Hitachi wj200 series Quick Reference Manual page 55

Hide thumbs Also See for wj200 series:
Table of Contents

Advertisement

Main Profile Parameters
NOTE:. Parameters marked with " " in A column are accessible even in inverter running.
Parameters marked with " " in B column are accessible even in inverter running when in
the high level access mode, which means that b031 is set to "10".
Func.
Name
Code
F001
Output frequency setting
F002
Acceleration time (1)
F202
Acceleration time (1),
nd
2
motor
F003
Deceleration time (1)
F203
Deceleration time (1),
nd
2
motor
F004
Keypad RUN key routing
"F" Function
Description
Standard default target frequency
that determines constant motor
speed, range is 0.0 / start
frequency to maximum frequency
(A004)
Standard default acceleration,
range is 0.00 to 3600 sec.
Standard default deceleration,
range is 0.00 to 3600 sec.
Two options; select codes:
00...Forward
01...Reverse
55
Defaults
A
B
Initial data
0.00
10.00
10.00
10.00
10.00
00
Units
Hz
s
s
s
s