1∗45 EXIT DELAY SOUNDING
1=enable; 0=disable; Produces quick beeping during exit
delay if enabled.
NOTE: Must be "1" for UL/ULC installations.
NOTE: See page 32, "SOUND OPTION", prompt for
disabling the entry/exit beeps on individual
keypads.
(Option not displayed in SIA, always enabled.)
1∗47 CHIME ON EXT. SIREN
1=enable; 0=disable
1∗52 SEND CANCEL IF ALARM + OFF
1=no restriction; 0=within Bell Timeout period only
1∗76 ACCESS CONTROL RELAY BY PART.[00]
Relay will be pulsed for 2 seconds whenever code + [0] is
pressed. Enter 00-96; 00=none.
Must be "00" for UL installations.
3rd Page Fields
2∗05 AUTO-ARM DELAY
Enter the time between the end of the arming window and
the start of auto-arming warning period, in values of 1-14
times 4 minutes 00=instant; [15=no auto arm at all]. When
this delay expires, the Auto-Arm Warning Period begins.
2∗06 AUTO-ARM WARNING PERIOD
This is the time during which the user is warned to exit the
premises prior to the auto-arming of the system (beeps
every 15 seconds; "ALERT" displayed). Enter 01-15
minutes. 00=instant at end of arming delay.
2∗07 AUTO-DISARM DELAY
This is the time between the end of the disarming window
and the start of auto-disarming. Enter 01-14 times 4
minutes; 00=instant at end of window; 15=no auto-disarm
2∗08 ENABLE FORCE ARM FOR AUTO-ARM
0=disable; 1=enable
[1]
2∗09 OPEN/CLOSE REPORTS BY EXCEPTION [0]
A
E
1=enable; 0=disable; If enabled only openings and
closings occurring outside the scheduled opening/closing
windows will trigger dialer reports. Opening reports will
also be suppressed during the closing window, in order to
prevent false reports when the user arms the system and
then re-enters the premises to retrieve a forgotten item.
2∗10 ALLOW DISARMING ONLY DURING
[0]
ARMING/DISARMING WINDOWS
A
E
See system-wide field 2∗11 if enabling field 2∗10. This
feature adds high security to the installation.
[1]
0=disable; 1=enable
A
E
2∗18 ENABLE GOTO FOR THIS PARTITION
1=Allow log-on from other partitions; 0=disable
|
A
E
2∗22 DISPLAY FIRE ALARMS OF
OTHER PARTITIONS
0=No; 1=Yes
2∗23 DISPLAY BURG, PANIC AND CO
|
ALARMS OF OTHER PARTITIONS
[15]
A
E
0=No; 1=Yes
2∗24 DISPLAY TROUBLES OF OTHER
PARTITIONS
0=No; 1=Yes
|
[15]
SUMMARY OF PROGRAMMING COMMANDS
A
E
• To enter program mode, enter installer code + [8] + [0]
+ [0] + [0]
• To set standard defaults, press ∗97
|
[15]
• To change to next page of program fields, press ∗94
A
E
• To return to previous set of fields, press ∗99
• To erase account and phone number field entries,
press [∗] + field number + [∗]
• To assign zone descriptors, press #93 + follow menu
[0]
A
E
prompts
• To add custom words, press #93 + follow menu
prompts
• To enter Installer's Message, press #93 + follow menu
prompts
• To exit program mode, enter ∗99 OR ∗98: ∗99 allows
re-access to programming mode by installer code. ∗98
prevents re-access to programming mode by installer
code. Note that if local programming lockout is set via
downloading, programming mode cannot be entered at
the keypad. In the event that local programming is
required after the lock-out, setting the location in
Compass will open a 24-hour window for programming
when the Master code + #65-command is entered. The
24-hour window counts down and then locks out local
programming until the next Master code + #65-
command is entered.