Trouble Shooting - RIDGID CountPlus Operator's Manual

Cable counter
Table of Contents

Advertisement

Trouble Shooting

PROBLEM
No power to SeeSnake
connector.
Camera video image
Connections faulty.
not seen.
CountPlus battery low.
Settings incorrect for reel or
cable being used.
Count accuracy
seems unreliable.
Counting from a zero point
other than the one intended.
Battery dead or near-dead.
Low Battery warning
appears.
Physical cable measurement
The symbol "+"
appears after the on-
has exceeded the cable
screen distance
parameter in settings.
measurement.
PROBABLE FAULT
LOCATION
Ridge Tool Company
SeeSnake CountPlus Cable Counter
SOLUTION
Check power is correctly plugged in.
Check switch on SeeSnake monitor.
Check alignment and pins of connection to monitor or DVR
unit from SeeSnake.
Check orientation, seating, and pin condition in the
CountPlus connection per Appendix A.
Replace 3-volt battery in the CountPlus (CR2450).
Verify the settings are correct for the SeeSnake cable length,
cable diameter and reel type you are using.
Confirm you are measuring from the intended zero-point.
Replace 3-volt battery in the CountPlus (CR2450).
Verify the actual length of your installed cable; re-set the reel
and cable settings for the correct reel type and actual cable
length and diameter as described on page 7.