front of Battery Tray Suppressor. Refer to Figure 3-60 Removing Battery Tray Suppressor. Figure 3-60 Removing Battery Tray Suppressor Slide Battery Tray Suppressor outward to remove.
  • Page 105 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Remove two screws and remove the Battery Tray Bracket. Refer to Figure 3-62 Removing Battery Tray Bracket. Figure 3-62 Removing Battery Tray Bracket Refer to Figure 3-63 Connecting Battery Cables for connection of battery cable to battery terminals.
  • Page 106 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Install batteries into Battery Tray. Refer to Figure 3-64 Connecting Battery Cables. 14. Using two screws, install the Battery Tray Bracket. Refer to Figure 3-62 Removing Battery Tray Bracket on page 3-46.
  • Page 107 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 3-65 Connecting Battery Cables 16. Insert tabs on cover into holes on CHS LARGE BATT BOX. Slide the cover left until seated and tighten the screw. Refer to Figure 3-66 Installing Cover Battery.
  • Page 108 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 3. Remove fan access panel from rear of CHS2U chassis. Refer to Figure 3-67 Removing Fan Access Panel. Figure 3-67 Removing Fan Access Panel 4. Connect one end of Battery Connection Cable to Battery Connector on rear of Basic and Expansion chassis.
  • Page 109 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 3-69 Single CHS LARGE BATT BOX Connection Figure 3-70 Dual CHS LARGE BATT BOX Connection Installing the SV8100 Chassis 3-50...
  • Page 110 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 6. Insert the access panel tab into the rear of the CHS2U chassis running the Battery Connection Cable through the cutout. Secure panel with the retaining screw. Refer to Figure 3-71 Install the Fan Access Panel.
  • Page 111 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Remove two screws from front of Battery Tray Suppressor. Refer to Figure 3-73 Removing Battery Tray Suppressor. Figure 3-73 Removing Battery Tray Suppressor Slide Battery Tray Suppressor outward to remove. Disconnect the Battery Connection Cables from the Fuse Unit. Refer Figure 3-74 Disconnecting Battery Cables.
  • Page 112 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 3-75 CHS LARGE BATT BOX Fuse Unit 7. Slide the Fuse Unit into the CHS LARGE BATT BOX and tighten the two screws (refer to Figure 3-74 Disconnecting Battery Cables on page 3-52).
  • Page 113 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Insert tabs on cover into holes on CHS LARGE BATT BOX. Slide the cover left until seated and tighten the screw. Refer to Figure 3-77 Installing Cover Battery. Figure 3-77 Installing Cover Battery...
  • Page 114 4.1.1 Remove Cooling Fan To reduce the possibility of electrical shock or damage to equipment, NEC recommends powering off the chassis and disconnecting the AC cable from the power source before removing the chassis cover. Ensure the chassis is powered down.
  • Page 115 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 3. Swing access panel outward and unplug fan power cable. See Figure 3-79 Opening Chassis Access Panel (19” Chassis). Figure 3-79 Opening Chassis Access Panel (19” Chassis) Remove chassis access panel from rear of chassis.
  • Page 116 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 4.1.2 Install Cooling Fan 1. Align replacement fan with holes and secure with two screws (refer to Figure 3-80 Chassis Access Panel Removed on page 3-56). 2. Install cabling into retention clips (refer to...
  • Page 117 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 - - NOTES - - Installing the SV8100 Chassis 3-58...
  • Page 118 Chapter4; Installing the SV8100 Blades SECTION 1 GENERAL INFORMATION This chapter contains information to help the technician install the blades for the UNIVERGE SV8100 system. The technician should be familiar with this section before installing any equipment. Slot Locations Each CHS2U has six slots. In the Controlling Chassis, the CD-CP00 must be...
  • Page 119 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Controlling Chassis CPU Slot Expansion Chassis PZ-BS11 Slot Basic Chassis PZ-BS 10 Slot Figure 4-1 19” Chassis CPU and Expansion Slot Locations Installing the SV8100 Blades...
  • Page 120: Section 2 Installation

    CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 SECTION 2 INSTALLATION Pre-installation planning is essential. Advanced planning minimizes installation time, cost, and disruption of the customer business activities. Installation and Safety Precautions Observe the following precautions when installing the blades to avoid static electricity damage to hardware or exposure to hazardous voltages.
  • Page 121 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Installing an Extension or Trunk Blade 2.2.1 Installing the Blades To install an extension/trunk blade with the system running: 1. Insert the blade within the guide rail and push the blade securely into position.
  • Page 122 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Table 4-1 Extension Blade Installation Order Example Order of Blade Slot Extension Blade Installation Number Numbers CD-16DLCA 200~215 CD-16DLCA 216~231 CD-8DLCA 232~247 PZ-8LCE CD-8DLCA 248~255 After the initial powering up of the system, subsequent powering up or resets do not change the slot identification.
  • Page 123 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 2.2.3 Order of Installing Trunk Blades 2.2.3.1 Installing CD-4COTA, CD-4DIOPB, CD-4ODTB or CD-2BRIA blades The order in which trunk blades are physically inserted determines the numbering plan. To avoid unexpected extension/trunk numbering...
  • Page 124 Controlling and Expansion Chassis in programming for port renumbering or to replace it with a different blade. Deleting a blade may affect blade slot programming capability. Refer to Program 90-05 in the UNIVERGE SV8100 Programming Manual for detailed programming information.
  • Page 125 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Powering Up the SV8100 2.6.1 Performing a Cold Start This section describes the process for starting the system for the first time or starting a system that has been turned off.
  • Page 126 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 2.6.2 Performing a Hot Start The section describes how to load system software from flash memory and customer data from RAM memory. IMPORTANT CONSIDERATIONS System software is loaded from flash memory, and the customer data is loaded from RAM memory.
  • Page 127 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 2.6.3.2 Port Defaults With the default settings, the ports are assigned as follows: Table 4-4 Default Port Settings Port 1~99 : 200~298 Station Ports Port 100~300 : 299~499 Port 301~512 : 5000~5211...
  • Page 128 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 2.6.3.4 Saving Your Configuration When programming is completed, to exit out of the program option and save changes to the CD-CP00: 1. Press EXIT to exit the program options, if needed.
  • Page 129 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 After reloading the customer data to the system, exit programming mode (this could take a minute or more to save the database), then reset the system by powering down and back up. If the system is not reset, not all the uploaded programming changes are in effect.
  • Page 130 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 To perform a system software and firmware upgrade: 1. Turn the system power off. 2. After the system has powers down, insert the USB Memory containing the software upgrade into the USB port on the CD-CP00.
  • Page 131 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 SECTION 3 COMMON CONTROL BLADES The blades described in this section control the common functions of the chassis. CD-CP00 (SV8100 Central Processing Unit) CN3 (for IPLA) Battery Fast Ethernet CN7 BGM/EXSP...
  • Page 132 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 PZ-32IPLA / PZ-64IPLA / PZ-128IPLA PZ-VM21 PZ-ME50 Figure 4-4 CD-CP00 Blade with Daughter Boards Installed 3.1.1 Description The CD-CP00 controls all the functions and operations of the SV8100 system using the system software loaded into the CD-CP00 memory. The system software can be upgraded as new software becomes available.
  • Page 133 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 The CD-CP00 provides: ♦ 200 trunk ports maximum ♦ 512 extension ports maximum - 512 ports IP extensions maximum - 368 digital/analog ports maximum ♦ 256 virtual extensions ♦ Connection for PZ-32IPLA/PZ-64IPLA/PZ-128IPLA Daughter Board ♦...
  • Page 134 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 ♦ Background Music/EXSP Control Port ♦ Status LED ♦ Two Audio Input/Output Terminals ♦ One General Purpose Control Terminal ♦ One Music On Hold External Source ♦ HDLC Packet Processing ♦ Real Time Clock (tolerance 30 seconds/month) ♦...
  • Page 135 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 1. Install the battery on the CD-CP00. The polarity “+” symbol must be on top as illustrated in Figure 4-5 CD-CP00 Battery Installation. Battery Battery Socket Figure 4-5 CD-CP00 Battery Installation 2.
  • Page 136 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 3.1.3 Switch Settings Refer to Table 4-5 CD-CP00 Switch Settings for system restart / system reset and with system power on. Figure 4-3 CD-CP00 Blade Layout on page 4-14 shows the location of the SW1 switch on the CD-CP00 blade.
  • Page 137 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 3.1.4 LED Indications The LEDs on the CD-CP00 indicate the following: ♦ RUN (LED 1) = The CPU is operating (green) ♦ LED 2, and 3 = Alarms (red) ♦ LED 4 = Flash access indication (red) ♦...
  • Page 138 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Table 4-7A CD-CP00 LED Indications (booting)(Continued) LED Indication Status LED2 LED3 LED4 LED5 (LED1) Blinking On Steady When SRAM error USB Memory is Installing Blinking On Steady When Flash memory booting...
  • Page 139 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 3.1.5 Connectors Table 4-8 CD-CP00 Connections describes each connector on the CD-CP00, Table 4-9 CD-CP00 Connector Pin-Outs describes the pin-outs for connectors on the CD-CP00. Refer to Figure 4-3 CD-CP00 Blade...
  • Page 140 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Table 4-9 CD-CP00 Connector Pin-Outs USB Cable Connector – CN5 (Type A, Female) (USB 1.1/2.0 Standard) Pin No. Signal 1 2 3 4 Ethernet Cable Connector – CN7 (RJ-45) (10Base-T/100Base-TX Port) Pin No.
  • Page 141: D Escription

    CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 PZ-ME50 (Memory Expansion Daughter Board) Figure 4-6 PZ-ME50 Daughter Board 3.2.1 Description The Memory Expansion daughter board (PZ-ME50) provides additional memory for the system for use with license control, expanded system networking, and software updates.
  • Page 142 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Table 4-11 PZ-ME50 Capacities provides the memory capacities for the PZ-ME50 blades. Table 4-11 PZ-ME50 Capacities Description Memory Capacity SDRAM 128MB Flash Memory 32MB SRAM Table 4-12 PZ-ME50 Capacities provides the maximum capacities for the PZ-ME50 blade.
  • Page 143: I Nstallation

    CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 3.2.2 Installation To install a PZ-ME50 on the CD-CP00: Do not remove or install the CD-CP00 with the power on. For installation on the CD-CP00 blade refer to Figure 4-4 CD-CP00 Blade with Daughter Boards Installed on page 4-15.
  • Page 144: Pz-Vm21 (V Oice M Ail D Aughter B Oard )

    CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 PZ-VM21 (Voice Mail Daughter Board) Figure 4-7 PZ-VM21 Daughter Board 3.3.1 Description The SV8100 voice mail is a fully integrated, “in-skin” voice mail with Automated Attendant. In addition to the voice mail function, the daughter board provides Voice Response System (VRS) and an optional modem ability for remote maintenance functions.
  • Page 145: I Nstallation

    UNIVERGE SV8100 Depending on the compact flash card used, the voice mail can provide: Table 4-14 Compact Flash Voice Mail Specifications UNIVERGE SV8100 VM8000 InMail Part Name and Capacities AKS VRS OT UNIVERGE SV8100 VM8000 VRS 256M Drive Compact Flash Card with VRS software...
  • Page 146: S Witch S Ettings

    UNIVERGE SV8100 Figure 4-8 Installing the PZ-VM21 One PZ-VM21 daughter board providing InMail can be installed per system. Refer to the UNIVERGE SV8100 System InMail System Guide for complete set-up information. 3.3.3 Switch Settings This daughter board does not have any switch that needs to be set and does not require any hardware setting.
  • Page 147: Pz-32Ipla/Pz-64Ipla/Pz-128Ipla (V Oice Over Ip D Aughter B Oards )

    IP packet signal to a PCM signal format and connects to the PCM time division switch. The PZ-32IPLA/PZ-64IPLA/PZ-128IPLA daughter board is required for IP telephones to communicate with non-VoIP UNIVERGE SV8100 telephones, and place or receive outside calls. The IPLA daughter board provides the voice (RTP/RTCP) processing function.
  • Page 148: I Nstallation

    3-22 for more details. 4. Connect the IPLA daughter board to the CD-RTB, CD-ETIA or to an external switching hub using an Ethernet cable. 5. Refer to the UNIVERGE SV8100 Programming Manual for detailed programming instructions. 3.4.3 Switch Settings These daughter boards do not have any switches that need to be set and do not require any hardware setting.
  • Page 149: Led I Ndications

    CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 3.4.4 LED Indications LED indications for the PZ-32IPLA, PZ-64IPLA and PZ-128IPLA Daughter Boards are indicated in Table 4-16 IPLA LED Indications. Each LED is listed with its associated function and LED and Operational status. Refer...
  • Page 150: C Onnectors

    CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 3.4.5 Connectors Figure 4-10 VoIP Connections shows a typical connection layout. Figure 4-11 Connecting a IPLA daughter board to a Network/PC on Page 4-34 illustrates how to connect a VoIP Daughter Board to a Network or PC.
  • Page 151 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 4-11 Connecting a IPLA daughter board to a Network/PC 4-34 Installing the SV8100 Blades...
  • Page 152: Cd-8Dlca/Cd-16Dlca (D Igital S Tation I Nterface )

    CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 SECTION 4 STATION BLADES CD-8DLCA/CD-16DLCA (Digital Station Interface) Spacers Hole X 4 Daughter Board I/F Interface Circuit # (For PZ-8DLCB) (For PZ-8DLCB) CN101 Digital Extension Interface #1 - #4 CN201 Digital Extension...
  • Page 153: D Escription

    CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Interface Circuit # CN101 Digital Extension Interface #1 - #4 CN201 Digital Extension Interface #5 - #8 CN301 Digital Extension Interface #9 - #12 CN401 Digital Extension Interface #13 - #16...
  • Page 154: I Nstallation

    CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Table 4-18 CD-8DLCA/CD-16DLCA Maximum Upgrade Capacities provides the maximum capacities for the DLCA blades when they are upgraded. Table 4-18 CD-8DLCA/CD-16DLCA Maximum Upgrade Capacities DLCA 19” Chassis 19” Chassis 19” Chassis...
  • Page 155: C Onnectors

    CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Table 4-19 CD-8DLCA/CD-16DLCA LED Indications LED Indication Operation Status Remarks Live LED Busy LED (Green) (Red) System Initializing When you exceed the The assignment of the unit is system capacity. refused...
  • Page 156 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Table 4-20 CD-8DLCA/CD-16DLCA/ RJ-61 Cable Connector Pin-Outs RJ-61 Cable Connector CD-8DLCA – CN101 (ports 1~4), CN201 (ports 5~8) CD-16DLCA – CN101 (ports 1~4), CN201 (ports 5~8), CN301 (ports 9~12), CN401 (ports 13~16) Pin No.
  • Page 157: Pz-8Dlcb (D Igital S Tation D Aughter B Oard )

    CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 PZ-8DLCB (Digital Station Daughter Board) Figure 4-14 PZ-8DLCB Daughter Board 4.2.1 Description The PZ-8DLCB daughter board provides eight digital extensions. This daughter board is installed on the CD-8DLCA and expands the port capacity for the combined blades to 16.
  • Page 158: I Nstallation

    CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 4.2.2 Installation The PZ-8DLCB is installed on the CD-8DLCA. To install: 1. Connect the PZ-8DLCB to the CN2 connector on the CD-8DLCA blade. Refer to Figure 4-12 CD-8DLCA Blade on page 4-34 for the location of the connectors on the blade.
  • Page 159: Cd-4Lca/ Cd-8Lca (4-P Ort /8-P Ort S Ingle L Ine I Nterface )

    CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 CD-4LCA/ CD-8LCA (4-Port/8-Port Single Line Interface) Daughter Board I/F (For PZ-4LCA/PZ-8LCE) CN2 (LCA) SLT Line Interface #1 - #4 BUSY LED (Status for SLT Lines) ON:Extension(s) in Use OFF:Idle LIVE LED...
  • Page 160: D Escription

    CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Daughter Board I/F (For PZ-4LCA/PZ-8LCE) CN2 (LCA) SLT Line Interface #1 - #4 CN3 (LCA) SLT Line Interface #5 - #8 BUSY LED (Status for SLT Lines) ON:Extension(s) in Use OFF:Idle...
  • Page 161: I Nstallation

    CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 The CD-4LCA and CD-8LCA are not rated for OPX use. A CD-4DIOPA blade should be used instead (it supports the analog DID and single line telephone interface functions, such as Off-Premise Extensions).
  • Page 162: Led I Ndications

    CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 4.3.3 LED Indications LED indications for the CD-4LCA/CD-8LCA are listed in Table 4-24 CD-4LCA/CD-8LCA LED Indications. Each LED is listed with its associated function and LED and Operational status. Refer to...
  • Page 163: C Onnectors

    CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 4.3.4 Connectors Table 4-25 CD-4LCA/CD-8LCA RJ-61 Cable Connector Pin-Outs show the pin-outs for the RJ-61 connector. Refer to Figure 4-15 CD-4LCA Blade on page 4-42 Figure 4-16 CD-8LCA Blade on page 4-43 illustrations showing the location of the connectors and the pin number locations on the CD-4LCA/CD-8LCA blades.
  • Page 164: Pz-4Lca/Pz-8Lce (4-P Ort /8-P Ort Slt D Aughter B Oards )

    CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 PZ-4LCA/PZ-8LCE (4-Port/8-Port SLT Daughter Boards) Figure 4-17 Installing the PZ-4LCA Daughter Board System Hardware Manual 4-47...
  • Page 165 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 4-18 Installing the PZ-8LCE Daughter Board 4-48 Installing the SV8100 Blades...
  • Page 166: D Escription

    CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 4.4.1 Description The PZ-4LCA and PZ-8LCE daughter boards are mounted on the CD-4LCA/CD-8LCA. These boards provide: ♦ 4-Port Single Line and 8-Port Single Line analog extension ports (used for on-premise analog telephones, fax machines, and analog modems).
  • Page 167: I Nstallation

    CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 4.4.2 Installation ♦ When connecting a fax machine or analog modem, make sure to set Program 15-03-03 to 1 (special terminal) to avoid communication problems. ♦ The CD-4LCA/CD-8LCA Blade and PZ-4LCA/PZ-8LCE Daughter Board are categorized as TNV2.
  • Page 168: C Onnectors

    CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 4.4.3 Connectors Table 4-27 PZ-4LCA/PZ-8LCE/ RJ-61 Cable Connector Pin-Outs show the pin-outs for the RJ-61 connector. Refer to Figure 4-17 Installing the PZ-4LCA Daughter Board on page 4-46 Figure 4-18 Installing the...
  • Page 169: Cd-Lta (D Term /Slt C Ombination )

    CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 CD-LTA (Dterm/SLT Combination) Daughter Board I/F (For PZ-4COTE/PZ-2BRIA) CN101 (DLCA) Digital Extension Interface #1 - #4 CN102 (DLCA Digital Extension Interface #5 - #8 CN201 (LCA) SLT Line Interface #1 - #2...
  • Page 170: I Nstallation

    CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Table 4-28 CD-LTA Maximum Upgrade Capacities provides the maximum capacities for the CD-LTA blades when they are upgraded. Table 4-28 CD-LTA Maximum Upgrade Capacities CD-CP00 CD-LTA Without PZ-ME50 Only one supported...
  • Page 171: Led I Ndications

    CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 4.5.3 LED Indications LED indications for the CD-LTA are indicated in Table 4-29 CD-LTA LED Indications. Each LED is listed with its associated function and LED and Operational status. Refer to Figure 4-19 CD-LTA Blade on page 4-51 the location of the LEDs on the blade.
  • Page 172: C Onnectors

    CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 4.5.4 Connectors Table 4-30 CD-LTA RJ61 Cable Connector Pin-Outs on page 4-54 shows the pin-outs for the RJ-61 connector. Refer to Figure 4-19 CD-LTA Blade on page 4-51 for an illustration showing the location of the connectors on the CD-LTA blade.
  • Page 173 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 SECTION 5 TRUNK BLADES CD-4COTA (4 Loop Start Interface) Daughter Board I/F (For PZ-4COTE) CN2 (COTA) Analog Trunk From Central Office For Interface Circuit Interface #1 - #4 SLT I/F for...
  • Page 174 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 The CD-4COTA blade consumes four trunk ports ranging between ports 001~200. The CN2 connector provides connection to four analog trunk ports, which are not polarity sensitive (tip-to-tip, ring-to-ring). The power failure circuits (CN3), are not polarity sensitive neither.
  • Page 175 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 5.1.2 Installation Install the CD-4COTA blade into an available slot in the chassis. (Refer to Figure 4-20 CD-4COTA Blade on page 4-55 for a layout of the blade.) If the PZ-4COTE is to be used, install this prior to inserting the CD-4COTA blade into the chassis.
  • Page 176 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 5.1.4 Connectors Table 4-33 CD-4COTA RJ-61 Cable Connector Pin-Outs on page 4-58 shows the pin-outs for the RJ-61 connector. Refer to Figure 4-20 CD-4COTA Blade on page 4-55 for an illustration showing the location of the connectors on the CD-4COTA blades.
  • Page 177 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 PZ-4COTE (4 Loop Start Interface Daughter Board) Daughter Board I/F (CD-4COTA/CD-LTA) CN2 (COTA) Analog Trunk om Central Office For Interface Circuit Interface #1 - #4 CN2 (COTE) Figure 4-21 Installing the PZ-4COTE Daughter Board 5.2.1...
  • Page 178 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 The PZ-4COTE consumes four trunk ports ranging between ports 001~200. The CN2 connector provides connection to four analog trunk ports, which are not polarity sensitive (tip-to-tip, ring-to-ring). The power failure circuits (CN3), are not polarity sensitive neither.
  • Page 179 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 5.2.2 Installation To install the PZ-4COTE: 1. Four spacers are included with the PZ-4COTE. Install the spacers on the CD-4COTA or CD-LTA blade. Make sure to attach the spacers so that they extend out on the side of the daughter board which has the CN1 connector.
  • Page 180 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 CD-2BRIA (2 Basic Rate Interface) Daughter Board I/F (For PZ-2BRIA) CN7 (BRIA) ISDN BRI Circuit #1 CN8 (BRIA) ISDN BRI Circuit #2 BUSY LED (Status for BRI I/F) ON:in Use OFF:Idle...
  • Page 181 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 These trunk circuits can be connected to either ISDN trunks or ISDN telephones, depending on the switch setting within system programming. All ISDN telephone circuits (#1-2 and #3-4 with the BRI daughter board) are supplied DC power from the system.
  • Page 182 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 5.3.3 LED Indications LED indications for the CD-2BRIA are listed in Table 4-37 CD-2BRIA LED Indications. Each LED is listed with its associated function and LED and Operational status. Refer to Figure 4-22 CD-2BRIA Blade on page 4-63 for the location of the LEDs on the blade.
  • Page 183 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 5.3.4 Connectors Table 4-38 CD-2BRIA RJ-61 T-Bus/S-Bus Cable Connector Pin-Outs show the pin-outs for the RJ-61 cable connector for S-Bus and T-Bus connections. Refer to Figure 4-22 CD-2BRIA Blade on page 4-63 for an illustration showing the location of the connectors on the CD-2BRIA blade.
  • Page 184 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 PZ-2BRIA (2 Basic Rate Interface Daughter Board) Daughter Board I/F (For PZ-2BRIA) CN7 (BRIA) ISDN BRI Circuit #1 CN8 (BRIA) ISDN BRI Circuit #2 BUSY LED (Status for BRI I/F) ON:in Use...
  • Page 185 All ISDN telephone circuits [#1-2 (CD-2BRIA blade) and #3-4 (with the PZ-2BRIA daughter board)] are supplied DC power from the UNIVERGE SV8100 systems. System programming must be used to block new calls on the blade. This program will prevent new calls from being established on the blade, but it will not terminate any existing calls.
  • Page 186 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 5.4.2 Installation To install the PZ-2BRIA on the CD-2BRIA: Attach the PZ-2BRIA daughter board to the CD-2BRIA blade by lining up the CN5 connectors and pressing the boards together. (Refer to...
  • Page 187 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 5.4.3 Connectors Table 4-40 PZ-2BRIA RJ-61 T-Bus Cable Connector Pin-Outs show the pin-outs for the RJ-61 cable connector for S-Bus and T-Bus connections. Refer to Figure 4-23 Installing the PZ-2BRIA Daughter Board on page...
  • Page 188 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 CD-4DIOPB (DID/OPX Interface) Figure 4-24 CD-4DIOPB Blade 5.5.1 Description The CD-4DIOPB supports the analog DID and single line telephone interface functions (such as Off-Premise Extension <OPX>). The function type is assigned in programming for each port. The circuit types, however, should be grouped together.
  • Page 189 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Table 4-41 CD-4DIOPB Maximum Upgrade Capacities provides the maximum capacities for the CD-4DIOPB blades when they are upgraded. Table 4-41 CD-4DIOPB Maximum Upgrade Capacities 19” Chassis 19” Chassis Networked 19” Chassis x4...
  • Page 190 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 5.5.4 Connectors The CN2 connector provides connection to four analog DID trunk ports, which are polarity sensitive (tip-to-tip, ring-to-ring). The OPX circuits, however, are not polarity sensitive. The CD-4DIOPB requires one universal slot.
  • Page 191 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 CD-PRTA (PRI/T1/E1 Interface) Figure 4-25 CD-PRTA Blade (Front and Side View) Please view the “SV8100 Digital Trunk Interface Card (E1) Guide” for E-1 Setup, Connector, LED information. 5.6.1 Description The CD-PRTA PRI/T1/E1 blade provides an interface for E1 and ISDN Primary Rate Interface (PRI) applications.
  • Page 192 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Each PRI /T1/E1 blade provides 32 PRI (30 B & 2 D) channels running at 2.048Mbps with 64Kb/s clear channel. This blade supports the following I services: ♦ Basic PRI Call Control (BCC) ♦...
  • Page 193 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 3. Connect the cable from the NT1 Network Termination cable to the CN2 connector on the CD-PRTA. (Refer to Figure 4-26 PRI Layout for NT-1 Network on page 4-75 for a cabling diagram.) ♦...
  • Page 194 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 5.6.3 LED Indications LED indications for the CD-PRTA are listed in Table 4-45 CD-PRTA LED Indications. Each LED is listed with its associated function and LED and Operational status. Table 4-45 CD-PRTA LED Indications...
  • Page 195 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Refer to Figure 4-27 CD-PRTA LED Indication Pattern of Layer 1 on T1 Unit for LED pattern information. 120ms green green green green 1 cycle 3.8sec (120ms x 32 = 3840ms)
  • Page 196 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 5.6.4 Connectors Table 4-47 CD-PRTA RJ-45 Cable Connector Pin-Outs shows the pin-outs for the RJ-45 connector. Refer to Figure 4-25 CD-PRTA Blade (Front and Side View) on page 4-74 for an illustration showing the location of the connectors on the CD-PRIA blade.
  • Page 197 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Table 4-48 CD-PRTA RJ48C Connector Pin-outs shows the pin-outs for the 8-pin RJ48C connector for the network and terminal interfaces. Table 4-48 CD-PRTA RJ48C Connector Pin-outs Network Interface Terminal Interface Pinout for the 8-Pin...
  • Page 198 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 CD-4ODTB (4-Port Tie Line Interface Blade) Figure 4-28 CD-4ODTB Blade 5.7.1 Description The CD-4ODTB Tie Line blade is an out band dial type analog tie line interface blade. This blade supports system connections to either 2wire (four lead, tip/ring) or 4wire (six lead, tip/ring/tip 1/ring 1) E&M signaling tie...
  • Page 199 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Limitation depends on the connecting Router, Multiplexer or Exchange. If the UNIVERGE SV8100 is connected to another UNIVERGE SV8100 directly, there is up to 1,500 ohms loop resistance (including system). Table 4-49 CD-4ODTB Maximum Upgrade Capacities provides the maximum capacities for the CD-4ODTB blades when they are upgraded.
  • Page 200 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 5.7.3 LED Indications LED indications for the CD-4ODTB are listed in Table 4-50 CD-4ODTB Indications. Each LED is listed with its associated function and LED and Operational status. Refer to Figure 4-28 CD-4ODTB Blade on page 4-80 for the location of the LEDs on the blade.
  • Page 201 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 5.7.4 Connectors Table 4-51 CD-4ODTB RJ-61 Cable Connector Pin-Outs on page 4-83 shows the pin-outs for the RJ-61 connector. Refer to Figure 4-28 CD-4ODTB Blade on page 4-80 for an illustration showing the location of the connectors on the CD-4ODTB blade.
  • Page 202 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 5.7.5 Connections Figure 4-29 Voice Signal Connection for Type I And V on page 4-84 Figure 4-30 Control Signal Connection on page 4-85 show the signaling methods for circuit types. Figure 4-29 Voice Signal Connection for Type I And V...
  • Page 203 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 4-30 Control Signal Connection 4-86 Installing the SV8100 Blades...
  • Page 204 Battery Active LED Figure 4-31 CD-VM00 Blade 6.1.1 Description This blade is a PC platform installed in the UNIVERGE SV8100 that contains data storage for voice recording and application software supporting a maximum of 16 ports. System Hardware Manual 4-87...
  • Page 205 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 A digital signal processor/voice processing section handles the following functions: ♦ DTMF detection ♦ DTMF generation ♦ General tone detection ♦ FAX CNG tone detection ♦ PCM compression for audio recording/playback ♦...
  • Page 206 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 4. Push the other end down until the locks on both sides lock into place (refer to Figure 4-33 Install the SO-DIMM Memory). Figure 4-33 Install the SO-DIMM Memory 5. Install the Compact Flash drive into slot CN7, make sure the drive is...
  • Page 207 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 6.1.3.2 Busy LED – Red The Busy LED is controlled by the DSP and indicates the port status. ♦ Off: Power off or idle. ♦ On: Reset. 6.1.3.3 Application LED – Red/Green (Dual Color) The Application LED is controlled by the DSP indicates the state of the software running on the APSU.
  • Page 208 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 6.1.4.2 DB9 to 6-pin Modular RS-232 Adapter Figure 4-35 CD-VM00 DB9 to 6-Pin Modular RS-232 Adapter 6.1.4.3 RS-232 Serial Cable (DTE) Figure 4-36 CD-VM00 RS-232 Serial Cable (DTE) System Hardware Manual...
  • Page 209 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 6.1.4.4 RS-232 Serial Cable (DCE) Figure 4-37 CD-VM00 RS-232 Serial Cable (DCE) 6.1.4.5 USB Interface The APSU provides two USB interfaces that can be used for the following devices: ♦ USB Keyboard ♦...
  • Page 210 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 The RJ-45 connector pin-out is shown in Table 4-52 Ethernet Connector Pin-Out on page 4-92. Table 4-52 Ethernet Connector Pin-Out View Pin No. Signal Note (PIN1 --- PIN8) 10BASE-T / 100BASE-TX port...
  • Page 211 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 CD-PVAA (Conference Bridge) Compact Flash Conference/IVR Red: Reading Ethernet (RJ45) Green: Data Yellow: Connectivity Reset Switch BUSY LED LIVE LED ON: In Use (Status LED) OFF: Idle Figure 4-38 CD-PVAA Blade 6.2.1...
