Sharp IV-S30J User Manual page 206

Compact image sensor camera
Table of Contents

Advertisement

(3) How to specify the output conditions for ladder circuit diagrams
Move the cursor to "OUT" and press the SET key. Select a target for the output signals from the
popup menu. Detail of the registration table that will appear varies, depending on the target selected
for output.
When "OUTPUT Y" is selected
OUTPUT COND
SCREEN SAVE
INPUT00-07
CHANGE INPUT
INPUT00
LOGIC
INPUT01
LOGIC
AUX-RLY
INPUT02
LOGIC
Y
INPUT03
Y
LOGIC
Y
INPUT04
Y
LOGIC
Y
INPUT05
Y
LOGIC
Y
INPUT06
Y
LOGIC
INPUT07
LOGIC
SET=SELECT OUTPUT RELAY SEC=BACK SEL=CHNG IMG TRG=FUNC
When "TMR TM" is selected
OUTPUT COND
SCREEN SAVE
INPUT00-07
CHANGE INPUT
INPUT00
LOGIC
INPUT01
LOGIC
TM TIME REG
INPUT02
LOGIC
TM
INPUT03
TM
LOGIC
TM
INPUT04
TM
LOGIC
TM
INPUT05
TM
LOGIC
TM
INPUT06
TM
LOGIC
INPUT07
LOGIC
SET=SELECT OUTPUT RELAY SEC=BACK SEL=CHNG IMG TRG=FUNC
Creation example:
INPUT00
LOGIC
F C1 BRT
OUT
OUTPUT Y
AUX-RLY-C
Use place
TMR TM
NO
CNTR CN
NO
DEL
NO
NO
NO
NO
NO
NO
F C1 BRT
OUT
OUTPUT Y
AUX-RLY-C
Use place
TMR TM
CNTR CN
NO
DEL
NO
NO
NO
NO
NO
NO
NO
15-13
When "AUX.RLY-C" is selected
OUTPUT COND
SCREEN SAVE
INPUT00-07
CHANGE INPUT
INPUT00
LOGIC
INPUT01
LOGIC
Y OUTPUT
Use place
INPUT02
LOGIC
C
NO
INPUT03
C
NO
LOGIC
C
NO
INPUT04
C
NO
LOGIC
C
NO
INPUT05
C
NO
LOGIC
C
NO
INPUT06
C
NO
LOGIC
INPUT07
LOGIC
SET=SELECT OUTPUT RELAY SEC=BACK SEL=CHNG IMG TRG=FUNC
When "CNTR CN" is selected
OUTPUT COND
SCREEN SAVE
INPUT00-07
CHANGE INPUT
INPUT00
LOGIC
INPUT01
LOGIC
TM TIME REG
Use place
INPUT02
LOGIC
CN
NO
INPUT03
CN
NO
LOGIC
CN
NO
INPUT04
CN
NO
LOGIC
CN
NO
INPUT05
CN
NO
LOGIC
CN
NO
INPUT06
CN
NO
LOGIC
INPUT07
LOGIC
SET=SELECT OUTPUT RELAY SEC=BACK SEL=CHNG IMG TRG=FUNC
PC Function
F C1 BRT
OUT
OUTPUT Y
AUX-RLY-C
TMR TM
CNTR CN
DEL
F C1 BRT
OUT
OUTPUT Y
AUX-RLY-C
TMR TM
CNTR CN
DEL
15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents