Telephone Button Programming
300 Series Programs
Table 1-28
Programs 303~315 (continued)
Button
Sequence
306-18
Network COS
FB18
Hold
, n,
307
OLG Delete
307
Hold
,
307-00
OLG Number
Hold
Hold
n,
,
308
Trunk Timers
308
Hold
,
308-00
Trunk Equipment No.
Hold
xxyyzz,
308-01
Auto Release
FB01
Hold
, n,
308-02
Short Flash
FB02
Hold
, n,
308-03
Long Flash
FB03
Hold
, n,
308-04
Pause after Flash
FB04
Hold
, n,
308-04
Response Timer
FB05
Hold
, n,
309
Direct Inward Dialing
309
Hold
,
309-00
ILG Number
Hold,
n,
309-01
DID Number
FB01
Hold
, n,
1-60
Value(s)
n =
1~32
(default = 1)
Hold
,
n =
1~32 (CTX100)
1~50 (CTX670 Basic)
1~128 (CTX670 Exp.)
xx =
Cabinet 1 (CTX100),
01~02 (CTX670 Basic),
01~07 (CTX670 Exp.)
yy =
Slot 01~8 (CTX100),
01~10 (CTX670)
zz =
Circuit 01~24
n =
1. Disable
2. Detect 95ms
,
3. Detect 450ms (default)
n =
0~15, where 1 = 100msec.
(default = 5, which is .5
,
seconds)
0 = no flash
n =
0, 5, 10, 15, 20, 25 and 30,
where 5 = .5 seconds.
(default = 20)
n =
0~5, 0 = immediately sent,
and 1sec.delay to
5sec.delay
(default = 1 second delay
before sending digits)
n =
0~3000
n =
1~32 (CTX100)
1~50 (CTX670 Basic)
1~128 (CTX670 Exp.)
n =
1~7 digits may include wild
card ì?î where ì?î = 0~9
Summary
Select Network COS number.
This command deletes Outgoing Line Groups.
Enter the OLG number to delete.
Assigns trunk timers for analog and T1 trunks.
Enter the trunk equipment number.
Note
Equipment numbers are required when assigning a new trunk
to the system. It can also be used to display the equipment
location of existing trunks.
Select the Automatic Release timing.
Note
Select Disable if the CO does not send the automatic release
signal to the loop start trunk.
Select Short Flash Time. When a telephone initiates the short flash
signal to the CO line it is connected to (using the short Flash feature
button or access code #450) the duration of a short flash is
determined by this command. Normally this signal is used to hook
flash a centrex line. The short flash range is 0 to 1.5 seconds in
increments of 0.1 seconds.
Select Long Flash Time. When a telephone initiates the long flash
signal to the CO line it is connected to (using the Long Flash feature
button or access code #451) the duration of a long flash is determined
by this command. Normally this signal is used to disconnect the line.
The long flash range is 0 to 3 seconds in increments of 0.5 seconds.
Pause time after flash: After a flash signal is sent to a CO line, this
timer determines when the line will start to send the dialed digits to
the other end.
The response timer is for analog DID/TIE lines that have the ìstart
methodî set for ìTimingî in Program 300-06. After a line is seized this
timer determines when the line will start to send the dialed digits to
the other end.
Possible Values 0=immediatly sent, and 50msec.delay to
500msec.delay. (default=500mseconds delay before sending digits).
This command assigns DID Number Analysis Table to ILG.
Select the ILG number.
Enter a DID number.
Strata CIX/CTX Telephone Button Programming 11/04