  • Page 212 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 6.2.2 Installation To install the CD-PVAA: ♦ Install CompactFlash into CD-PVAA ♦ Plug the into any universal slot on the chassis ♦ Refer to Program 10-55-01 to configure the IP Address of the CD-PVAA ♦...
  • Page 213 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 6.2.4 LED Indications Active LED – Green The Active LED is controlled by the DSP and indicates the board operational status. ♦ Off: Power off ♦ On: Reset ♦ Slow Flash: Board is running but not in sync with the chassis ♦...
  • Page 214 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 CD-RTB (4-Port Router) Back Plane LIVE LED (Status LED) Reset Switch Figure 4-39 CD-RTB Blade 6.3.1 Description The Router blade is a 4-port switching hub which complies with the ethernet specification for both 100Base-TX and 10Base-T. This blade is compatible in LAN applications using 10Mbps and 100Mbps.
  • Page 215 ♦ Maximum 100m Transmission Distance by CAT-5 Cable ♦ 2 Status LEDs The VoIPDB, required for IP telephones to communicate with non-VoIP UNIVERGE SV8100 telephones, and to place or receive outside calls, must be connected to either an external switching hub or to the Router blade.
  • Page 216 UNIVERGE SV8100 6.3.2 Installation To install the CD-RTB: 1. Plug the CD-RTB blade in any universal slot. 2. Refer to the UNIVERGE SV8100 Programming Manual for required programming. 6.3.3 LED Indications LED indications for the CD-RTB are indicated in Table 4-54 CD-RTB LED Indications.
  • Page 217 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 CD-ETIA (Gigabit PoE Switch) RJ45 Connector (x8) Activity LED (x8) Figure 4-40 CD-ETIA Blade 6.4.1 Description The CD-ETIA blade is a managed 8-port gigabit ethernet PoE switch. Ports 1 and 8 are the default uplink ports. All the user management and stacking are based on this setup.
  • Page 218 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Table 4-55 CD-ETIA Maximum Upgrade Capacities provides the maximum capacities for the CD-ETIA blades when they are upgraded. Table 4-55 CD-ETIA Maximum Upgrade Capacities 19” Chassis 19” Chassis Networked 19” Chassis x4...
  • Page 219 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 6.4.2.3 Group Formation When a CD-ETIA determines that it is an Add-on blade due to the lack of an IP address from the backplane, it sends a broadcast P2P message (defined in separate documentation) to all the CD-ETIA blades in the system until it receives an acknowledge message from the Main blade.
  • Page 220 The grouping of the three CD-ETIA blades to form a 20 port switch is restricted to reside in a single system location. The grouping is not allowed where the CD-ETIA blades are placed as part of the NetLink feature in the UNIVERGE SV8100 system. 6.4.2.5 Unmanaged Switch Functions...
  • Page 221 Wiring Between the Chassis and the MDF 7.3.1 Chassis Cables The chassis is equipped with two MDF Cable Assemblies. NEC recommends that the MDF Cable Assembly be used to connect th multiline terminals, single line telephones (except PFT), PVAA and DID/OPX lines.
  • Page 222 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Table 4-56 MDF Cable Colors Table 4-57 MDF Cable Connections (Station) System Hardware Manual 4-105...
  • Page 223 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Table 4-57 MDF Cable Connections (Station) (Continued) 4-106 Installing the SV8100 Blades...
  • Page 224 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Table 4-58 MDF Cable Connections (Trunk) COTA DIOPB System Hardware Manual 4-107...
  • Page 225 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Table 4-58 MDF Cable Connections (Trunk) (Continued) COTA DIOPB 7.3.2 Outside Lines An RJ-61 connector is authorized by the FCC for connection of CO lines is an RJ-61. The lines are connected in sequence in this termination block.
  • Page 226 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Chapter5; Installing DT300/DT700 Series (DTL/ITL) Digital and IP Multiline Terminals SECTION 1 GENERAL DESCRIPTION This chapter provides information about the DT300/DT700 Series digital and IP terminals in addition to the single line telephones and cordless telephones.
  • Page 227 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Table 5-1 Terminal Category Reference Chart (Continued) DT300/DT700 Series Terminals Category Equipment Product Name (idea) Note 2-button without LCD ITL-2E-1( ) (BK) TEL Economy Terminal 6-button with LCD ITL-6DE-1( ) (BK) TEL...
  • Page 228 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Table 5-2 Terminal and Adapter Compatibility (Continued) Adapter Unit Terminal ADA-L APR-L ILPA PSA-L BCH-L BHA-L IP Terminals: - -  - - - ITL-2E-1( ) (BK) TEL - - ...
  • Page 229 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Table 5-3 Terminal and Line Key/LCD Compatibility (Continued) Line Key / LCD Terminal 8LK-L 8LKD(LD)-L 8LKI(LD)-L 12LK-L LCD(BL)-L DCL-60 IP Terminals: - - - - - - ITL-2E-1( ) (BK) TEL -...
  • Page 230 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Table 5-4 Terminal and Ten Key Kit Compatibility (Continued) Ten Key Kit Terminal BS(F)-L BS(S)-L BS(ACD)-L BS(Braille)-L BS(Retro)-L (V-Hotel) (S-Hotel) IP Terminals:  - - - - - - ITL-2E-1( ) (BK) TEL ...
  • Page 231 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Table 5-5 Terminal and Optional Equipment Compatibility (Continued) Equipment Terminal PSA-L WM-L* PANEL-L IP Terminals: -   ITL-2E-1( ) (BK) TEL -   ITL-6DE-1( ) (BK) TEL  ...
  • Page 232 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 SECTION 2 DT300 SERIES DIGITAL MULTILINE TERMINALS The DT300 Series offers a new exciting line up of digital telephones. These telephones (except economy), have a modular design that allows the telephone to be upgraded and customized.
  • Page 233 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 2.1.2 DTL-6DE-1( ) (BK) TEL This digital economy multiline terminal has 6 line keys with display and is available in black only. The terminal features:  Non-modular design  Four-step adjustable base ...
  • Page 234 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100  Backlit Numbered Keypad for easy viewing  Full-duplex handsfree operation Figure 5-3 DTL-8LD-1( ) TEL 2.1.4 DTL-12BT-1( ) (BK) TEL This digital value multiline terminal has 12 line keys and is available in black only.
  • Page 235 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 5-4 DTL-12BT-1( ) TEL 2.1.5 DTL-12D-1( ) (BK) TEL/DTL-12D-1( ) (WH) TEL This digital value multiline terminal has 12 line keys and is available in both black and white. The terminal features: ...
  • Page 236 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 5-5 DTL-12D-1( ) TEL 2.1.6 DTL-12PA-1( ) (BK) TEL This digital value multiline terminal with Analog Power Failure adapter has 12 line keys and is available in black only. The terminal features: ...
  • Page 237 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 5-6 DTL-12PA-1( ) TEL 2.1.7 DTL-24D-1( ) (BK) TEL/DTL-24D-1( ) (WH) TEL This digital value multiline terminal has 24 line keys and is available in both black and white. The terminal features: ...
  • Page 238 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 5-7 DTL-24D-1( ) TEL 2.1.8 DTL-32D-1( ) (BK) TEL/DTL-32D-1( ) (WH) TEL This digital value multiline terminal has 32 line keys (24 line keys plus 8 line keys LK Unit) and is available in both black and white.
  • Page 239 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 5-8 DTL-32D-1( ) TEL Installing DT300/DT700 Series (DTL/ITL) Digital and IP Multiline Terminals 5-14...
  • Page 240 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 SECTION 3 DT700 SERIES IP MULTILINE TERMINALS The DT700 Series offers a new exciting line up of IP telephones. These telephones (except economy), have a modular design that allows the telephones to be upgraded and customized.
  • Page 241 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 3.1.2 ITL-6DE-1( ) (BK) TEL This IP economy multiline terminal has six line keys with display and is available in black only. The terminal features:  Non-modular design  Four-step adjustable base ...
  • Page 242 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100  Two 224 X 96 full dot gray scale LCDs with cursor keys  Backlit Numbered Keypad for easy viewing  Full-duplex handsfree operation  Wideband handset  IEEE 802.3af compliant ...
  • Page 243 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100  XML open interface  10Base-T/100Base-TX network interface  Backlit LCD Figure 5-12 ITL-12D-1( ) TEL 3.1.5 ITL-12PA-1( ) (BK) TEL This IP value multiline terminal with Analog Power Failure adapter has 12 line keys and is available in black only.
  • Page 244 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100  Backlit LCD  PSA Adapter for Power Failure Figure 5-13 ITL-12PA-1( ) TEL 3.1.6 ITL-24D-1( ) (BK) TEL/ITL-24D-1( ) (WH) TEL This IP value multiline terminal has 24 line keys and is available in both black and white.
  • Page 245 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 5-14 ITL-24D-1( ) TEL 3.1.7 ITL-32D-1( ) (BK) TEL/ITL-32D-1( ) (WH) TEL This IP value multiline terminal has 32 line keys (24 line keys plus an 8 line keys LK Unit) and is available in both black and white. The terminal features: ...
  • Page 246 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 5-15 ITL-32D-1( ) TEL 3.1.8 ITL-320C-1( ) (BK) TEL This IP multiline terminal features a large color touch panel LCD and is available in black only. The terminal features: ...
  • Page 247 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 5-16 ITL-320C-1( ) TEL Installing DT300/DT700 Series (DTL/ITL) Digital and IP Multiline Terminals 5-22...
  • Page 248 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 SECTION 4 INSTALL MULTILINE TERMINALS 4.1 Connecting the DT300 Series Multiline Terminal to the System This instruction applies to all DT300 Series multiline terminals. 1. Plug the telephone cord into the modular jack on the bottom side of the multiline terminal.
  • Page 249 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 2. Lead the Line and Handset cables through the applicable grooves. Figure 5-18 Leading Line Cords on a multiline terminal 4.2 Applying Power to the DT700 Multiline Terminals The DT700 terminals support two different methods to power the terminal: ...
  • Page 250 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 4.3 Connecting the IP Multiline Terminal to the Network and PC These instructions for connecting an IP multiline terminal to the Network and PC apply to DT700 multiline terminals. Refer to Figure 5-19 IP Terminal Connector Locations.
  • Page 251 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 AC/DC Adapter Figure 5-20 Typical Network IP Connection 4.4 Adjusting the LCD on the Multiline Terminal DT300/DT700 Series display multiline terminals have an adjustable Liquid Crystal Display (LCD). The LCD can be adjusted by pulling up or pushing down as desired.
  • Page 252 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 4.5 Installing Line Key Kit (12LK-L KIT) The 12LK-L KIT provides twelve additional buttons to ITL or DTL multiline terminals. The 12LK-L KIT kit:  Mounts directly to top side of terminal ...
  • Page 253 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Line Key Panel Figure 5-23 Removing the Line Key Panel 4. Lift and remove the DESI sheet. Figure 5-24 Removing the DESI Sheet 5. Press the right end of the Line Key placeholder and lift to remove...
  • Page 254 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 5-25 Removing the Line Key Placeholder 6. Install the 12LK-L KIT and slide until aligned with the Tab Hole. Figure 5-26 Aligning the 12LK-L KIT System Hardware Manual 5-29...
  • Page 255 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 7. Press on the right end of the 12LK-L KIT until a clck is herad Figure 5-27 Installing the 12LK-L KIT 8. If desired, print and install the new DESI sheet.
