Kenwood TK-2402(V) Service Manual page 28

Hide thumbs Also See for TK-2402(V):
Table of Contents

Advertisement

TK-2402(V)/2402/2406/2407
Item
Condition
6. DQT
1) TEST CH: Center
Deviation
2) Deviation meter fi lter
*Note
LPF: 3kHz
HPF: OFF
3) PTT: ON
7. QT
1) TEST CH: Center
Deviation
2) Deviation meter fi lter
*Note
LPF: 3kHz
HPF: OFF
3) PTT: ON
8. DTMF
1) TEST CH: Center
Deviation
2) Deviation meter fi lter
*Note
LPF: 15kHz
HPF: OFF
3) PTT: ON
9. MSK
1) TEST CH: Center
Deviation
2) Deviation meter fi lter
*Note
LPF: 15kHz
HPF: OFF
3) PTT: ON
*Note (for the Max Dev, DQT Dev, QT Dev, DTMF Dev and MSK Dev):
1) If select the item without (Wide) or (Narrow), the alignment will be align according to Narrow Band. Wide band will automatically update by
calculation using Narrow band value.
2) If select the item with (Wide) or (Narrow),
(a) If wide band is selected, the alignment only will be done for wide band.
(b) If Narrow band is selected, the alignment only will be done for Narrow band.
Receiver Section
Item
Condition
1. Sensitivity
1) TEST CH: Low, Center, High
(Semiauto-
(3 points)
matic)
SSG otuput : –90dBm
AF Freq : 1kHz
Mod Dev : 1.5kHz
28
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Deviation
ANT
meter
Oscilloscope
Measurement
Test-
Unit
Terminal
Unit
equipment
SSG
ANT
Oscilloscope
Audio
Analyzer
Adjustment
Parts
Method
FPU
0.35kHz
±40Hz
0.35kHz
±40Hz
1.5kHz
±50Hz
1.5kHz
±50Hz
Adjustment
Parts
Method
FPU
Press [Start]
(Auto tuning)
Specifi cations / Remarks
Specifi cations / Remarks