Toshiba V Series User Manual page 118

Integrated controller
Hide thumbs Also See for V Series:
Table of Contents

Advertisement

Appendix C Table of Trace Information
No.
Event
Level
0E05
Temperature
Recovery
abnormality
from
corrected
failure
Registration
7000
Packing
Caution
discontinued
(Instance
memory
management
error)
7001
Packing
Caution
discontinued
(Entry code
memory
management
error)
7002
Packing
Caution
discontinued
(POU code
memory
management
error)
D005 Batch
Major
download not
failure
conducted
User-program-related
D100 User task
Major
stop illegal
failure
instruction
detected
D102 User task
Major
stop
failure
boundary
over
D104 User task
Major
stop POU
failure
number
undefined
C
D106 User task
Major
stop
failure
arithmetic
stack error
7108
User task
Caution
real-number
arithmetic
error
7109
User task
Caution
boundary
error
710C User task
Caution
division error
710D User task
Caution
BCD
conversion
error
710E
User task
Caution
table
operation
error
710F
User task
Caution
encode error
7112
User task
Caution
non-numeral
input
104
Execution
Timing
Diagnosis
status
Periodical
Continued
Temperature
diagnosis
abnormality
around CPU has
been corrected.
Continued
Inconsistent
instance memory
management has
been detected.
Continued
Inconsistent entry
code memory
management has
been detected.
Inconsistent POU
code memory
management has
been detected.
Startup in
Error rundown
Batch download
RUN mode
of application
program has not
been conducted.
During user
Error rundown
Instruction nor
task
defined in user
execution
program has been
detected.
During user
Error rundown
Specified user
task
task size is
execution
exceeded.
During user
Error rundown
Designated
task
function block or
execution
function is not
found.
During user
Error rundown
Number of
task
outputs from stack
execution
is inconsistent is
inconsistent with
the number of
inputs.
During user
Continued
Improper real-
task
number arithmetic
execution
operation has
been executed.
During user
Continued
Access has been
task
made to the area
execution
outside variable
domain.
During user
Continued
Division by 0 has
task
been executed.
execution
During user
Continued
BCD conversion
task
has gone beyond
execution
data range.
During user
Continued
Error has
task
occurred in
execution
handling a table,
such as LP_PARA
or PV_DATA.
During user
Continued
Limit error has
task
occurred in
execution
encoding.
During user
Continued
Non-numeral has
task
been input by
execution
real-number
arithmetic
instruction.
Task
Address
Aux1
Aux2
Block
Number of
Entry serial
number
blocks
number (0
to 308)
Block
Number of
Entry serial
number
blocks
number (0
to 308)
Block
Number of
POU
number
blocks
number (0
to 2047)
IP (Absolute) IP
IR
(Relative)
IP (Absolute) IP
IR
(Relative)
IP (Absolute) IP
IR
(Relative)
IP (Absolute) IP
IR
(Relative)
IP (Absolute) IP
IR
(Relative)
IP (Absolute) IP
IR
(Relative)
IP (Absolute) IP
IR
(Relative)
IP (Absolute) IP
IR
(Relative)
IP (Absolute) IP
IR
(Relative)
IP (Absolute) IP
IR
(Relative)
IP (Absolute) IP
IR
(Relative)
model 3000 Loop Controller L3 User's Manual - Basic Hardware -
Aux3
Cause
Actions to be taken
After memory clear,
Conduct batch downloading of
RUN command has
applicable application from
been entered before
engineering tool.
batch downloading of
program from
engineering tool.
Failure of memory
Clear memory of L3 controller,
and download program again.
Failure of memory
Clear memory of L3 controller,
and download program again.
Function block or
Set POU number of function
function has not been
block or function in the normal
downloaded, or POU
range (2048 to 4095), carry out
number is incorrect.
compilation using a caller
project, and download compiled
program.
Compilation is not
After completing compilation
normal.
normally, download compiled
program.
For real-number
Review values input for real-
arithmetic operation,
number arithmetic operation,
an improper value
and correct user task so that
that cannot be
improper values are not input.
calculated, such as -
1^0.5 (the 0.5th
power of -1), has
been input.
For symbols of IL, ST,
Correct structural variable name
relay, coil, etc.,
positions, indexing positions,
structure variable
etc. that are out of the variable
names, array variable
domain, and download program.
names, and/or
indexing are used,
their positions being
out of the variable
domain.
In division instruction,
Correct user task so that divisor
divisor is set to 0.
is not set to 0, and download
program.
In integer-to-BCD
Correct user task so that input
conversion, input
value does not exceed limit, and
value exceeds the
download program.
limit (INT type: 9999,
DINT type:
99999999). In BCD-
to-integer conversion,
certain digit of input
value exceeds the
limit value (9).
Address for
Review and correct table-
designating a table,
designating address, and
such as LP_PARA or
download program.
PV_DATA, is out of
range.
By real-number
Correct user task so that non-
arithmetic instruction,
numeral is not input, and
an inoperable value,
download program.
such as infinite (Åá)
value (± 1.#INF), has
been input.

Advertisement

Table of Contents
loading

This manual is also suitable for:

3000

Table of Contents