[1]
7) Hold the tab (the bend) [A] of the mirror stay to move the No. 1 mirror
base [1] to the left until it stops.
8) Insert the cable clamp [1] to the hole [2] of the frame.
9) Attach the lens heater [1]
- 1 connector [2]
- 1 cable clamp [3]
- 1 screw (RS tightening; M4X8) [4]
Tighten the screw [3] while pushing on the lens heater [1] in the direction
of the emboss [2]. Be sure that the heater's claw [4] must not be disengaged
when performing this operation. Also check that the bottom of the heater
must not be off from the board.
[2]
F-2-106
[1]
[A]
F-2-107
F-2-108
F-2-109
10) In case that the cable [1] is loose, insert the cable clamp [2] to the frame's
hole to fix the cable in place.
[1]
11) By reversing the steps used to remove, attach the copyboard glass and
the glass retainer.
12) Close the DADF.
13) Shift the cassette heater switch [1] and the environment switch [2] to the
on position.
[1]
O N
[2]

2.10 Installing the Cassette Heater

2.10.1 Checking Components

iR5065 / iR 5055 / iR5075 / iR5075N / iR5065N / iR5055N
<Cassette Heater>
Chapter 2
[2]
[4]
[3]
[1]
F-2-110
[2]
F-2-111
F-2-112
0015-7889