INSTRUCTION MANUAL
Pressure Sensor
DP-100 Series
Thank you for purchasing products from Panasonic Electric Works SUNX
Co., Ltd. Please read this Instruction Manual carefully and thoroughly for
the correct and optimum use of this product. Kindly keep this manual in a
convenient place for quick reference.
WARNING
• Never use this product as a sensing device for personnel protection.
• In case of using sensing devices for personnel protection, use
products which meet laws and standards, such as OSHA, ANSI or
IEC etc., for personnel protection applicable in each region or
country.
• DP-100 series is designed for use with non-corrosive gas. It cannot
be used for liquid or corrosive gas.
• Japanese Measurement Laws prohibit the use of this product in
Japan.
1
CAUTIONS
This product has been developed / produced for industrial use only.
Use within the rated pressure range.
Do not apply pressure exceeding the pressure resistance value. The
diaphragm will be damaged resulting in faulty operation.
Make sure that the power supply is off while wiring.
Incorrect wiring will damage the sensor.
Verify that the supply voltage including the ripple is within the rating.
If power is supplied from a commercial switching regulator, ensure that
the frame ground (F.G.) terminal of the power supply is connected to an
actual ground.
In case noise generating equipment (switching regulator, inverter motor,
etc.) is used in the vicinity of this sensor, connect the frame ground (F.G.)
terminal of the equipment to an actual ground.
Do not use during the initial transient time (0.5s) after the power supply is
switched on.
Do not run the wires together with high-voltage lines or power lines or put
them in the same raceway. This can cause malfunction due to induction.
The specification may not be satisfied in a strong magnetic field.
Avoid dust, dirt, and steam.
Take care that the sensor does not come in direct contact with water, oil,
grease, or organic solvents such as thinners, etc.
Do not insert wires, etc., into the pressure port. The diaphragm will be
damaged resulting in faulty operation.
Do not operate the keys with pointed or sharp objects.
Do not apply stress directly to the sensor cable joint by forcibly bending
or pulling.
SEN TRONIC
AG
Produkte, Support und Service
High-performance Digital Display
For use outside Japan
MEUML-DP100 V1.1
Rugghölzli 2
CH - 5453 Busslingen
.
2
PART NAMES
DP-100
1
2
6
7
8
No.
Part
1
Output 1 opera-
tion indicator
2
Output 2 / analog
voltage operation
indicator
3
Pressure unit dis-
play
4
Main display
5
Sub-display
6
Mode selection
key
7
Up key
8
Down key
9
4-pin male con-
nector
0
Pressure port
3
PIPING
Use a 12mm end wrench (14mm for DP-100-E type) when tightening a
commercial coupler to the pressure port. The tightening torque should be
9.8N·m or less (M5 female connector: 1N·m or less). The commercial
coupler or pressure port section will be damaged if the tightening torque is
excessive.
Wrap sealing tape around the coupler when connecting to prevent leaks.
1
Tel. +41 (0)56 222 38 18
Fax +41 (0)56 222 10 12
3
4
5
Description
Lights up when comparative output 1 is
ON
• Standard
type:
lights
up
comparative output 2 is ON
• Multifunction type: lights up when
analog voltage output is ON
Depending on the model, "MPa" or "kPa"
appears here. If you set another pressure
unit, attach the appropriate label, e.g. psi,
bar, etc.
Large 4-character LCD display.
Small 4-character LCD display.
For details, see page 3, section 8,
SELECTING MODES.
Increases value being set.
Decreases value being set.
See "Pin assignment, 4-pin male connec-
tor" on page 2.
• DP-100 type: R1/8 + M5 female screw
• DP-100-E type: G1/8
+ M5 female
screw
• DP-100-M type: M5 female screw
• DP-100-N type: NPT1/8 + M5 female
screw
12mm end wrench
mailbox@sentronic.com
www.sentronic.com
9
0
when

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic dp-100 series

  • Page 1 IEC etc., for personnel protection applicable in each region or country. Pressure unit dis- Depending on the model, “MPa” or “kPa” • DP-100 series is designed for use with non-corrosive gas. It cannot play appears here. If you set another pressure be used for liquid or corrosive gas.
  • Page 2: Output Mode And Output Operation

    NPN output type MOUNTING  Standard type  Color code of cable with connector The sensor mounting bracket (MS-DP1-1) is available as an option. When mounting the sensor onto the sensor mounting bracket, etc., the (Brown) +V tightening torque should be 0.5N·m or less. (Black) Load Comparative output 1...
  • Page 3: Selecting Modes

    Hysteresis mode Setting condition 2 The comparative output is turned ON or OFF (depending on the N.O./N.C. setting) when the upper or lower threshold is reached and remains ON or EASY (EASY mode) Comparative output 1 set to: OFF until the other threshold is reached. EASY (EASY mode) Comparative output 2 set to: H (Hysteresis)
  • Page 4 Multifunction type To unlock, simultaneously press MODE Press Setting condition 1 MODE Automatic EASY (EASY mode) Comparative output 1 set to: Peak / bottom hold function Analog voltage output / (Analog voltage output) The peak / bottom hold functions display the peak value and bottom value external input: of the fluctuating pressure.
  • Page 5 <Response time setting> MENU SETTING MODE Item Description (2.5ms) (5ms) (5000ms) Comparative output 1 Sets operation of comparative output 1. MODE mode setting <Display color for the main display> Comparative output 2 Sets operation of comparative output 2. mode setting (Standard type only) Red when ON Green when ON...
  • Page 6 <Hysteresis fixed value selection> PRO MODE ・・・・ ・・・・ Item Description (Max.) (Min.) Sub-display selec- Selects what is displayed in the sub-display. MODE • OFF: nothing. tion Standard type only < : Color display scheme> • Unit: pressure unit selected. • No.**: desired number. •...
  • Page 7: Auto-Reference Function

    Code table Procedure, cancel copy function 1 While the slave sensor is disconnected, turn on the power of the master 2nd digit 4th digit 3rd digit sensor. 1st digit High- Standard Standard type type only function type 2 Press MODE for approx.
  • Page 8: Remote Zero-Adjustment Function, Multifunction Type

    REMOTE ZERO-ADJUSTMENT FUNCTION, MODELS, ORDERING INFORMATION MULTIFUNCTION TYPE DP10 The remote zero-adjustment function forcibly sets the pressure value to 1: low pressure type “zero” when the external signal is input. 2: high pressure type The setting value is not corrected when remote zero-adjustment is input. Make sure that the pressure and setting value during remote zero-adjust- Nil: standard type ment do not exceed the pressure range that can be set.
  • Page 9: Specifications

    SPECIFICATIONS Standard type Multifunction type Item Low pressure type High pressure type Low pressure type High pressure type Pressure type Gauge pressure Rated pressure range -100 to + 100kPa -0.1 to +1.0MPa -100 to + 100kPa -0.1 to +1.0MPa Set pressure range -100 to + 100kPa -0.1 to +1.0MPa -100 to + 100kPa...