Schedules
(
installer code + [#] + [6] [4]; master code can only access schedules 01-24 and events 00-08 )
Sched
Event
Device No.
No.
(see list
for event
below)
"01":
relays = 01-
16
triggers = 17,
18
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
Events:
Master/Installer
00 = clear event
01 = device on/off
02 = user access
03 = child not home report
04 = forced STAY arm
Start Scheduling mode by entering installer code + [#] + [6] [4] while in normal operating mode.
NOTE: The master code can only access schedules 01-24 and events 00-08.
E N T E R S C H E D N O .
0 0 = Q U I T
0 0
E N T E R E V E N T
NOTE: Events 07 and 10
cause the keypad to beep
every 30 seconds when
messages are displayed.
Stop the beeps by user code
+ OFF.
User
Partition
Start Time/ Days
Group
for events
select days by
"04-06":
entering"1" under
for event
enter 1, 2,
each desired
"02":
or 3
enter 1-8
HH:MM SMTWTFS
05 = forced AWAY arm
06 = auto disarm
07 = display "reminder"
08 = disarm time window
Enter the desired schedule number.
01-24 = end-user schedules
25-32 = installer-only schedules
[∗] to continue
Enter the desired event number for event you want to occur at a specified time.
00 = clear event
01 = Relay On/Off
02 = User Access
03 = Child Not Home Report to Pager (sent to all pagers in the user's partition; message sent is 777-7777;
user must be enabled for paging)
04 = Forced Stay Arming (Forced bypass is automatically enabled regardless of setting in field *23)
05 = Forced Away Arming (Forced bypass is automatically enabled regardless of setting in field *23)
06 = Auto Disarm
07 = Display "Reminder"
08 = Disarm Time Window (system can be disarmed only during this time period. Exception: If a burglary
alarm occurs, the system can be disarmed outside the scheduled time window.
10 = Display Custom Words (installer only; if selected, system displays custom words 8, 9, and 10 at defined
time. Can be used as installer's reminder message to the end user)
11 = Periodic Test Report (installer only)
12 = Up and About (This selection defines the large time window within which the time window selected in
data field *85 will be monitored)
[∗] to continue
Warning
Stop Time/ Days
Delay
select days by
entering"1" under
Time
days desired
01-15 =
minutes
HH:MM SMTWTFS
Installer Only
10 = display reminder words 8-10
11 = periodic test report
12 = up and about
– 18 –
Repeat
Random
enter
0 = no
0-4
1 = yes
(see list
below)
Repeat Options:
0 = no repeat
1 = repeat weekly
2 = repeat every other week
3 = repeat every 3rd week
4 = repeat every 4th week