Installing HiPath 3000
Installing HiPath 3800
4.2.6.7
Connecting Peripherals to the Connector Panels with SIPAC 1 SU
Connectors
The boards should be installed in the cabinets as described in Section 4.2.5. The S30807-
Q6631-X connector panels attached to the SIVAPAC connectors on the backplane have two
SIPAC 1 SU connectors each.
Figure 4-35
HiPath 3800 - Connector Panel with Two SIPAC 1 SU Connectors (S30807-
Q6631-X)
Danger
7
Be sure to connect the main protective earthing terminal on all system cabinets to
the grounding point of the electrical building installation before connecting up the pe-
ripherals (for example, potential equalization bus).
The system may only be started (connected to the power supply) if all system cabi-
nets are sealed at the rear with the connection and filler panels provided.
Use the CABLUs that are listed in the following table to establish the connection with the
MDFU-E or an external patch panel. See also Section 4.2.7, "Using an External Main Distribu-
tion Frame or External Patch Panel".
In special cases where the prefabricated CABLUs cannot be used, open-end cables should be
used.
4-62
Cables and connectors for ports 17 - 24
Cables and connectors for ports 1 - 16
P31003-H3550-S403-4-7620, 02/05
HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual