Emptying the boiler Tank
Warning: While the boiler is being emptied, the machine must be unplugged. The boiler may be
emptied only when the bowl is empty and the machine has cooled down sufficiently.
Remove the drip tray
Remove the cap (A) (Fig 31)
Place the machine on a flat surface
Place a container (B) with a capacity of more
than 3 litres underneath the bleeder cap (C)
Use a coin or Allen wrench to unscrew the
bleeder cap (C )
Pull out the cap (C ) with a firm movement
and wait for all the water to empty out from
the boiler tank (Fig 32)
Cleaning and de-scaling the Boiler Tank
Warning: The boiler tank needs to be de-scaled on a regular basis
Follow the steps for draining out the boiler tank
Insert and secure the boiler tank bleeder cap
Fill the boiler tank with a solution of scale remover (suitable for use in coffee machines) and
water (following instructions supplied with the scale remover)
Leave the solution in the tank for the time indicated in the scale remover instructions
Empty out the solution from inside the boiler tank
Rinse out the tank as per scale remover instructions