  • Page 256 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 9. Install the supplied Line Key Panel (refer to Figure 5-28 Installing the Line Key Panel). Line Key Panel Figure 5-29 Installing the Line Key Panel 10. Install the side panel.
  • Page 257 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 4.5.2 Configuring the Digital Telephone for the Correct Number of Line Keys With the telephone not plugged in and the handset on-hook, press the 4 and 6 buttons on the numbered keypad and connect the telephone cable.
  • Page 258 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Press 2 for Key Kit Type. Press the UP/Down key to select the keypad kit.. Table 5-7 Ten-Key Kit Type Ten-Key Kit Entry Description Kit1 Type A Japan with cursor key Kit2 Type A .US with cursor key...
  • Page 259 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 4.6 Installing the Directory Card on the Multiline Terminal A directory card can be attached to DT300/DT700 Series multiline terminals. The directory card can be used to record often dialed numbers or other important information.
  • Page 260 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 5-31 Attaching Directory Card Holder to the multiline terminal 4.7 Removal and Replacement of the Numbered Keypad  Standard Numbered Keypad The Numbered Keypad (in black or white), is commonly delivered in the...
  • Page 261 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 4.7.1 Removing the Numbered Keypad To prevent possible damage to the Numbered Keypad or the DTL/ITL multiline terminal during installation or removal, disconnect the line cord/ LAN cable and the AC/DC adapter from the DTL/ ITL multiline terminal.
  • Page 262 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 4.7.2 Installing the Numbered Keypad Slide the replacement numbered keypad into the grooves located on the inside of the telephone, then press down on the keypad to snap it into place. See...
  • Page 263 Removal and Replacement of the BS( )-L Kit (Ten Key Kit) The Business BS( )-L Kit (in black or white), is commonly delivered with the UNIVERGE SV8100 multiline terminal. If required, the BS( )-L Kit can be removed and replaced on the DT300/DT700 Series multiline terminal.
  • Page 264 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Carefully pry and lift the Ten Key kit from the multiline terminal. Figure 5-38 Remove the Ten Key Kit 4.8.2 Install the BS( )-L Kit 1. Slide replacement Ten Key kit into position. Tabs of kit will fit into holes on the multiline terminal.
  • Page 265 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 2. Press down until the Ten Key kit clicks into place. Figure 5-40 Secure the Ten Key Kit 3. Reinstall the Line Key and Numbered Keypad panels on the multiline terminal.
  • Page 266 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 4.8.3 Configuring the Digital Telephone for the Ten Key Kit With the telephone not plugged in and the handset on-hook, press the 4 and 6 butt ons on the numbered keypad and connect the telephone cable.
  • Page 267 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 At the Login screen, enter the user name (default = ADMIN) and password (default = 6633222) and press the OK Soft Key. Press 3 for Maintenance Setting. Press 4 for Adjust.
  • Page 268 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Table 5-11 Line Key Kit Type (Continued) Line Key Kit Entry Description Kit6 Value 6-Button Kit2 Value 2-Button Kit0 IP-CTS Press Soft Key 4 for OK to complete. Continue pressing Soft Key 4 to exit (Exit-Exit-Save). The terminal will reset automatically.
  • Page 269 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 4.10 Removing or Installing the Tilt Legs on the Multiline Terminal The Tilt Legs can be removed or installed on the DT300/DT700 Series multiline terminal. 4.10.1 Remove Tilt Legs Place the telephone on a flat surface (button side down).
  • Page 270 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 4.10.2 Install Tilt Legs Place the telephone on a flat surface (button side down). Lay the adjustable Tilt legs on top of the telephone. See Figure 5-45 Attach Tilt Legs to DT300/DT700 Series Terminal.
  • Page 271 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 5-46 Connecting the Tilt Legs Snap legs together and adjust to desired height. Refer to Figure 5-47 Adjust Height of DT300/DT700 Series Terminal). Figure 5-47 Adjust Height of DT300/DT700 Series Terminal...
  • Page 272 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 4.11 Wall Mounting the Multiline Terminal You can wall mount a DT300/DT700 Series connection multiline terminal using the base cover or an optional wall mount unit. A wall mount unit must be used if adapters are installed on the multiline terminal.
  • Page 273 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 4.11.1.2 Wall Mounting the multiline terminal Plug line cord in the wall receptacle. Leave about eight inches of cord and bundle the rest as shown in Figure 5-50 Bundling the Line Cord.
  • Page 274 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 5-52 Mount multiline terminal Wall on Wall Plate Push spare line cord behind the multiline terminal. 4.11.1.3 Removing the multiline terminal from the Wall Mounted Base Plate. To remove the multiline terminal, push up on the telephone until it comes loose.
  • Page 275 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 4.11.1.4 Wall Mounting the Base on a Switch Box Locate the screw holes on the base and hang the cover over the screws on the switch box as illustrated in Figure 5-49 Wall Mounting Base on Switch Box.
  • Page 276 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 SECTION 5 MULTILINE TERMINALS OPTIONAL EQUIPMENT 5.1 DT300/DT700 Series Terminal Options The following chart provides a quick overview of the options available with the DT300/DT700 Series telephones. Table 5-12 Connectivity of Options...
  • Page 277 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 DT300/DT700 Series Optional Terminal Equipment 5.2.1 8LK-L (BK) UNIT/8LK-L (WH) UNIT Provides eight additional line keys to ITL or DTL terminals (except Economy). The unit features:  Mounts directly to right side of terminal ...
  • Page 278 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 3. Pry the side panel from the multiline terminal. Figure 5-57 Remove Side Panel from multiline terminal 4. Return the multiline terminal to the buttons side up position. 5. Fit the projections on the side of the 8LK-L UNIT into the guide holes on the side of the multiline terminal.
  • Page 279 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 8. Open the small door covering the side option connectors by pulling the cover handle to the front. Figure 5-59 Install the 8LK-L UNIT Cable 9. Connect the cable from the 8LK-L UNIT to the side...
  • Page 280 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 5-60 8LKD (LD)-L UNIT 5.2.2.1 Installing the 8LKD (LD)-L UNIT To prevent possible damage to the 8LKD (LD)-L UNIT or the DTL multiline terminal during installation or removal, disconnect the line cord/LAN cable and the AC/DC adapter from the DTL multiline terminal.
  • Page 281 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 3. Remove the screw (refer to Figure 5-61 Remove Side Panel from multiline terminal on page 5-55). 4. Carefully, return the multiline terminal to the buttons side up position. 5. Remove the soft keys and line key kit from the telephone.
  • Page 282 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 5-63 Ribbon Cable Installed 9. Align the projections on the bottom of the 8LKD (LD)-L UNIT with the guide holes on top of the multiline terminal. 10. Slide the 8LKD (LD)-L UNIT toward the keypad buttons...
  • Page 283 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 11. Holding the LCD in place, turn the multiline terminal button side down. 12. Install the screw (refer to Figure 5-65 Install Screw). Figure 5-65 Install Screw 13. Attach the side panel to the side of the 8LKD (LD)-L...
  • Page 284 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 5-66 8LKI (LD)-L UNIT 5.2.3.1 Installing the 8LKI (LD)-L UNIT To prevent possible damage to the 8LKI (LD)-L UNIT or the ITL multiline terminal during installation or removal, disconnect the line cord/LAN cable and the AC/DC adapter from the ITL multiline terminal.
  • Page 285 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 3. Remove the screw (refer to Figure 5-67 Remove Side Panel from multiline terminal on page 5-59). 4. Carefully, return the multiline terminal to the buttons side up position. 5. Remove the soft keys and line key kit from the telephone.
  • Page 286 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 5-69 Ribbon Cable Installed 9. Align the projections on the bottom of the 8LKI (LD)-L UNIT into the guide holes on top of the multiline terminal (refer to Figure 5-69 Ribbon Cable Installed).
  • Page 287 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 11. Holding the LCD in place, turn the multiline terminal button side down. 12. Install screw (refer to Figure 5-71 Install Screw). Figure 5-71 Install Screw 13. Attach the side panel to the side of the 8LKI (LD)-L UNIT...
  • Page 288 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Keep the following in mind when installing DSS Consoles:  A 60-Button DSS Console requires a separate digital station port when pairing with a digital multiline terminal. For IP terminals, the console is connected to the side option slot using a special cable.
  • Page 289 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Pry the side panel from the multiline terminal. Figure 5-73 Remove Side Panel from multiline terminal Turn the multiline terminal button side up. Fit the projections of the supplied bracket into the side of the multiline terminal.
  • Page 290 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Carefully push the Serial cable into the Serial Cable Groove (ITL, DT700 only). Figure 5-75 Press Serial Cable into Groove Using the guides, slide the DCL-60-1( ) onto the installed bracket (refer to Figure...
  • Page 291 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 10. Open the small door covering the side option connectors by pulling the cover latch toward you (refer to Figure 5-72 Serial Cable Installed, ITL, DT700 only). 11. Connect the cable from the DCL-60-1( ) CONSOLE to the Side Option Connector on the multiline terminal and close the cover (ITL, DT700 only).
  • Page 292 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 5-78 Connect AC Adapter Cable 18. Complete the installation by reattaching both plastic panels to the front of the multiline terminal. Figure 5-79 DCL-60-1( ) CONSOLE Installed 5.2.5 LCD (BL)-L (BK) UNIT/LCD (BL)-L (WH) UNIT...
  • Page 293 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 5-80 LCD (BL)-L UNIT 5.2.6 PANEL ( )-L UNIT Optional plastic color side panels that allow users to customize the ITL/DTL terminals. The following colors are available for the Base...
  • Page 294 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 5.2.7 WM-L UNIT The WM-L UNIT (Wall Mount Unit) is used to attach any DT300/DT700 Series multiline terminal to the wall. This unit connects to the bottom of the telephone. When optional adapters are used, the multiline terminal must be installed on the wall using the WM-L UNIT .
  • Page 295 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 5-83 Attach WM-L UNIT Using Screws Plug one end of the line cord into the wall receptacle. Leave about eight inches of cord and bundle the rest. Plug the opposite end of the line cord into the multiline...
  • Page 296 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Align the four cutouts on the bottom of the multiline terminal (refer to Figure 5-85 Cutouts for WM-L UNIT) with the tabs on the WM-L UNIT (refer to Figure 5-86 WM-L UNIT Tabs).
  • Page 297 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Push down until the multiline terminal snaps into place (refer to Figure 5-87 WM-L UNIT Installed). Figure 5-87 WM-L UNIT Installed To release the multiline terminal from the WM-L UNIT, press the release button and push the telephone up...
