General Specifications - Honeywell Series 3000 MkII Technical Manual

Gas detector
Hide thumbs Also See for Series 3000 MkII:
Table of Contents

Advertisement

SERIES 3000 MKII TECHNICAL MANUAL

17. General specifications

Series 3000 MkII Detector
Use
Rugged and reliable gas detector for the protection of personnel from toxic and oxygen gas hazards. Suitable for use
in European Zone 1 or 2 or 21 or 22 hazardous areas and North American Division 1 or 2 areas.
Detectable Gases & Performance (See notes below)
Selectable Full
Gas
Scale Range
Oxygen
25.0%/Vol only
Hydrogen Sulfide
10.0 to 50.0ppm
Hydrogen Sulfide
50 to 500ppm
Carbon Monoxide
100 to 500ppm
Sulfur Dioxide
5.0 to 20.0ppm
Ammonia
50 to 200ppm
Ammonia
200 to 1,000ppm
Chlorine
5.0 to 20.0ppm
Chlorine Dioxide
1.00ppm only
Nitric Oxide
100ppm only
Nitrogen Dioxide
5.0 to 50.0ppm
Hydrogen
1,000ppm only
Hydrogen
9,999ppm only
Hydrogen Chloride
10.0 to 20.0ppm
Hydrogen Cyanide
30.0ppm only
Hydrogen Fluoride
12.0ppm only
Ozone
0.4ppm only
Phosphine
1.2ppm only
Electrical
2 wire loop powered
Connections and
17Vdc (+/-10%) to 32Vdc (max.)
Power
22mA max. overrange
Recommended
2 wire with screen (90% coverage) or conduit.
Cable
0.5mm
0-100% FSD 4-20mA
Max. overrange 22mA
Signal
Inhibit = Selectable 3mA (fault) or 4mA for toxic sensors or 3mA (fault) or 17.4mA for oxygen sensors.
Fault = 3mA
Construction
Material
Transmitter: Epoxy painted aluminium alloy LM25 or 316 Stainless Steel. Sensor: 316 Stainless Steel with PTFE filter
Entries
2 x M20 (for ATEX/IECEx Approval) or 2 x 3/4NPT (for UL Approval)
Maximum
164 x 201 x 99mm
6.4 x 7.9 x 3.9 inches
Dimensions
Aluminium alloy LM25 : 1.7kg (3.75lbs.)
Weight
Stainless Steel 316: 3.7kg (8.16lbs.)
Environmental
IP Rating
IP66 (EN 60529). NEMA 4X (Not tested by UL but by another Third Party Laboratory)
ATEX/IECEX: -20°C to +55°C (-4°F to +131°F)
Certified Operating
UL/cUL: -40°C to +55°C (-40°F to +131°F)
Temperature
Continuous 20-90%RH (non condensing)
Operating Humidity
Intermittent 0-99%RH (non condensing)
Operating
90-110kPa
Pressure
Transmitter:15°C to 30°C (59°F to 86°F) 30-70% RH (non condensing)
To ensure the optimum operational life of electrochemical cell sensors, replacement cells should be stored
Storage Conditions
in sealed packaging in cool dry conditions and preferably kept refrigerated at temperatures between 0 and
20 degrees C.
Transmitter: UL/c-UL Class I, Div. 1 & 2, Groups B, C & D; Class II, Div. 1 Groups E, F & G, Class II, Div.
2, Groups F & G; Class I, Zone 1, Group IIB + H2 Hazardous Locations.
Remote Sensor Accessory: UL/c-UL = Class I, Div. 1, Groups A, B, C & D; Class II Division 1 & 2, Groups
