Specifications - Sharp AH-A129E Service Manual

Table of Contents

Advertisement

AH-A129E
AU-A129E
ITEMS
Cooling capacity
Moisture removal
Electrical data
Phase
Rated frequency
Rated voltage range
Rated voltage
Rated current
Cool
Rated input
Cool
Compressor
Type
Model
Oil charge
Refrigerant system Evaporator
Condenser
Control
Refrigerant volume
Capillary tube size
Outer dia. mm
Inner dia. mm
Lenght
Q'ty
Noise level
High
Med.
Low
Fan system
Drive
Air flow quantity
High
(at cooling)
Med.
Low
Fan
Connections
Refrigerant coupling
Refrigerant tube size Gas, Liquid
Refrigerant pipe sets No.
Drain piping mm(Inches)
Others
Safety device
Air filters
Net dimensions
Width
Height
Depth
Net weight
Note: The condition of star(

SPECIFICATIONS

INDOOR UNIT
AH-A129E
kW
3.45
Liters/h
1.3
Single
Hz
50
V
198 to 264
V
220 - 240
A
5.3 - 5.1
W
1150 - 1180
Hermetically sealed rotary type
RH207VXET
520cc (DIAMOND MS56))
Louver fin and Grooved tube type(7mm tube)
Louver fin and Grooved tube type(7mm tube)
Capillary tube
940g
mm
dB(A)
42
dB(A)
40
dB(A)
36
Direct drive
3
m
/min.
9.3
3
m
/min.
8.4
m
3
/min.
7.0
Cross flow fan
Flare type
1/2", 1/4"
AZ-24T7F; 7m(23ft)
O.D ø 18(45/64)
Compressor: Overload protector(Internal)
Fan motors: Thermal fuse
Fuse, Micro computer control
Polypropylene net (Washable)
mm
897
mm
297
mm
186
kg
10
) marked item are 'IEC378'.
2.7
1.6
700
1
48
Direct drive
26
Propeller fan
720
535
236
35
2
OUTDOOR UNIT
AU-A129E