  • Page 298 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 5.2.7.2 Mount Multiline Terminal on Wall Plate using WM-L UNIT Locate the screw holes on the base and hang the cover over the screws on the wall plate as illustrated Figure 5-89 Attach WM-L UNIT to Wall Plate.
  • Page 299 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Align the four cutouts on the bottom of the multiline terminal (refer to Figure 5-91 Cutouts for WM-L UNIT) with the tabs on the WM-L UNIT (refer to Figure 5-92 WM-L UNIT Tabs).
  • Page 300 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Push down until the multiline terminal snaps into place (refer to Figure 5-93 WM-L UNIT Installed). Figure 5-93 WM-L UNIT Installed To remove the WM-L UNIT from the wall panel, push up...
  • Page 301 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 To separate the multiline terminal from the WM-L UNIT, press the release button and slide the multiline terminal up (refer to Figure 5-95 WM-L UNIT Release Button). Figure 5-95 WM-L UNIT Release Button...
  • Page 302 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 5.2.8 DSS WM-L UNIT The DSS WM-L UNIT (Wall Mount Unit) is used to attach the DCL-60-1 CONSOLE to the wall. This unit connects to the bottom of the terminal. 5.2.8.1 Mount DCL-60-1 CONSOLE on Wall using DSS WM-L...
  • Page 303 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Attach the DSS WM-L UNIT to the wall using six screws or, using two wall mounted screws (refer to Figure 5-97 Attach DSS WM-L UNIT Using Screws). Figure 5-97 Attach DSS WM-L UNIT Using Screws 5.2.8.2 Mount DCL-60-1 CONSOLE on Wall Plate using DSS...
  • Page 304 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Plug one end of the line cord into the wall receptacle. Leave about eight inches of cord and bundle the rest. Figure 7-99 Plug Cable into Wall Plug the opposite end of the line cord into the DCL-60-1...
  • Page 305 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 SECTION 6 BLUETOOTH CORDLESS HANDSET 6.1 Bluetooth Cordless Handset (BCH) Interface This optional interface allows the multiline terminal user to use Bluetooth technology to provide a cordless handset. This handset provides: ...
  • Page 306 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 6.2 Selecting a Location Before choosing a location for your new telephone, consider these important guidelines:  If multiple cordless terminals are installed, keep their Bluetooth cradles at least 3.3 feet (1meter) apart from one another.
  • Page 307 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Controls and Indicators Controls and indicators can be found in Figure 5-101 Bluetooth Cradle Controls and Indicators Figure 5-102 Bluetooth Handset Controls and Indicators on page 5-83. Figure 5-101 Bluetooth Cradle Controls and Indicators...
  • Page 308 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 5-102 Bluetooth Handset Controls and Indicators System Hardware Manual 5-83...
  • Page 309 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Installing the Bluetooth Cordless Handset The BCH-L (BK) UNIT is an optional device that transforms the standard multifunctional telephone into a cordless terminal. This section explains how to transform the standard hand-set into a BCH-L (BK) UNIT. The BCH-L (BK) UNIT cannot be connected to the DTL-2E-1( ) or DTL-6DE-1( ) telephones.
  • Page 310 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 5-104 Remove Legs From multiline terminal Remove the side panel. Disconnect serial connection cord from terminal body. Leave cord connected to the cradle unit. Push the latch to the right to unlock the cradle unit. Then push...
  • Page 311 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Insert the cradle connecting cable of the Bluetooth Cradle (BTC) into the unit connector. Figure 5-106 Attach Bluetooth Cradle to the multiline terminal Fit the projections on the side of the Bluetooth Cradle into the...
  • Page 312 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Remove the connector cover (rubber) from the bottom of the multiline terminal. Figure 5-108 Removing the Connector Cover Insert the lower claws of the Bottom Unit (see Figure 5-109 Installing the Bottom Unit) into precut holes on the multiline terminal.
  • Page 313 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Push the latch to release the cover (see Figure 5-110 Stowing the Bottom Unit Cable). Stow the extra bottom unit connecting cable and close the cover. Figure 5-110 Stowing the Bottom Unit Cable Cut or trim the supplied coupled device for the tilt legs handset option.
  • Page 314 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Reinstall the legs, pushing upwards until both locks snap into place. Set tilt legs to desired position. Return the multiline terminal to the numbered keypad in the up position. Connect the Line cord and the AC adapter.
  • Page 315 Wall Mounting the Bluetooth Cradle To prevent possible damage to the BCH-L (BK) UNIT due to falling, NEC recommends installing the unit in a firm position so it will not fall due to its own weight. Clearances required for installing the Bluetooth cradle are shown below.
  • Page 316 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 5-114 Installing Wood Screws Remove the Bluetooth hanger from the cradle. With a screwdriver, pry from the bottom, and lift the handset hanger from the cradle. Rotate the hanger top to bottom. Slide it downward in the hollow until it clicks into position.
  • Page 317 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Turn multiline terminal upside down. Lower the tilt leg to the first position (refer to Figure 5-116 Separate Tilt Leg from Leg Support). Figure 5-116 Separate Tilt Leg from Leg Support Hook the wall mount holes (C and D) on the back of the terminal on wood screws (c and d) installed.
  • Page 318 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 6.4.3 Remove and Replace Handset Battery The battery loaded in the Bluetooth handset has a useful life of about two years, depending on how the handset is used. If the battery voltage diminishes quickly after the battery has been charged for a long time, replace with a new Li-ion battery.
  • Page 319 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 SECTION 7 BLUETOOTH HUB ADAPTER Bluetooth Hub Adapter (BHA) Features The BHA-L UNIT adapter connects a Bluetooth device to a multiline terminal. The BHA-L UNIT cannot be connected to the DTL-2E-1( ) or DTL-6DE-1( ) telephone.
  • Page 320 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 5-121 Removing the Connector Cover Insert the lower claws of the Bottom Unit (see Figure 5-122 Installing the BHA-L UNIT) into precut holes on the multiline terminal. Figure 5-122 Installing the BHA-L UNIT Align connector on inside of BHA-L UNIT and push down until unit snaps into place.
  • Page 321 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 7.1.2 Pairing a Bluetooth Device and multiline terminal (Bluetooth Installed) Access the Bluetooth screen from a multiline terminal menu and register the Bluetooth headset with the BHA-L UNIT. 7.1.2.1 Accessing the Bluetooth Device Setup Screen...
  • Page 322 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 7.1.2.4 Connecting the Paired Device Enable the Bluetooth device. Select [2. Enable] in the connection screen. After pairing a Bluetooth device, be sure to configure its connection to enable it. If...
  • Page 323 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 7.1.2.7 BT Information You can view the following kinds of information about the BHA-L UNIT:  Firmware and hardware versions.  Bluetooth module information and standard.  Installed profile versions. ...
  • Page 324 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 SECTION 8 SINGLE LINE TELEPHONE 8.1 Installing the IP1E-1SLTAD The Single Line Telephone adapter provides an interface for Single Line Telephones and other similar devices from an ESI channel. This adapter can be connected to any ESI port.
  • Page 325 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 5-130 Connecting the IP1E-1SLTAD 8.2 Wall-Mounting the IP1E-1SLTAD Unplug the two line cords from the IP1E-1SLTAD. Remove the two screws from the front of the IP1E-1SLTAD. Lift the cover off the adapter.
  • Page 326 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Using the two screws provided with the IP1E-1SLTAD, attach the back cover to the desired location. Figure 5-132 Attaching the Unit Replace the front cover and the two screws removed in Step 2.
  • Page 327 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 - - NOTES - - Installing DT300/DT700 Series (DTL/ITL) Digital and IP Multiline Terminals 5-102...
  • Page 328 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Chapter6; Installing SV8100 Optional Equipment SECTION 1 GENERAL INFORMATION This chapter provides information for installing optional equipment, such as IP1WW-2PGDADs, background music, door boxes, DSS consoles, Dterm VSR, external paging as well as other handsets, recording devices and adapters on the SV8100 digital and IP telephones.
  • Page 329 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 The IP1WW-2PGDAD connects to any available digital extension port. The terminal connections made in the IP1WW-2PGDAD and the jumper settings determine what features are used for each circuit. Figure 6-1 IP1WW-2PGDAD 2.2 LED Indications...
  • Page 330 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 1. Remove the screw from the front of the IP1WW-2PGDAD. Figure 6-2 Remove Cover from IP1WW-2PGDAD 2. Using a screwdriver, break out the plastic piece covering the cable hole. Figure 6-3 Remove Plastic Cover from Cable Hole...
  • Page 331 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Table 6-2 IP1WW-2PGDAD S3 . S6 Jumper Settings Function LED Indication Open Open Door Box On when in use. Channel 1 Open Short External Paging Speaker On when in use. Short...
  • Page 332 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Strip one end of the cable to be connected to the control relay or door box so that approximately 1/4” (8 mm) of bare wire is exposed. Insert the cable into the proper CN4 or CN5 location while holding down the lock button (holding down this lock button is easiest with a flat-head screwdriver).
  • Page 333 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 6-5 IP1WW-2PGDAD Connection Diagram Installing SV8100 Optional Equipment...
  • Page 334 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 6-6 Connecting Cable to the IP1WW-2PGDAD Repeat Steps 4 and 5 for any additional connections required. Replace the cover and tighten the screw to hold the cover in place. If required for the function being used, insert the RCA connectors into the CN2 (Channel 1) and CN3 (Channel 2) connectors on the back of the IP1WW-2PGDAD.
  • Page 335 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 6-7 IP1WW-2PGDAD Connections Install a modular jack for each IP1WW-2PGDAD. For each module, run one-pair 24 AWG station cable from the cross-connect block to a modular jack. Ground the unused pair.
  • Page 336 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 In some cases, when testing the operation of an extension port when connecting to a IP1WW-2PGDAD, a technician may connect a line cord directly from an extension port on the CD-8DLCA/CD-16DLCA Blade.
  • Page 337 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 14. The back of the IP1WW-2PGDAD has two key-hole type openings. Place the IP1WW-2PGDAD over the two screws and slide it down or over (depending on the positioning) to lock it in place.
  • Page 338 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 SECTION 3 BACKGROUND MUSIC 3.1 Installing Background Music Background Music (BGM) sends music from a customer-provided music source to speakers in multiline terminals. If an extension user activates it, BGM plays when the user’s extension is idle.
  • Page 339 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 SECTION 4 DOOR BOX 4.1 Installing a Door Box An IP1WW-2PGDAD is required for this option. The Door Box is a self-contained, water-resistant, Intercom unit typically used to monitor an entrance door. A visitor at the door can press the Door Box call button (like a door bell).
