10.5.2 Setting the exposure

38
Siemens Building Technologies
Fire Safety & Security Products
Open the unit's home page. See Section 7.4 Accessing the unit's home page.
1.
In the Configuration menu, select the menu option Camera and the
2.
Exposure Settings suboption.
The Exposure Settings dialog will appear:
Fig. 8
Exposure settings
Enter the desired settings in this dialog.
3.
Operating mode
Shutter
Level
Click Save.
4.
Set the exposure level here.
The following options are available:
ALC
Automatic aperture control
ELC
Electronic shuttering
This will set the electronic high-speed shutter (AUTO to 1/100,000 s).
Select a shutter speed from 1/50 to 1/100,000.
NOTE
ELC mode is intended for the use of lenses with manual aperture
setting.
Select a level from 0 to 9 for adaptation of the individual picture
brightness for the ALC and ELC operating modes.