Test Program - Yamaha CS1D Service Manual

Hide thumbs Also See for CS1D:
Table of Contents

Advertisement

CS1D
4.
Noise
· For details on the connection method etc., refer to the Test Program Specifications KES-92654.
· Since a 2 track in digital coaxial 1,2 receiver has been selected in 1,2, use a coaxial cable ( 50 , 50m ) for the connection for
those terminals.
· Output 03D oscillation 1 kHz to ST OUT and YGDAI SLOT.
(1) Fs = 51.12 kHz (48 kHz + 6.5 %)
· Set the function generator to 51.12 kHz.
· Test listen with headphones for 30 seconds and verify that there is no noise.
· Change the connection between the DIGITAL I/O CONSOLE terminal and the DIGITAL I/O ENGINE terminal.
(2) Fs = 39.69 kHz (44.1 kHz -10 %)
· Set the function generator to 39.69 kHz.
· Test listen with headphones for 30 seconds and verify that there is no noise.
· Change the connection between the DIGITAL I/O CONSOLE terminal and the DIGITAL I/O ENGINE terminal and check
again.
5.
DC POWR INPUT B check
· Use DC power input B and check that CS1D can start.
The LCD initial screen should be displayed.
6.
FIFO check
Refer to the following preparation methods and prepare the software version to be used.
Software used:
FIFO inspection
Version used:
Files composed using a PM1D SYSTEM SOFTWARE with a version later than the version
shown on the cover. (Managed with the already drawn CD-R assembly drawing (3JL-XY714A0).
Method of preparation: Follow the instructions in the CS1D test program specifications (Drawing No: KES-92654) titled
"Procedure for extracting software groups for production and customer service applications".
Once the files have been extracted, refer to the Readme.txt in the FIFODiag directory.
Connection
CS1D
6-1.
Check between EIF-PCIF
1. On the [UTILITY]-[PREFERENCE] screen, set mouse tapping to off and start the check program.
2. After setting mouse tapping to off, confirm that the display below is shown in red at the bottom of the screen.
Note: If the display is different than the one shown above, reset using mouse tapping on, restart and then set to off.
3.
Confirm that there is no change in the display 30 minutes after starting the program.
4. Reinsert the CS1D connection in the engine B1 side and switch to mirror mode using the SYS/W clock system connection screen.
Then select engine B and confirm in the same way.
Check between EIF - PNC1 ( Can be performed simultaneously with the inspection in 6-1 )
6-2.
1. While pressing the shift key on the panel, press the scene memory input key 4 and start the check program.
2. Check that the time code display section is the display shown below.
Note:) If the display is different than the one shown above, reset while pressing the shift key and restart.
3. While pressing the shift key on the panel, press the scene memory input key 4 and start the check program.
4. Check that the time code display section is the display shown below.
102
software
in PM1D system software
OUT
ENGINE A1
IN
00_00_00_00_00_00_00_00_00_00 ( All 0 )
00_00_00_00 ( All 0 )
CONTROL I/O (BNC)
CONTROL I/O (BNC)
DSP1D
IN
OUT

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents