Polaris RZR XP 1000 2014 Service Manual page 102

Table of Contents

Advertisement

ENGINE / COOLING SYSTEM
14. Install a NEW mechanical seal into the water pump
housing using special tool (PU-50564)
new mechanical seal in until it is flush with the water
pump housing.
15. Rotate water pump shaft after seal installation to
verify free movement.
16. Place impeller onto the water pump shaft.
17. Apply Loctite
®
204
bolt. Install washer and impeller bolt and torque to
specification.
TORQUE
Water Pump Impeller Bolt:
7 ft-lb (10 Nm)(Apply Loctite® 204™ to bolt threads)
q
18. Clean cover
and housing gasket surfaces
19. Install a new water pump cover gasket
3.24
u
. Press the
to the threads of the impeller
w
e
.
20. Install the water pump cover and three retaining bolts
i
. Torque bolts in sequence to specification.
7 ft-lb (10 Nm)(Apply Loctite® 204™ to bolt threads)
21. Install two new water pump (O-rings) and lubricate
them with fresh engine oil.
.
9926816 R07 - 2014-2016 RZR XP 1000 / XP4 1000 Service Manual
TORQUE
Water Pump Cover Bolts:
© Copyright Polaris Industries Inc.

Advertisement

Table of Contents
loading