  • Page 340 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 If wall mounting the Door Box, remove the screw on the front of the Door Box. Remove the back half of the Door Box and attach this mounting bracket to the wall with the two screws provided.
  • Page 341 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 6-11 Setting the IP1WW-2PGDAD for a Door Box 6-14 Installing SV8100 Optional Equipment...
  • Page 342 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 6-12 Installing a Door Box System Hardware Manual 6-15...
  • Page 343 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 SECTION 5 EXTERNAL PAGING External Page Two external page zone/door box circuits are provided by each IP1WW-2PGDAD installed. Each Door Box/external page circuit provides a dry relay contact. The CD-CP00 also provides a connection for external paging and a relay. The external page on the CD-CP00 is speaker number 9 - the relay is number 0.
  • Page 344 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 6. Plug a modular line cord from the mod jack to the CN1 connector on the IP1WW-2PGDAD. 7. Connect the two-conductor station cable from the CN5 connectors within the IP1WW-2PGDAD to the external relay/external page.
  • Page 345 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 The IP1WW-2PGDAD provides amplifiers for each page output port (for a maximum of +8 dBm, 600 ohms at 1 KHz). No additional page amplification is provided by the IP1WW-2PGDAD but, if required, an external page amplifier can be used for additional amplification.
  • Page 346 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Door Box /External Page Relay Contacts 6.2.1 Connecting a Contact Relay Device to a Door Box/External Page Relay To connect a dry contact relay device to a Door Box/External Page Relay:...
  • Page 347 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 The relay closes when the Door Box/external page zone is called. The maximum applied voltage is 24vDC at .5A for each contact. Figure 6-14 CD-CP00 Page Connections SECTION 7 EXTERNAL RECORDING SYSTEM / EXTERNAL RINGER...
  • Page 348 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Installing an External Recording System or External Ringer To connect to the IP1WW-2PGDAD: Make sure the jumper in the IP1WW-2PGDAD for the channel is set correctly. (Refer to Figure 6-4 IP1WW-2PGDAD Jumper Settings on page 6-4).
  • Page 349 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 6-15 IP1WW-2PGDAD Cable Connection Programming  10-03-01: ETU Setup. Terminal Type (Circuit 1) 10-03-06: ETU Setup. Terminal Type (Circuit 2) Confirm that the IP1WW-2PGDAD has defined the circuit as either type 7 for External Ringer or 9 for ACIs.
  • Page 350 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100  11-08-01: ACI Group Pilot Number Assign pilot numbers to ACI groups. When a user dials the pilot number, they reach an available ACI software port in the group. ACI Groups 1-16 ...
  • Page 351 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 destination in Program 15-12 will be followed.  15-12-02 : Conversation Recording Destination for Extensions - ACI Automatic Recording for Incoming Call Determine whether an extension should be automatically recorded when an incoming call is received (0=off, 1=on).
  • Page 352 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 SECTION 8 MUSIC SOURCES Music on Hold The system can provide Music on Hold from either an internally synthesized source on the CD-CP00 or from an external source. The external MOH can be a tuner, tape deck, CD player, etc.
  • Page 353 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Install bridging clips as required. Plug a modular line cord from the mod jack to the CN1 connector on the IP1WW-2PGDAD. Connect an RCA jack to the audio output(s) on the back of the IP1WW-2PGDAD.
  • Page 354 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 6-17 IP1WW-2PGDAD Connections System Hardware Manual 6-27...
  • Page 355 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 SECTION 9 TELEPHONE LABELING 9.1 DESI Printer Sheets Telephones can be easily labeled by removing the plastic faceplate. These labels can be printed by hand, typewriter, or printing DESI labels. Labels for this are on 8 1/2 x 11”...
  • Page 356 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 SECTION 10 TELEPHONE ADAPTERS 10.1 Using Adapters The modular terminals can support installing one additional adapter underneath the terminal. These adapters provide the multiline terminal different abilities, depending on the adapter installed.
  • Page 357 ILPA does the negotiation and detection with the switch and then relays the power to the IP terminal device. This provides an additional way to power the NEC IP terminals. With this adapter, the IP terminals on the UNIVERGE SV8100 system can be powered using: ...
  • Page 358 SW1 Setting IEEE802.3af STD System Cisco Discovery Protocol System NEC BlueFire 210/24 Switch (US Only) Set the switch setting on the NEC IP Phone or IP adapter to the correct position. IP Phone (SW2) or IP Adapter (SW1) SW Setting...
  • Page 359 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Connect the NEC VoIP telephone to the TEL connector on the ILPA-R adapter with the LAN cable provided with the adapter.  If a customer-provided cable is used, the total length from the switch to the telephone should be less than 328 feet.
  • Page 360 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 10.3 ADA-L UNIT Using the ADA-L UNIT (Ancillary Device Adapter) provides a recording jack connection from a telephone to an external tape recorder, speaker or PC. Both sides of the conversation are recorded. The adapter output is a 1/8” audio (stereo) jack which you can connect directly to an AUX level input on a recorder or page amplifier.
  • Page 361 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 10.3.1 ADA-L UNIT Switch Settings Figure 6-23 ADA-L UNIT shows the location of the switches. The DIP Switches (DSW) allow a technician to configure the unit for specific settings. Due to location, set switches prior to installation of ADA-L on DTL/ITL multiline terminal.
  • Page 362 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 To provide control to the recorder or to enable/disable the record start warning tones, refer to Table 6-3 ADA-L Unit Switch Settings. Table 6-3 ADA-L Unit Switch Settings Switch Description/Settings Record Confirmation Tone...
  • Page 363 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 10.3.2 Installing the ADA-L UNIT Perform the following steps to connect the ADA-L UNIT to the Bottom Option Interface located underneath the DTL/ITL multiline terminal. Only one ADA-L UNIT can be installed at a time.
  • Page 364 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 4. Push the two stopper tabs through the slots to separate the tilt leg from the leg support. 5. Lay the tilt leg and the leg support flat to expose ADA-L UNIT compartment.
  • Page 365 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 10.3.3 ADA-L UNIT Connection The mini-plug connection cord should not use an attenuator and have a monaural (single ring) mini-plug connection for normal recording. 10.3.3.1 ADA-L UNIT Connection for Recording Only 1.
  • Page 366 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 10.3.3.2 ADA-L UNIT Connection for Sending Recorded Calls to the Telephone 1. Set the ADA-L UNIT DSW switches (see Figure 6-23 ADA-L UNIT on page 6-34).  Set DSW 6 to ON.
  • Page 367 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 10.4.1 APR-L UNIT Switch Settings Figure 6-29 APR-L UNIT shows the location of the switches. The DIP Switches (DSW) allow a technician to configure the unit for specific settings. Due to location, set the switches prior to installation of APR-L on DTL multiline terminal.
  • Page 368 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 3. Lower the tilt leg to the first position (refer to Figure 6-30 Separate Tilt Leg from Leg Support). Figure 6-30 Separate Tilt Leg from Leg Support 4. Push the two stopper tabs through the slots to separate the tilt leg from the leg support.
  • Page 369 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 6-32 Install APR-L UNIT 8. Return tilt leg to original position. 9. For the APR adapter to be recognized correctly, before plugging in the multiline terminal, make sure the extension number to be used for the adapter is undefined in Program 10-03-01.
  • Page 370 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 10.5 PSA-L (BK) UNIT / PSA-L (WH) UNIT The PSA-L UNIT (Power Save Adapter), an optional adapter for the ITL/DTL Terminals, is used with IP telephones to make or receive a call using the Public Switched Telephone Network (PSTN) when a call cannot be made or received using the Local Area Network (LAN).
  • Page 371 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 6-34 PSA-L UNIT Connections 10.5.1 Installing the PSA-L Adapter Before installing or removing the PSA-L adapter, remove the line cord, LAN cable, and then AC adapter from the outlet. 1. Turn multiline terminal upside down.
  • Page 372 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 6-35 Separate Tilt Leg from Leg Support Push the two stopper tabs through the slots to separate the tilt leg from the leg support. Lay the tilt leg and the leg support flat.
  • Page 373 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 8. Push latch to right to unlock the cradle unit. Then push the cradle unit forward to separate from the terminal body. Figure 6-37 Bottom of Multiline Terminal (Legs Removed) 9. Fit the projections on the side of the PSA-L UNIT into the guide holes on the side of the terminal and pull toward you until the PSA-L UNIT snaps into place.
  • Page 374 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 10. Gently press the serial cable into the grooved cutout for the cable. Figure 6-39 Grooved Cutout for Serial Cable 11. Connect the serial connection cord (refer to Figure 6-38 Attach PSA-L...
  • Page 375 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 14. For the Handset, set the connector in place. Figure 6-41 Insert Connector for Handset Use 15. If using the handset, install the handset cable (refer to Figure 6-42 Insert Handset Cable).
  • Page 376 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 16. Attach the analog trunk cable and the handset cable. Refer to Figure 6-34 PSA-L UNIT Connections on page 6-44. 17. Install the legs, pushing upwards until both locks snap into place.
  • Page 377 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 22. Pull tab down and lift out the numbered keypad panel. Figure 6-44 Remove Numbered Keypad 23. Install the new keypad panel supplied with the PSA-L UNIT. Figure 6-45 Install Numbered Keypad 24.
  • Page 378 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 Figure 6-46 Install Plastic Panels 25. Connect the line cord to the adapter. 26. Connect the user system (KTS or PBX) cable. 27. If required, remove the side panel from the original cradle unit.
  • Page 379 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 3. Adjusting the Ring Volume Use the Volume Control Switch located on the PSA-L adapter to adjust through the three available volume levels.  Other than receiving calls, no other terminal function is available.
  • Page 380 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 When connecting the RJ-61 cables to the COIU Blade, note the position of the Power Failure connector. Do not confuse connector CN3 as the CN2 trunk connector. 11.2 Connector Pin-Outs on COIU Blade for Power Failure Circuits...
  • Page 381 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn UNIVERGE SV8100 (PZ-4COTE) Figure 6-47 Power Failure Connector (CN3) Shown on CD-4COTA Blade 6-54 Installing SV8100 Optional Equipment...
  • Page 382 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn NEC Infrontia Corporation, Issue 2.0...

Table of Contents