The settings for the recorder/camera will be different as follows according to how the registration is made ("CAM IP
Auto Addressing" or "Manual Registration").
Setup item
Camera port
Client PC port
Default gateway
WJ-ND300 (A)
HTTP port number
NW camera setup
(Manufacturer, MODEL/COM-
PRESSION, ADDRESS, Port
number)
Live image transmission rate
Rate settings other than the live
image transmission rate
DHCP setting
IP address
Camera
Subnet mask
Gateway
HTTP port number
*1 "CAM IP Auto Addressing" is available only when "OFF" is selected for the DHCP setting of the camera.
*2 The compression method will automatically be applied (JPEG/M-JPEG).
*3 Check if the same IP addresses are not in use already even vacant IP addresses are searched and assigned
automatically. When the message saying that no IP address is available is displayed, check the settings and per-
form "Manual Registration".
When operating the WJ-ND200
It is possible to display the current network settings of the WJ-ND200 using this software.
Refer to the setup instructions (PDF) for how to configure the settings of the network cameras, how to register cam-
eras and how to edit the settings of the registered cameras.
Manual Registration
DHCP setting
Edited value
IP address
Edited value
Subnet mask
Edited value
DHCP setting
Edited value
IP address
Edited value
Subnet mask
Edited value
Edited value
Edited value
Cameras will be registered for
each channel with edited val-
2
ues.*
Fixed at "1 ips"
Default setting
Edited value
Edited value
Edited value
Edited value
Edited value
CAM IP Auto Addressing
1
"OFF" only *
Edited value
Edited value
Edited value
Edited value
Edited value
Edited value
Edited value
Cameras will be registered for
each channel with edited
2
values.*
Fixed at "1 ips"
Default setting
Fixed at "OFF"
Auto incremented value (+1)
starting from the IP address of
the camera port of the recorder *
Same value as for the camera
port of the recorder
Same value as for the default
gateway of the recorder
Fixed at "80"
3