39
5.8
Recording measurements
Screen
en
Desktop software: SFE tool as a file for download
Action steps
Navigate to the Graph (1) tab.
If necessary, adjust the DISPLAY
DURATION (2) and REFRESH RATE of the
display (3).
Note
If the checkbox at "Auto Range (Y)" (4)
is activated, the minimum and maximum
values of the Y axis are adjusted to the
current measurement.
Use the checkboxes (5) to select the signals
that should be displayed. You can choose
from:
• X[mm]: Deflection in X direction in mm
• Y[mm]: Deflection in Y direction in mm
• Z[mm]: Deflection in Z direction in mm
• Rx[°]: Deflection in Rx direction in °
• Ry[°]: Deflection in Ry direction in °
• Rz[°]: Deflection in Rz direction in °
• CalcTime[ms]: Required time for calculating
the measured values in mm/° from the raw
values
• D1[raw]: Raw value sensor 1 in counts
• D2[raw]: Raw value sensor 2 in counts
• D3[raw]: Raw value sensor 3 in counts
• D4[raw]: Raw value sensor 4 in counts
• D5[raw]: Raw value sensor 5 in counts
• D6[raw]: Raw value sensor 6 in counts
• Temperature[°C]: Actual temperature in °C
• Acceleration X [g]: Actual acceleration value
in X direction in g (=9.81 m/s2)
• Acceleration Y [g]: Actual acceleration value
in Y direction in g (=9.81 m/s2)
• Acceleration Z [g]: Actual acceleration value
in Z direction in g (=9.81 m/s2)
The selected measured values appear in the
recording area including the color of the
graph in the form of a key (6).
Click Start (7) to start the measurement.
5