Honeywell W8665A Manual page 9

Rf receiver module
Table of Contents

Advertisement

W8665E
V8043E
2
3
T (TV)
L8148 / L8124
Fig. 13. Zoned hot water heat using V8043E Zone Valves, an L8148/L8124 Aquastat and a transformer.
W8665E
V8043E
2
3
T (TV)
L8148 / L8124
Fig. 14. Zoned hot water heat and single-zone cooling using V8043E Zone Valves, an L8148/L8124 Aquastat
Y
W
G
Y
1
FACTORY INSTALLED JUMPER.
T
2
CONNECT V8043E YELLOW LEADWIRE TO W8665E.
3
CONNECT V8043E RED LEADWIRES TO L8148/L8124.
Y
W
G
Y
COOLING
CONTACTOR
1
FACTORY INSTALLED JUMPER.
T
2
CONNECT V8043E YELLOW LEADWIRE TO W8665E.
3
CONNECT V8043E RED LEADWIRES TO L8148/L8124.
and a transformer.
W
G
Y
W
G
V8043E
V8043E
2
3
W
G
Y
W
G
FAN
RELAY
V8043E
V8043E
2
3
9
W8665A,E RF RECEIVER MODULE
R C RZ RZ RZ
1
2
3
C
R
R C RZ RZ RZ
1
2
3
C
R
L2
L1
M20688
L2
L1
M20689A
69-1630-1