Rmon History Table - Cisco 350XG series Administration Manual

10g stackable managed switches
Table of Contents

Advertisement

Status and Statistics
RMON
STEP 1
STEP 2
STEP 3
STEP 4
STEP 5
STEP 1
STEP 2
Cisco 350XG & 550XG Series 10G Stackable Managed Switches
To enter RMON control information:
Click Status and Statistics > RMON > History. The fields displayed on this page
are defined in the Add RMON History page, below. The only field is that is on this
page and not defined in the Add page is:
Current Number of Samples—RMON is allowed by the standard to not
grant all requested samples, but rather to limit the number of samples per
request. Therefore, this field represents the sample number actually granted
to the request that is equal or less than the requested value.
Click Add.
Enter the parameters.
New History Entry—Displays the number of the new History table entry.
Source Interface—Select the type of interface from which the history
samples are to be taken.
Max No. of Samples to Keep—Enter the number of samples to store.
Sampling Interval—Enter the time in seconds that samples are collected
from the ports. The field range is 1-3600.
Owner—Enter the RMON station or user that requested the RMON
information.
Click Apply. The entry is added to the History Control Table page
Configuration file is updated.
Click History Table (described below) to view the actual statistics.

RMON History Table

The History page displays interface-specific statistical network samplings. The
samples were configured in the History Control table described above.
To view RMON history statistics:
Click Status and Statistics > RMON > History.
Click History Table.
4
,
and the Running
51