Honeywell ademco vista-48la Programming Manual page 14

Hide thumbs Also See for ademco vista-48la:
Table of Contents

Advertisement

Start Output Definition mode by pressing ∗ ∗ ∗ ∗ 80 while in Data Programming mode.
Output Funct. #
(00 = Quit)
01
01
A E P Trig
?00 0
0
– ZL=1
01 Activated By:
Zone List
"A"
01 Zn List
1
"B"
01 Enter Zn type
Perimeter
03
"C"
01 Enter Zn No.
12
01 Output Action
Close for 2 sec
1
Enter Output No.
R02
02
02
A E P TRIG
R02 1 1
3
ZL=1
Enter the output function number to be defined
01-48 = output function number
[∗] to continue
00 = exit
This screen displays a summary of the current output programming
A = Output Action; E = Triggering event; P = Partition; Trig = Trigger type
Question mark indicates the device shown has not been mapped. Use *79 Menu mode to map the device.
[∗] to continue
Select where the initiating event for this output definition is to occur.
0 = delete (deletes the output function and any previous programming)
Delete?
To delete this output definition, press 1.
0 = NO, 1 = YES
If you do not want to delete this output,. press 0.
1 = zone list (go to "A" prompt)
2 = zone type (go to "B" prompt)
3 = zone number (go to "C" prompt)
[∗] to continue
If zone list was selected, this screen appears. Otherwise skip to the next row.
Enter the desired zone list number associated with this output number:
01-12 = zone list (Do not use zone lists 09-11 in output definitions if they are being used for paging)
Enter the zone list event that will activate this output:
Enter Event
0 = restore; 1 = alarm;
Alarm
1
2 = fault; 3= trouble
[∗] to continue
NOTE: For alarm, fault, and trouble, an event on ANY zone in the list activates the output, but ALL zones in
the list must be restored before the output is restored.
Press [∗] to continue and skip to the "Output Action" prompt.
If zone type was selected, this screen appears. Otherwise skip to the next row.
Enter the desired zone type for this output number. See list above *80 Worksheet for zone types.
Enter the partition in which this zone type will occur.
01 Partition
0 = any partition; 1 = partition 1;
Any partition
0
2 = partition 2; 3 = partition 3
Press [∗] to continue and skip to the "Output Action" prompt.
If zone number was selected, this screen appears.
Enter the desired zone number associated with this output number.
Press [∗] to continue.
Enter the zone event that will activate this output.
01 Enter Event
0 = restore; 1 = alarm/fault/trouble
Restore
0
Press [∗] to continue to the "Output Action" prompt
Enter the desired device action as listed below.
0 = off
1 = Close for 2 seconds
2 = Close and Stay Closed
3 = Pulse 1 sec ON, 1 sec OFF
Press [∗] to continue.
Enter the device output number (programmed in *79 Menu Mode) you want associated with this output.
01-16 = output no.
17-18 = on-board triggers
Press [∗] to continue.
A summary screen appears showing the programmed settings.
Press [∗] to return to output function number prompt.
4 = Change Device State
5 = Duration 1 (see data field *177 entry 1, from 15 secs to 15 minutes)
6 = Duration 2 (see data field *177 entry 2, from 1 to 7 days)
– 14 –

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents