Panasonic S-07MK2U6 Operating Instructions Manual

Vrf system

Advertisement

* Shows K2 type (Wall Mounted)
Model No.
Indoor Unit
Type
Indoor Unit Type
K2
Wall Mounted
Y2
4-Way Cassette 60x60
 Connectable outdoor unit lineup
This booklet is the operating instructions for indoor unit. Regarding the outdoor unit, see the operating
instructions supplied with the outdoor unit.
Outdoor Units
Type
Outdoor Unit Type
ME2 2WAY VRF System
MF1 3WAY VRF System
LE1 Mini VRF System
* Salt-Air Damage Resistant Specifications.
Before operating the unit, read these operating instructions thoroughly and keep them for future reference.
7
S-07MK2U6
S-09MK2U6
36
52
U-36LE1U6
U-52LE1U6
U-36LE1U6E*
U-52LE1U6E*

Operating Instructions

VRF System Air Conditioner
Nominal Capacity
9
12
S-12MK2U6
S-12MY2U6
Nominal Capacity
72
U-72ME2U9
U-96ME2U9
U-72MF1U9
U-96MF1U9
This air conditioner uses the refrigerant R410A.
18
S-18MY2U6
96
120
U-120ME2U9
144
U-144ME2U9
F569695

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic S-07MK2U6

  • Page 1: Operating Instructions

    VRF System Air Conditioner Model No. Indoor Unit Nominal Capacity Type Indoor Unit Type Wall Mounted S-07MK2U6 S-09MK2U6 S-12MK2U6 4-Way Cassette 60x60 S-12MY2U6 S-18MY2U6  Connectable outdoor unit lineup This booklet is the operating instructions for indoor unit. Regarding the outdoor unit, see the operating instructions supplied with the outdoor unit.
  • Page 2: Table Of Contents

    CONTENTS Page PRODUCT INFORMATION ......................2 ALERT SYMBOLS.........................2 INSTALLATION LOCATION......................3 ELECTRICAL REQUIREMENTS ....................3 SAFETY INSTRUCTIONS......................3 OPERATION CONDITION ......................4 NAMES OF PARTS ........................5 Timer Remote Controller (Optional parts) ..................5 Refer to the Operating Instructions attached to the optional Timer Remote Controller....5 NOTE High-spec Wired Remote Controller (Optional parts)..............5 Refer to the Operating Instructions attached to the optional High-spec Wired Remote...
  • Page 3: Installation Location

    INSTALLATION LOCATION • We recommend that this air conditioner be installed properly by qualified installation technicians in accordance with the Installation Instructions provided with the unit. • Before installation, check that the voltage of the electric supply in your home or office is the same as the voltage shown on the nameplate.
  • Page 4: Operation Condition

    • For safety, be sure to turn the air conditioner off and also to disconnect the power before cleaning or servicing. • Pull off the power plug from a receptacle, or switch off the breaker, or switch off the power disconnecting mean to isolate the air conditioner from the main power supply in case of emergency.
  • Page 5: Names Of Parts

    NAMES OF PARTS INDOOR UNIT Y2 type (4-WAY CASSETTE 60×60) Control Panel Receiver Air is discharged evenly Airflow direction louver Emergency button Intake grille K2 type (WALL MOUNTED) Air filters Front panel Receiver Horizontal airflow Vertical airflow direction louver direction louver •...
  • Page 6: Adjusting Airflow Direction

    ADJUSTING AIRFLOW DIRECTION The functions differ depending on the indoor unit used. The airflow direction cannot be set using the remote controller for any unit which is not listed below. Y2 type, K2 type: • Never use your hands to move the flap (vertical airflow flap) that is controlled using the remote controller.
  • Page 7: Adjusting Airflow Direction For Multiple Indoor Units Using Single Remote Controller (Wired)

    ADJUSTING AIRFLOW DIRECTION (CONTINUED) 4-way cassette (Y2) Y2 type air conditioner is equipped with auto flaps. You can set the airflow direction to a specific angle or to the sweep mode using the remote controller. Do not move the flap with your hands. Wall mounted type (K2) Vertical directions (automatic) Confirm that the remote controller has been turned on.
  • Page 8: Special Remarks

    SPECIAL REMARKS ‘‘DRY’’ Operation • Once the room temperature reaches the level that was set, the unit repeats the cycle of How it works turning on and off automatically. • In order to prevent the humidity in the room from rising again, the indoor fan also turns off when the unit stops operating.
  • Page 9 • Switch off the power supply before cleaning. • Do not touch the aluminium fin, sharp parts may cause injury. HINTS CLEANING INSTRUCTIONS • Clean the filter regularly for best performance • Do not use benzene, thinner or scouring powder. and to reduce power consumption.
  • Page 10: Troubleshooting

    TROUBLESHOOTING If your air conditioner does not work properly, first check the following points before requesting service. If it still does not work properly, contact your dealer or a service center. INDOOR UNIT Symptom Cause Noise Sound like streaming water during •...
  • Page 11: Check Before Requiring Services

    CHECK BEFORE REQUIRING SERVICES Symptom Cause Remedy Air conditioner does not run at Power failure or after power failure Press ON/OFF operation button on remote controller all although power is turned again. Operation button is turned off. • Switch on power if breaker is turned off. •...
  • Page 12: Specifications

    Net Weight* 45.3 (20.4) 45.3 (20.4) lbs. ( ㎏ ) * Values include the dimensions and weight of an optional ceiling panel. Wall Mounted Model Name S-07MK2U6 S-09MK2U6 S-12MK2U6 Power Source 208 / 230 V, 60 Hz, 1PH BTU/h 7,500...
  • Page 13 MEMO...
  • Page 14 MEMO...
  • Page 15 MEMO...
  • Page 16 © Panasonic Corporation 2014 F569695 BE0414-10814 Printed in Malaysia...