SIMOCRANE CeCOMM commissioning and diagnostic program
8.5 Monitor (tab)
In addition to allowing processing of current parameter sets, the file manager in the
SIMOCRANE CeCOMM diagnostic program also enables users to access and edit the four
saved text files (parameter files).
These text files are located on the CF card of the SIMOTION D4x5-2 DP/PN in the
SWAYCONTROL directory.
8.5.3.2

Call and navigation in the parameter menus

Parameters are entered and processed via the main menu or via another display screen. The
parameter menu is called by pressing "P." The parameter menu contains an overview of the
parameter groups that can be displayed by page in short form with the keys "1", "2", etc.
Parameters which are not set to their default settings are identified by a "+" sign. When "?" and
the parameter number are entered, a detailed explanation of the parameter is displayed
together with the current value and the default, minimum and maximum values.
The parameter can be changed with "C" and the parameter number. Only values in the range
between the fixed minimum and maximum values can be entered for the parameter.
If values lower than 20 are input as settings for the acceleration parameters, they will be
interpreted as ramp times and made available for transfer after conversion to the corresponding
acceleration values.
Note the following:
● Always use the parameter menu of the SIMOCRANE CeCOMM diagnostic software in order
to edit the parameter sets as this is the only method which guarantees a plausibility check
on the file and ensures that input errors will be rejected.
If you directly edit the stored text files (e.g. Par0.txt) instead, they will not be checked for
plausibility and the entire file could be rendered unusable as a result.
● If the acceleration parameters are set to values less than 20 directly in the text files, these
will not be interpreted as ramp times but as acceleration values.
Detailed information about the parameters is contained in Chapter Parameters (Page 393) and
the online help.
8.5.3.3

Activating a parameter set

The active parameter set can be changed via the IPARSET input of the DCC_SCCOMMON
block.
284
SC integrated STS, GSU
Operating Instructions, 07/2019, A5E48271265B AA