9. RASTER CENTERING CIRCUIT FAILURE

Check the raster control operation
NG
Check the raster control
operation voltage.

10. RASTER ROTATION ERROR

Check +15 / -15V line
NG
・Check SW REG circuit. (see item 13)
OK
Check +5V line
NG
・LC76K on the VIDEO PWB (PWE-567A) failure.
・CN-ASO,CN-DSA failure.
Check if Z-DY voltage varies by
OSM rotate control
NG
Digital control circuit failure (see item 12)
OK
IC4J1,Q4K1and Q4K2 on the DEF PWB (PWE-624)
or its ambient circuit failure.
Make certain that the image position is adjusted when the horizontal
centering control(VR581) on the DEF PWB (PWE-624) is used.
OK
Q581 or C581 may have failed.
NG
Q581, C581 or VR581 on the DEF PWB (PWE-624), C6K1, C6K2 or
D6K1 on the SW/HV PWB (PWE-571) may have failed.
Adjust the raster centering again.
Check the voltage at IC4J1 pin 10 (+14.5V) and pin 5 (-15.6V) on the DEF
PWB (PWE-624).
Check the voltage at CN-DSA pin 7.
The voltage of CN-CR pin1-2 on the DEF PWB (PWE-624)
should be approx. 5.5V.
Measure the voltage at IC532 pin 15 on the DEF PWB (PWE-624).
Normally, the voltage varies from approx. 0V to 5V.