Motorola DIMETRA MTS 2 Installation, Configuration And Basic Service Manual page 403

Hide thumbs Also See for DIMETRA MTS 2:
Table of Contents

Advertisement

MTS 2 and MTS 4 Installation, Configuration and Basic Service Manual
Table 13-7 Generic Base Radio Alarms (Continued)
Alarm ID
ALM_RX2_PATH
ALM_RX3_PATH
6802800U74-N September 2009
Recovery
Description
Action
RSSI for
No recovery
action taken by
Receiver path
the software.
2 is much
lower than
maximal RSSI
measured for
the remaining
configured
paths.
No recovery
RSSI for
action taken by
Receiver path
3 is much
the software.
lower than
maximal RSSI
measured for
the remaining
configured
paths.
Base Radio Alarms
Clear Action
mand can be used for
checking the thresh-
old that is currently
used. The alarm may
be reported because
of the BRC hardware
failure or configura-
tion problems.
When the clear
Each time when RSSI
condition is met
for path 2 is less than
then the alarm is
(max_RSSI - mts_re-
cleared.
ceive_path_thresh-
old) then RSSI failure
counter for path 2
is incremented by 1.
Otherwise the counter
is decremented by 2.
After checking the
alarm condition the
counter is set to 0 if it
has a negative value.
The 'rssicnt' com-
mand can be used for
checking the thresh-
old that is currently
used. The alarm may
be reported because
of the BRC hardware
failure or configura-
tion problems.
When the clear
Each time when RSSI
condition is met
for path 3 is less than
then the alarm is
(max_RSSI - mts_re-
cleared.
ceive_path_thresh-
old) then RSSI failure
counter for path 3
is incremented by 1.
Otherwise the counter
is decremented by 2.
After checking the
alarm condition the
counter is set to 0 if it
has a negative value.
The 'rssicnt' com-
mand can be used for
checking the thresh-
old that is currently
used. The alarm may
be reported because
Notes
13-37