E, F & G; Class 1, Zone 0, Group IIC; Class II, Zone 20
Certification
Transmitter: ATEX:
Remote Sensor Accessory: ATEX: II 1GD Ex ia IIC T4 Ga Ex ia IIIC T135ºC Da
Transmitter: IECEx Ex d [ia IIC Ga] IIB + H2 T4 Gb Ex t [ia IIIC Da] IIIB T135ºC Db
Remote Sensor Accessory: IECEx: Ex ia IIC T4 Ga Ex ia IIIC T135ºC Da
CE compliant in accordance with:
Approvals
ATEX Directive 94/9/EC
EMC Directive 2004/108/EC (EN50270:2006)
Notes: Detection performance is temperature and humidity dependent. Listed data is based at 20°C, 50% RH only.
Response time is longer when operating in colder temperatures.
*When operating in Hazardous Area applications the detector must not be operated outside the certified temperature
range. See Certification details for UL, c-UL and ATEX/IECEx certified temperature ranges.
Default
Selectable Cal
Steps
Range
Gas Range
25.0%VOL
n/a
20.9%/Vol
(Fixed)
15.0ppm
0.1ppm
100ppm
10ppm
300ppm
100ppm
15.0ppm
5.0ppm
200ppm
50ppm
1,000ppm
50ppm
5.0ppm
5.0ppm
30 to 70% of
1.00ppm
n/a
selected full
100ppm
n/a
scale range
10ppm
5.0ppm
1,000ppm
n/a
9,999ppm
n/a
10ppm
1.0ppm
30.0ppm
n/a
12.0ppm
n/a
0.4ppm
n/a
1.2ppm
n/a
(20AWG) to 2.0mm
(14AWG) Max.
2
2
II 2 (1) GD Ex d [ia IIC Ga] IIB + H2 T4 Gb Ex t [ia IIIC Da] IIIB T135ºC Db
S3KMKIIMAN_MAN0878_Issue 6_01/2014
Response
Accuracy
Default
Time
(ppm or % of
Cal Point
(T90)
applied gas)
secs
20.9%/
15
+/-0.5% O2
Vol
10ppm
30
+/-0.3 or +/-20% <0.5ppm/
50ppm
30
+/-2 or +/-20%
100ppm
30
+/-2 or +/-20%
5.0ppm
40
+/-0.3 or +/-20%
100ppm
180
+/-10 or +/-20% <5%/6 mo -20°C / -4°F 40°C / 104°F1
300ppm
180
+/-15 or +/-20% <5%/6 mo -20°C / -4°F
2.0ppm
90
+/-0.3 or +/-20% <2ppm/yr -10°C / 14°F
0.5ppm
120
+/-30%
50ppm
50
+/-3 or +/-20%
5ppm
60
+/-3 or +/-20%
500ppm
90
+/-10 or +/-25%
5000ppm
90
+/-25 or +/-30%
5.0ppm
150
+/-1 or +/-20%
10.0ppm
80
+/-3 or +/-20%
5.0ppm
300
+/-30%
0.2ppm
TBD
+/-0.02 or +/-20% <5%/6 mo -20°C / -4°F
0.5ppm
33
+/-0.03 or +/-20% <10%/yr
34
Operating Temperature*
Drift over
time
Min
Max
<4%/yr
-30°C / -22°F 55°C / 131°F
-40°C / -40°F 55°C / 131°F
yr
<0.5ppm/
-40°C / -40°F 55°C / 131°F
yr
<2ppm/yr -40°C / -40°F 55°C / 131°F
<2%/mo
-40°C / -40°F 55°C / 131°F
40°C / 104°F
55°C / 131°F
<5%/yr
-20°C / -4°F
55°C / 131°F
<2%/mo
-20°C / -4°F
55°C / 131°F
<2%/mo
-20°C / -4°F
55°C / 131°F
<2%/mo
-20°C / -4°F
55°C / 131°F
<10%/6
-20°C / -4°F
55°C / 131°F
mo
<20%/yr
-20°C / -4°F
40°C / 104°F
<3%/mo
-20°C / -4°F
55°C / 131°F
<20%/yr
-20°C / -4°F
55°C / 131°F
40°C / 104°F
-20°C / -4°F
40°C / 104°F
+55C intermittent
1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents